Simplex 4100ES Fire Control Panels; Microphone Multiplex Module Model 4100-1274

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance additional remote microphones to a 4100ES or 4100U fire alarm audio panel Each 4100 1274 Microphone Multiplex Module a single microphone input to support up to 8 remote microphones Up to 40 remote microphones can be connected per controller see compatibility below Allows additional remote microphones for such as UFC Unified Facilities Criteria for Mass Notification systems for Navy Air Force requiring a microphone interface within ft 61 m of travel within a building Refer to UFC 4 021 01 9 April 2008 for details Remote microphones and associated controls specific operation and enclosure requirements this document Connect one 1 4100 1274 to the remote microphone of either a Digital Audio Controller Model or 4100 1211 or an Analog Audio Model 4100 1210 Connect up to two 2 4100 1274 Microphone Modules to a 4100 1240 Auxiliary Audio Module inputs 3 and 4 Up to two 2 4100 1240 modules are supported per controller microphones Model 4100 1244 panel mounted microphone in Remote Annunciator Model 4003 9803 remote microphone with control wiring connections to a 24 Point I O Module 4100 1290 in the audio control panel Other compatible standard or noise cancelling each microphone on a 4100 1274 needs to be the same type details remote microphone wiring and PTT switch wiring is monitored by the module An on board IDNet Supervised IAM monitors module requires one IDNet address and one unit load On board module diagnostic LEDs indicate Open Earth Earth per microphone IAM LED communication status with fire alarm control On board earth detection circuit UL Listed to Standard 864 Control Panels Multiplex Module 4100 1274 TALK TALK TALK TALK TALK TALK B C ONE K L B T U SP E F N O W X 0 H I UX Q R Net Z Alarm Priority 2 Alarm WARNINGS Silenced Power Alarm 2 xt or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions Audio System with 4100 1274 Microphone Module and 8 Remote Microphones 6 Model Remote Microphones and 2 single bay Annunciators with Remote Microphone Remote Microphones Standard 4100ES 4100U Audio systems support up to five 5 remote For applications requiring more convenient to remote microphone control the 4100 1274 Multiplex Module allows up to eight 8 microphones to connect to each standard remote input to 40 Remote Microphones With two Auxiliary Audio Input Modules connected five total 4100 1274 Microphone Multiplex Modules total of 40 Remote Microphones are supported This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Accepted for use City of New York Department of Buildings MEA35 Additional listings may be applicable contact your local Simplex product supplier for latest status Listings and approvals under Simplex Time Recorder Co are the of Tyco Safety Products Westminster 4 2013 Product Selection Multiplex Module Microphone with on off switch and ready to talk LED control wiring connects to a 4100 1290 24 Point module in the audio control panel Instruction Reference Microphone Mux Module Installation Instructions Remote Microphone Assembly Installation Instructions Product Reference Basic Panel Modules and Accessories Emergency Voice Alarm Communications Equipment Remote Annunciator Panels Sheet 4003 9803 Remote Microphone Reference on double gang box 2 51 mm depth by others switch TALK READY TO TALK LED the microphone is active talking may begin controls of remote to electrical with 4 mounting supplied 4 2013 4100 1274 Specifications Microphone Multiplex Module Module size Mounting Location Remote Microphone Input Sources Audio Input Module Details Voltage Current 4 x 5 block module either in same cabinet or close nippled to the cabinet housing Audio Controller or Auxiliary Audio Input Module Audio Controller Models 4100 1311 or 4100 1211 Audio Controller Model 4100 1210 Audio Input Module Model 4100 1240 to remote microphone outputs 3 and 4 to two 4100 1240 Auxiliary Audio Input Modules can be connected a compatible Audio Controller Module VDC system power microphones active 171 mA microphone active 219 mA microphone active and keyed 258 mA keyed microphones Add 39 mA for each keyed microphone Wiring Information field wiring Supervised IAM 570 supplied by IDNet Signaling Line Circuit SLC between Multiplex Module Remote Microphone Input twisted shielded pair TSP wiring to Audio Controller or Auxiliary Input Module Microphone Wiring 18 AWG 0.82 mm2 TSP Microphone Distance 4000 ft maximum 1220 m Supervised IAM Details and Wiring Information field wiring one IDNet address and one IDNet unit load address is switch on board to the control panel IDNet communications source desired using 18 AWG twisted pair Remote Microphone Environmental Specifications Temperature Humidity Range VDC system power from 4100 1290 24 Point I O Module mA maximum in use AWG 0.82 mm2 twisted shielded pair TSP for microphone 5 wires for keyswitch PTT switch and LED control to 120 F 0 to 49 C to 93 RH non condensing 90 F 32 C 4 2013 SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2013 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 4 2013

Related Files