1 2 AN ALARM SUPERVISORY OR TROUBLE CONDITION OPERATING INSTRUCTIONS SAFETY AND THE SAFETY OF THOSE AROUND YOU ALWAYS COMES FIRST taken during a fire depend upon local practices Be sure you know what to do Using Individual Acknowledge LED FLASHES AND TONE ALERT PULSES LED FLASHES AND TONE ALERT ON STEADY Unlock and open the panel door The alphanumeric display shows the of abnormal conditions This example describes managing a condition A Supervisory condition is handled similarly Unlock and open the panel door The appearance of the alphanumeric depends on whether the Display 1st Alarm Option is enabled If Display 1st Alarm Option is enabled The display alternates two screens similar to Screen 1 and Screen 2 which is a description of the 1st alarm below 1 ACK to review FLOOR EAST WING ROOM 31 STATION If Display 1st Alarm Option is not enabled Only a screen similar to 1 appears indicating the total number of alarm conditions on the system Press the ALARM ACK key under the flashing red LED Read the display Continue to press the ALARM ACK key until all are acknowledged When this occurs the tone alert turns off the ALARM led changes from flashing to ON steady the Signals Press the ALARM SILENCE key and read the display The display reads SILENCE IN PROGRESS and the SILENCED LED turns on steady The Disable switch on the 4100 front panel is not to be used an alarm condition to silence the notification appliances the System When the alarm condition has been cleared restore or replace all devices smoke detectors motion sensors etc in accordance the instructions provided with each device Reset the system as follows FIRE ALARM Condition Press the SYSTEM RESET key PRIORITY 2 ALARM Condition Reset these conditions using either System Reset key or a dedicated CONTROL key located on left of panel a delay the red ALARM LED flashes and the tone alert sounds a pulsing tone the ALARM ACK key until all alarm conditions have been a delay the display reads IS NORMAL 0 ACK to review Press the TBL ACK key under the flashing yellow LED Read and instructions on the alphanumeric display The display shows the and type of problem as shown in the example below The tone momentarily silences and then resounds FLOOR EAST WING ROOM 31 MONITOR ZONE CKT TROUBLE Press the TBL ACK key under the flashing yellow LED again to the abnormal status The alphanumeric display shows the area type of problem the tone alert silences and the SYSTEM LED turns on steady Read the alphanumeric display and investigate the problem to determine its cause If a Trouble condition exists restore or replace the defective equipment wire device etc in accordance with the equipment When the abnormal condition causing the trouble clears the LED flashes and the tone alert sounds steady Press the TROUBLE ACK key under the flashing yellow LED The display shows the system status Press the TROUBLE ACK key again After a delay the system the following IS NORMAL 29 NOV 00 your system switch configuration does not match this sheet Simplex for specific operations Simplex is listed in the Pages case of trouble notify Press the ALARM ACK key under the flashing red LED Continue to AND MOUNT THESE INSTRUCTIONS ADJACENT TO THE PANEL OPERATOR MANUAL FOR DETAILED OPERATION 2001 Simplex Time Recorder Co Westminster MA 01441 Rev A 1 2 AN ALARM SUPERVISORY OR TROUBLE CONDITION OPERATING INSTRUCTIONS SAFETY AND THE SAFETY OF THOSE AROUND YOU ALWAYS COMES FIRST taken during a fire depend upon local practices Be sure you know what to do Using Global Acknowledge LED FLASHES AND TONE ALERT PULSES LED FLASHES AND TONE ALERT ON STEADY Unlock and open the panel door The appearance of the alphanumeric depends on whether the Display 1st Alarm Option is enabled If Display 1st Alarm Option is enabled The display alternates two screens similar to Screen 1 and Screen 2 which is a description of the 1st alarm below 1 ACK to review FLOOR EAST WING ROOM 31 STATION If Display 1st Alarm Option is not enabled Only a screen similar to 1 appears indicating the total number of alarm conditions on the system Press the ALARM ACK key under the flashing red LED Read the display The tone alert turns off and the ALARM led from flashing to ON steady the Signals Press the ALARM SILENCE key and read the display The display reads SILENCE IN PROGRESS and the SILENCED LED turns on steady the System When the alarm condition has been cleared restore or replace all devices smoke detectors motion sensors etc in accordance the instructions provided with each device Reset the system as follows FIRE ALARM Condition Press the SYSTEM RESET key PRIORITY 2 ALARM Condition Reset these conditions using either System Reset key or a dedicated CONTROL key located on left of panel Refer to a delay the red ALARM LED flashes and the tone alert sounds a pulsing tone the ALARM ACK key until all alarm conditions have been a delay the display reads IS NORMAL Unlock and open the panel door The alphanumeric display shows the of abnormal conditions This example describes managing a condition A Supervisory condition is handled similarly 0 ACK to review Press the TBL ACK key under the flashing yellow LED Read and instructions on the alphanumeric display The display shows the and type of problem as shown in the example below The tone momentarily silences and then resounds FLOOR EAST WING ROOM 31 MONITOR ZONE CKT TROUBLE Press the TBL ACK key under the flashing yellow LED again to the abnormal status The alphanumeric display shows the area type of problem the tone alert silences and the SYSTEM LED turns ON steady Read the alphanumeric display and investigate the problem to determine its cause If a Trouble condition exists restore or replace the defective equipment wire device etc in accordance with the equipment Trouble condition automatically clears when the abnormal condition been corrected IS NORMAL 29 NOV 00 your system switch configuration does not match this sheet Simplex for specific operations Simplex is listed in the Pages case of trouble notify The Disable switch on the 4100 front panel is not to be used an alarm condition to silence the notification appliances a short delay the system returns to normal and displays the Press the ALARM ACK key under the flashing red LED Continue to AND MOUNT THESE INSTRUCTIONS ADJACENT TO THE PANEL OPERATOR MANUAL FOR DETAILED OPERATION 2001 Simplex Time Recorder Co Westminster MA 01441 Rev A

Related Files