Simplex 4100ES Products 4100ES Remote Annunciator Panels (B) (E)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Annunciator Panels provide fire alarm panel status information at locations from the fire alarm control panel functions include Remote status LED indicators and dedicated switch controls located on LED switch modules Remote status LED indicator modules with 8 red or 8 red 8 yellow LEDs that are pluggable to allow selection yellow green or red LEDs are separately Remote microphone and operator interface for access the emergency voice alarm communications system Remote master telephone for communicating to the telephone system Also available with InfoAlarm Command Center content user interface refer to page 5 and to sheet S4100 0045 for additional information optional modules include Remote Command Center module for LCD status and keyswitch controlled functions 24 Point I O module RS 232 ports for remote printer or terminal Power supplies with battery charger for annunciator Panel mounted printer for system status recording requirements RUI or RUI remote unit interface supervised from the host fire alarm control provide Style 4 or Style 7 SLC signaling line connections Microphone and telephone circuits require their own wiring to UL Std 864 Fire Detection and Control UOJZ and Control Service UUKL UL Std 2017 Process Management Equipment UL Std 1076 Proprietary Alarm Units Burglar UL Std 1730 Smoke Detector Monitor UULH ULC Std S527 99 See page 4 for additional listing details This product has been approved by the California Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Code See CSFM Listing 7165 0026 0251 for allowable values and or conditions material presented in this document Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products Control Panels Remote Annunciator Panels COMMAND CENTER 2 SYSTEM Operating Instructions or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Up Dn B C K L T U E F N O W X H I Q R Z 2 Alarm 2 Operating Instructions to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence or Warning Condition indicator flashing Tone On to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Remote Annunciator in a Three Bay Cabinet with Operator Modules Remote Command Center left with an InfoAlarm Command Center right Annunciator Panels are dedicated purpose that support fire alarm system status Typical use is when the host fire alarm panel is located away from the area where those to a fire situation need status information and Control Controls are suitable for or other fire brigade responders to access information and for system control When with a remote microphone and emergency communications system control an user can take command of the system and play selected pre recorded messages or select tones or initiate live broadcast information either into the system or to selected areas Master Firefighter Phone When equipped a remote master phone the authorized user can to remote phone call in requests and allow callers be connected to each other Although intended for use assisting fire responders these system are also helpful system setup and test 5 2013 Module Bay Description Remote Annunciators include a bay assembly a power interface module PDI a Transponder Interface and an interconnect harness Communications with host fire alarm control panel are via a Remote Unit RUI or RUI connection that allows for up to ft 762 m distance RUI can communicate with up to a of 31 remote devices per master controller on one or RUI channels and can be either Style 4 or Style 7 Wiring can be either shielded or twisted or untwisted single pair wiring Remote Annunciator This model is for that may require a full complement of the Annunciator functions refer to the product lists on pages 3 and 4 Power is from a cabinet Remote Power Supply RPS Basic Remote Annunciator For remote applications that require less features in the select this model which accepts power from a fire alarm control cabinet This model does NOT a cabinet mounted power supply expansion phone Class A phone modules RS 232 modules panel printers or 24 I O modules Expansion Bays each include a PDI and a variety of optional modules for specific annunciator Battery Compartment bottom accepts two up to 50 Ah Battery mounting does not interfere available module space Not applicable to the model Remote Annunciator Audio Module Reference Packaging Availability Modules are power limited except as noted such as modules Enclosure are available for one two or three bay sizes for cabinet rack mounting Boxes doors with tempered glass inserts and dress are available in beige or red ordered separately Refer to document S4100 0037 for enclosure details Remote Command Center optional Remote Command Center occupies the top of a Remote Annunciator It provides an LCD status with keyswitch activated control switches and a tone alert sounder Features are essentially identical the Remote LCD Annunciator model 4603 9101 document S4603 0001 COMMAND CENTER 2 Operating Instructions or Warning Condition indicator flashing Tone On to Acknowledge View Events ACK located under flashing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Remote Command Center 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Master Module 4100 1271 Switches with 8 LEDs 2 shown typical labels Microphone 4100 1244 Switches with 8 Red 4100 1280 Channel Audio 4100 1252 5 2013 Product Selection

Related Files