Simplex 4100ES Products 4100ES Basic Panel Modules and Accessories (A) (B) (E) (F) (G)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Controller top bay 32 Bit Master Controller with color coded operator including raised switches for high confidence Dual configuration program CPU convenient service port and capacity for up to 2500 addressable points CPU assembly includes 2 GB dedicated compact flash for on site system programming and storage System power supply SPS and charger 9 A total with NACs IDNet addressable device interface auxiliary output and alarm relay Available with InfoAlarm Command Center expanded user interface see data sheet S4100 0045 Upgrade kits are available for existing control panels addressable interfaces include addressable device interface with 250 points that TrueAlarm analog sensing and operate with shielded or unshielded twisted pair wiring Remote annunciator module support via RUI remote interface communications port modules include Building Network Interface Module BNIC for Ethernet options see data sheet S4100 0061 Additional IDNet and MAPNET II addressable device and IDNet MAPNET II quad isolator modules output module with built in quad isolator and operation for better retrofit to existing wiring data sheet S4100 0046 Fire Alarm Network Interfaces DACTs city and up to five 5 RS 232 ports for printers terminals communicator compatibility Alarm relays auxiliary relays additional power IDC modules NAC expansion modules Service modems VESDA Air Aspiration Systems ASHRAE BACnet Interface TCP IP Bridges LED switch modules and panel mount printers Emergency communications systems ECS equipment channel digital audio or 2 channel analog audio Battery brackets for seismic area protection see page 2 with Simplex remotely located IDNet NAC Extenders up to ten per IDNet and upgrade kits are UL Listed to UL Std 864 Fire Detection and Control UOJZ and Control Service UUKL UL Std 2017 Process Management Equipment QVAX UL Std 1076 Proprietary Alarm Units Burglar APOU UL Std 1730 Smoke Detector Monitor UULH ULC Std S527 99 Fire Control Panels Addressable Fire Detection and Control Panel Modules and Accessories B C K L T U E F G N O W X 0 H I UX Q R DNet Z Alarm Priority 2 Alarm WARNINGS Silenced Power Alarm 2 or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions B C K L T U ET E F G N O W X 0 H I UX Q R DNet Z Alarm Priority 2 Alarm WARNINGS Power Silenced Alarm 2 or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions Cabinets are Available with Two or Three Bays Feature Summary provides dual configuration programs Two programs allow for optimal system protection and efficiency with one active program and reserve Downtime is reduced because the system stays running download based programmer features Convenient front panel accessed Ethernet port for quick easy download of site specific programming Modifications can be uploaded as well as downloaded greater service flexibility AND firmware enhancements are made via software to the on board flash memory Introduction 4100ES Series Fire Detection and Control Panels extensive installation operator and service features point and module capacities suitable for a wide range of applications An on board Ethernet port provides fast system communications to expedite installation and activity Dedicated compact flash memory archiving secure on site system information storage of job configuration files to meet NFPA 72 National Alarm and Signaling Code requirements design A wide variety of functional modules available to meet specific system requirements allow panels to be configured for either or Networked fire control operation InfoAlarm Center options provide convenient expanded content detailed on data sheet S4100 0045 See pages 5 and 6 for product that is UL or ULC listed and additional listing information product has been listed by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material in this document Accepted for use City of New York Department of Buildings Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products 4 2013 Module Bay Description Master Controller Bay top includes a standard system power supply the master controller and operator interface equipment Expansion Bays include a Power Distribution PDI for new 4 x 5 flat design option and also accommodate 4100 style modules Battery Compartment bottom accepts two up to 50 Ah to be mounted within the cabinet interfering with module space following illustration identifies bay locations using a bay cabinet for reference 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 Power Pwr Bay 1 2 3 4 5 6 7 8 Wiring Wiring Bay 1 PDI controller with slot motherboard power supply Module E Module F Wiring Module E Module F Wiring Power G H Power G H bays with module sizes 1 2 3 4 5 6 7 8 Wiring Wiring Bay 2 PDI Compartment Module Bay Reference Mechanical Description Boxes can be close nippled each box provides stud markers for drywall thickness and knockouts for quicker mounting Smooth box surfaces are provided for locally cutting entrance holes exactly where required Cabinet assembly design has been seismic tested and is to IBC and CBC standards as well as to 7 05 category D requires 33 Ah or 50 Ah with battery brackets as detailed on data sheet Mechanical Description Continued The latching dress panel retainer assembly easily off for internal ac

Related Files