Simplex 4100ES Panel Application 4100ES Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control (B)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Control Panels Automatic Extinguishing Deluge and Preaction System Releasing Control control using the Simplex 4100ES 4100U Fire Alarm Control Panel to provide Coverage for multiple areas of Automatic Extinguishing and or Deluge and Preaction Sprinkler System including audible escalation of events Control of compatible Listed Approved 24 VDC control actuators one per circuit or two VDC actuators in series per circuit Releasing appliance circuits RACs by connecting appliance circuits NACs to Suppression Peripherals for actuator supervision and control Escalation of Events Temporal or 20 bpm March Time pattern for first 120 bpm March Time pattern to indicate releasing timer alarm On steady to indicate releasing timer expired and is activated NOTE Requires NACs dedicated to conventional horn not SmartSync operation with strobes on separate NACs Suppression Release Peripheral with Dual Command Control Dual command control requires that both IDNet commands and an activated NAC are to initiate the desired release NAC provides wiring supervision to the actuator monitoring of coil continuity and short circuit to the coil supervision module Release Peripheral control features An on board DC DC regulator compensates for drops to the peripheral and ensures proper circuit voltage over a wide operating range Provides a single RAC for control of actuators for up 2 A using a 3 A NAC input 1 A using a 2 A NAC system components 4100ES Series control panel with Releasing Appliqu Dedicated NAC output from 4100ES or compatible Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch connected via an addressable interface listed to Standard 864 This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listings and 7300 0026 313 SRP for allowable values and or conditions material presented in this document It is subject to re examination revision possible cancellation Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster Series Releasing Control Typical Block Diagram combined with Suppression Release Peripherals 4100ES series fire alarm control panel provides supervision and control for use in automatic and deluge or preaction releasing systems area initiating and notification devices are using either conventional or addressable per standard 4100ES capabilities The necessary system logic is implemented within the 4100ES panel as required for the local application Release Control operation described in this document is also available with 4100U Panels with software revision 11.05 or higher Refer to data sheet S4100 0031 model 4100ES control panel details including IDNet communications information sourceAgent dischargepathActuator Control CircuitActuatorMaintenance Disconnect Switch with indicator lamp Coil supervisory moduleCOIL SUPERVISION MODULE 2 AMP 2081 9046INSTALLATION INSTRUCTIONS 574 437 REVMAINTAIN 1 4 SEPARATIONBETWEEN POWER LIMITED RED BLK AND NONPOWERLIMITED YEL BLK WIRINGRED NAC NAC BLKDATE CODE 519 958YELBLKSSIMPLEX TIME RECORDER CO GARDNER MA USAFIRERELEASINGDEVICEDedicated NAC circuitIDNet communicationsTypical addressable initiating devicesMANUALRELEASERelease appliance circuit4100ES Control Panel with Suppression Release Appliqu Release Peripheral IDNET IN IDNET IN PUSH AND HOLDFIRE SUPPRESSIONSYSTEM ABORTNORMALDISC DISABLEFIRE SUPPRESSIONDISCONNECT DISABLE01Power for indicator lamp if required SUPPRESSION RELEASE PANELCAUTION This Control Unit has been arranged for releasing service Disable all releasing device circuits prior to servicing firealarmresources com Extinguishing Release Systems System Requirements Continued systems automatically activate electrically actuators for the release of a fire extinguishing such as dry chemical water spray foam CO2 or agent in response to fire detection device inputs as by programming of the host fire alarm control Extinguishing Release System Panels required to have a minimum of 24 hours of standby Initiating devices must be Listed Approved for the and may be wired either Class A or B actuators must be electrically compatible with the panel circuits and power supplies and are wired B to provide coil supervision or Preaction Sprinkler Systems systems automatically activate water control in response to fire detection device inputs Sprinkler Systems employ open sprinkler and provide water flow when the fire detection activates a common automatic water control They are used to deliver water simultaneously all of the system sprinkler heads This type of is applicable where the immediate application of quantities of water over large areas is the proper fire Sprinkler Systems are similar to deluge except that normally closed sprinkler heads are and supervisory air pressure is maintained in the Operation requires both an activated sprinkler head an activated fire alarm initiating device with specific determined at the host fire alarm control System Requirements Releasing actuators are controlled from a Release Peripheral 4090 9005 or Connections are 2 wire Class B releasing with only one 24 VDC actuator per circuit applicable two 12 VDC actuators in series or 12 VDC actuator with manufacturer supplied may be used Coil Supervision Module 2081 9046 must be wired before the actuator and located in the wiring junction box Refer to diagram on 5 The connected RAC provides continuity of the actuator coil and wiring and short circuit supervision to the coil module Cross zoning or other alarm initiation logic per requirements is to be implemented by at the fire alarm control panel UL Listed Automatic Extinguishing Releasing requires that battery standby must be a of 24 hours with 5 minutes of alarm and that actuators are used refer to list on page 6 FM Approved Automatic Extinguishing Release secondary standby to be a minimum of hours with 5 minutes of alarm Actuators must be compatible FM Approved Deluge and Preaction Sprinkler requires that initiating device circuits be A and wired to Listed Approved devices power capacity must be a minimum of 90 with 10 minutes of alarm and that compatible Water Control Valves must be used Refer actuator list on page 7 Maintenance Switches one per RAC are required NFPA 72 the National Fire Alarm Code 2002 Chapter 6 to allow the system to be tested or without actuating the fire suppression Their use may not be allowed in some always confirm local requirements used Simplex Maintenance Switches are to ensure that operation initiates a condition Abort Switches are available when abort operation is When used connect to an addressable IAM model 4090 9001 or similar adapter module The Simplex abort switch the IAM mount in a single gang box 2 1 2 depth Addressable Manual Releasing Stations are used to activation of the releasing actuators with the time delay implemented by the fire alarm panel Notification Requirements Each hazard area requires general audible and visible fire notification and additional dedicated NACs for releasing status notification Suppression is compatible with conventional panel NAC modules as well as for use with the IDNet NAC Extender Additional Suppression Release Peripheral Refer to Installation Instructions 579 385 Releasing Systems Reference additional information refer to Factory Mutual Corporation FMRC Approval Guide Approval standard Systems and Preaction note that proper operation of releasing control requires that the system design installation and be performed correctly and in accordance all applicable local and national codes and manufacturer instructions No liability

Related Files