Simplex 4100ES LED Switch Modules and Controllers; (Includes Local Printer)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Control Panels Panel Mounted LED Switch and LED Modules Controllers and Panel Mounted Printer mounted annunciation modules for use with Fire Alarm Control Panels Remote and Network Display Units NDU Modules mount on front of panel bay providing access and high visibility Panel monitors switches for user input and controls indicators to annunciate function status Compact 64 LED 64 switch controller modules mount back of LED switch modules Modules Raised momentary switches provide tactile feedback Alternate action operation provides on off functions High intensity LEDs provide clear status annunciation Slide in labels provide custom on site labeling label is ordered separately LED 8 Switch Modules One status LED per switch Available as all red LEDs or all yellow LEDs LED 8 Switch Modules Two status LEDs per switch Available with two LEDs per switch as red yellow red green or green yellow LED 16 Switch Modules One status LED per switch in 2 51 mm module Available as all red LEDs or 8 red and 8 yellow Two configurations are available one with pluggable refer to illustrations on page 2 and product details on page 4 LED 24 Switch Modules Double slot module with one red status LED per Hand Off Auto Switch Modules Eight controls in a double slot module each control three switches for status selection and one LED switch position Switch selection is On Hand Off and Auto with three HOA Module LED Options On Hand green LED Off red LED and Auto LED On Hand green LED Off red LED and Auto LED to comply with International Building IBC requirements On Hand green LED Off yellow LED and Auto LED for applications requiring no red LEDs Available with or without switch buttons labels Off Auto Modules with 8 or 16 pluggable LEDs 8 LED Module has red LEDs 16 LED module has red with 8 yellow Red yellow green or blue LEDs are available in of eight 8 to change color on site per requirement ordered separately B C K L T U E F N O W X 0 H I Q R Z WARNINGS Alarm 2 Alarm Silenced Power Alarm 2 or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions 2 Bay Fire Alarm Control Panel Sample of Available LED Switch Modules Continued Point I O Module for external connections Each point is selectable as either a switch input or maintained or lamp relay driver output Multiple switch monitoring modes are available mounted printer see pages 6 and 7 for details Records system events and provides 20 visible lines to UL Std 864 Fire Detection and Control UOJZ and Control Service UUKL UL Std 2017 Process Management Equipment UL Std 1076 Proprietary Alarm Units Burglar APOU UL Std 1730 Smoke Detector Monitor UULH ULC Std S527 99 Options 4100ES 4100U fire alarm panels a variety of switch input and LED status indicators complement the information and controls available at the interface These modules provide a convenient efficiently packaged onto the front panel space of cabinet bay Additionally the panel mounted printer can record system status without requiring a located printer Refer to additional listing details on page 4 This product has been approved by the State Fire Marshal CSFM pursuant to Section 13144.1 of the California and Safety Code See CSFM Listing 7165 0026 251 for allowable values and or concerning material presented in this document It is subject to revision and possible cancellation Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products 8 2018 24 Point I O Module is selectable for input switch and supervision type Outputs are selectable for on or pulsing to drive remotely connected relays lamps or LEDs Continued Interface Switches are alternate action ON OFF on programming selection using a tactile feel rubber button High efficiency LEDs provide clear annunciation readily visible through the glass door Functions Switch functions LED status and printer output is selected when the panel CPU is customized for site specific Slide in labels are locally printed to the exact function of the LEDs and switches LED Switch Module Detail Reference area H W mm 51 mm Modules insert Modules label labels area each column of and LEDs area Switches 16 LEDs R Y Y Y R G G Y Switches 16 LEDs R Y LEDs Switches 8 LEDs R Y Switches 16 LEDs R Y R Color Legend Red Yellow Green Red on top Yellow on bottom Red on left Yellow on right LEDs R LEDs LEDs R Y LEDs 8 2018 HOA and 24 24 LED Switch Module Detail Reference 8 2018 LED Switch Module Product Selection panel mounted switches are momentary pushbutton Modules General Purpose LED switch controller and label kit is ordered separately per Switch LED Color s Label Area Quantity Switch Quantity UL ULC and CSFM listed only on top Yellow on bottom on top and bottom on top Green on bottom on top Yellow on bottom Red on left 8 Yellow on right pluggable LEDs shipped on top Yellow on bottom module and per switch module and per switch per column of 8 pairs see on page 2 module and per pair module and per switch Only Modules and LED Kits LED switch controller and label kit is ordered separately Eight 8 LED Module with Red LEDs custom label are

Related Files