Simplex 4100ES Fire Control Panels

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4100es-fire-control-panels-8945370162.pdf
Type PDF
Size 888.56 KB
Downloads

Text Preview

ULC CSFM Listed Approved Series MINIPLEX transponders allow located initiating and notification Transponder operation is available as standard or with mode operation Communications with the host fire alarm control panel the Remote Unit Interface RUI RUI format functions include Addressable device support including TrueAlarm sensor compatibility Conventional initiating device circuit IDC support functions include Addressable strobe and horn notification using power delivery IDNAC SLCs Emergency voice alarm communications Conventional DC notification appliance circuits NACs mode operation provides Default local initiating and notification operation in the of a communications loss with the host control panel Enabling of an optional Local Mode Controller with a alarm sounder LED status indicators and enabled control switches Support for IDNet addressable devices addressable and notification appliances and default output from local amplifiers modules include Digital or Analog audio riser modules for connection to Digital or analog input audio amplifiers with integral audio signals NACs Power supplies with or without battery chargers City Connect modules and RS 232 ports for printers or terminals Alarm relays auxiliary relays additional IDC modules NAC expansion modules are equipped with solid doors beige or and in one two or three bay sizes to UL Std 864 Fire Detection and Control UOJZ and Control Service UUKL UL Std 2017 Process Management Equipment QVAX UL Std 1076 Proprietary Alarm Units Burglar APOU UL Std 1730 Smoke Detector Monitor UULH ULC Std S527 99 See pages 4 and 5 for product that is listed as UL or ULC This product has been approved by California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health Safety Code See CSFM Listing 7165 0026 0251 for allowable values and or conditions material presented in this document Additional listings may be applicable contact local Simplex product supplier for the latest status Listings and approvals under Simplex Recorder Co are the property of Tyco Fire Protection Products Fire Control Panels Addressable Fire Detection and Control Transponders addressable DOWN strobes IDNAC SLC NAC Alarm Local Mode Controller mode IS C ON NEC T POWE R D A TTE RY EFORE RV IC ING POWER B C ONE1 K L T U SP T E F IG2 N O W X 0 H I Q R t Z S A larm Pr iority 2 Ala rm WARNINGS ble isory Silenced Power A larm k rity 2 v vent ime sable f rm uto ext or Warning Condition indi cator flashing Tone On to Ac knowledge View Events ACK located under flashing indicator oper ation until all events are acknowledged t one will silence to Silenc e Building Signals Alarm Silence to Reset System System Reset Ack to silence to ne de vice Operating Instructions Fire Alarm Control Panel Voice Control 4100ES MINIPLEX System One Line Drawing MINIPLEX transponders connect to a host Fire Alarm Control Panel using Simplex remote interface RUI communications At the transponder communications are received by the transponder module and translated into the same internal format that is used in the host control located modules With RUI the transponder can remotely provide same initiating and notification functions that occur at host control panel without requiring multiple long wiring runs Connections to the host panel are current communications and audio wiring with up to 2500 ft 762 m Reference Refer to document S4100 0100 the other documents listed on page 3 for additional concerning the extensive initiating and features of the 4100ES fire alarm control 5 2013 Module Bay Description model 4100 9600 includes a bay a power distribution interface module PDI a Transponder Interface Module and an interconnect Communications with the host fire alarm control are via a Remote Unit Interface RUI connection allows for up to 2500 ft 762 m distance RUI can with up to a total of 31 remote devices and be either Style 4 or Style 7 communications model 4100 9601 substitutes a Local Transponder Module for the Basic Transponder Expansion Bays each include a PDI and a variety of optional modules refer to list starting page 4 Battery Compartment bottom accepts two up to 50 Ah that can be mounted within the Battery mounting does not interfere with module space A power supply with battery is required for each battery set Availability Modules are power limited except as noted such as modules Enclosure are available for one two or three bay sizes for cabinet rack mounting Boxes and solid doors are available in beige or red separately Up to eight close nippled cabinets can be connected at transponder location close nippled is mounted 20 ft 6 m and with interconnecting wiring in conduit Refer to document S4100 0037 for enclosure details Mode Control Operation Stand Alone Operation In the event of a loss with the host fire alarm control model 4100 9601 MINIPLEX Local Mode provide fire alarm response default for its connected devices and appliances per the Operation During local mode operation initiating devices connected to the transponder cause an alarm at their least sensitive alarm threshold Photoelectric sensors will alarm at 3.7 ft smoke sensors will alarm at 1.3 ft obscuration Heat sensors will alarm at a fixed temperature of 135 F TrueAlarm device LEDs will be activated to indicate a C in alarm Local Mode Control Operation Continued Operation Fire alarm conditions reported a fire alarm point type within a transponder in mode will cause all notification appliance circuits in transponder to Sound a general alarm temporal pattern horn tone Activate visible notification appliance circuits Mode Module Support Local mode operation support for the following 4100ES modules Enhanced Power Supplies EPS EPS including IDNAC SLCs 1 addressable device circuits including those the EPS IDNet 1 expansion modules and Quad IDNet Isolator Module Expansion Power Supplies XPS including on board and expansion signal modules operated at a pattern 4100ES amplifiers will provide their on board horn tones Hz at a temporal pattern through their on board NACs Firefighter Telephone control modules in local mode Mode Operation Module Exclusion Modules listed above but that are listed as compatible with transponders per this document do not with local mode operation but are not supported local mode operation Mode Controller During local mode operation an optional Mode Controller will indicate status see illustration and can be enabled using a keyswitch to perform alarm silence or reset If alarms occurring during local are reset using a Local Mode Controller upon of communications those alarms will not be to the master controller If alarms are still present restoration of communications then the alarm

Related Files