Simplex 4100ES Fire Control Panels Addressable Fire Detection and Control

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Approved Controller top bay standard equipment 32 Bit Master Controller with color coded operator and raised switches for high confidence feedback Dual configuration program CPU convenient service port and capacity for up to 2500 addressable points CPU assembly includes 2 GB dedicated compact flash for on site system programming and information An Enhanced Power Supply EPS and battery charger A total with on board IDNAC SLCs signaling line for addressable appliance control IDNet 1 addressable device control channel and function auxiliary output Also available with InfoAlarm Command Center expanded user interface see data sheet S4100 0045 addressable device interfaces include 1 250 point addressable device SLC supports analog sensors and IDNet communications and control devices and operates with output for use with either shielded or unshielded or untwisted single pair wiring MINIPLEX Transponder and remote LCD and LED support via RUI remote unit interface port with isolated output for use with shielded or unshielded twisted or untwisted single wiring EPS power supplies provide enhanced delivery IDNAC SLCs to addressable appliances With IDNAC SLCs a constant 29 VRMS source voltage is even during battery standby allowing strobes operate at higher voltage with lower current and ensuring consistent current draw and voltage drop margin under primary power and secondary battery standby Efficiencies include lower strobe currents wiring distances to 2 to 3 times farther than with conventional support for more appliances per IDNAC SLC to use smaller gauge wiring all providing and maintenance savings with high assurance that operate during normal system testing will during worst case alarm conditions SLCs are compatible with both TrueAlert ES and addressable notification appliances and remote IDNAC Repeaters to extend power and wiring even farther modules and connections include Fire Alarm Network Interfaces city connections and up five 5 RS 232 ports for printers and terminals Building Network Interface Module BNIC for Ethernet options see data sheet S4100 0061 Side mounted DACT assembly requiring minimal panel DACT is compatible with IP Communicators Emergency communications systems ECS equipment channel digital audio or 2 channel analog audio 4100ES Fire Control Panels Addressable Fire Detection and Control Panel Modules and Accessories B C K L T U E F G N O W X 0 H I UX Q R DNet Z Alarm Priority 2 Alarm WARNINGS Silenced Power Alarm 2 or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions B C K L T U ET E F G N O W X 0 H I UX Q R DNet Z Alarm Priority 2 Alarm WARNINGS Power Silenced Alarm 2 or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions Cabinets are Available with Two or Three Bays Modules Continued Additional IDNet 1 addressable device communications and IDNet quad output isolator modules power supplies alarm relays and auxiliary LED switch modules and panel mount printers VESDA Aspiration Systems interface ASHRAE BACnet TCP IP Bridges Battery brackets for seismic area protection see page 2 4100ES compatible legacy interface modules control of conventional non addressable see data sheet reference list on page 8 Listings reference UL Std 864 Fire Detection and Control UOJZ and Control Service UUKL UL Std 2017 Process Management Equipment QVAX UL Std 1076 Proprietary Alarm Units Burglar APOU UL Std 1730 Smoke Detector Monitor UULH ULC Std S527 Control Units for Fire Alarm Systems Feature Summary provides dual configuration programs Two programs allow for optimal system protection and efficiency with one active program and reserve downtime is reduced because the system running during download based programmer features Convenient front panel accessed Ethernet port for quick easy download of site specific programming Modifications can be uploaded as well as downloaded for service flexibility AND firmware enhancements made via software downloads to the on board flash See pages 7 and 8 for product that is UL or ULC listed and additional listing information This has been listed by the California State Fire Marshal CSFM pursuant to Section of the California Health and Safety Code See CSFM Listing 7165 0026 0251 for values and or conditions concerning material presented in this document listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products 5 2013 Introduction 4100ES Series Fire Detection and Control Panels extensive installation operator and service features point and module capacities suitable for a wide range of applications An on board Ethernet port provides fast system communications to expedite installation and activity Dedicated compact flash memory archiving secure on site system information storage of job configuration files to meet NFPA 72 National Alarm and Signaling Code requirements design A wide variety of functional modules are to meet specific system requirements Selections panels to be configured for either Stand Alone or fire control operation Module Bay Description The Master Controller Bay top includes a standard enhanced power supply EPS the master board two vertical expansion blocks and operator equipment Expansion Bays include a Power Distribution PDI for connection of single or multiple block and or slot style motherboard daughter card Battery Compartment bottom accepts two up to 50 Ah to be mounted within the cabinet interfering with module space DACT location Controller Bay 1 2 3 4 board with two available controller with slot motherboard Bay 1 1 2 3 4 5 6 7 8 Wiring Wiring 4190 6104 Module location Power Supply IDNet 1 Module Module E Module F Wiring Module E Module F Wiring Power G H Power G H bays with module sizes 1 2 3 4 5 6 7 8

Related Files