Simplex 4120 Network 2500 NDU Operating Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4120-network-2500-ndu-operating-instructions-8071293564.pdf |
---|---|
Type | |
Size | 5.84 MB |
Downloads |
Text Preview
Bimplex Network Network Display Unit NDU 1993 Simplex Time Recorder Co other specifications Manuals Online were current as of publication are subject change without notice 002 574 307 1 93 Manuals Online FSB 432R Service Bulletin 3,1993 4020 4100 4120 UT Modified Operator Interface Panel Replaces FSB 432 May 11 1993 Revised sections of the FSB are not shaded because FSB was rewritten modified Operator Panel Panels now have hardware and software made on the panel for the PRIORITY 2 LED which will be activated shortly The figure below ALARM SILENCED LED In addition supports TO OPEN DOOR NORMAL 20 MAY 93 OPERATING OR TROUBLE CONDITION SYSTEM INDICATOR FLASHING TONE ON ACKNOWLEDGE PRESS ACK LOCATED UNDER FLASHING REPEAT ORERATION UNTIL ALL REPORTS ARE SILENCE ALARM SIGNAL PRESS SILENCE RESTORE SYSTEM TO NORMAL PRESS RESET PRESS SILENCE TONE DEVICE to Silence Alarm Signals ALARM SILENCE key silences lights the ALARM SILENCED LED Evacuation Tone Message silence alarm evacuation press the Operator Panel ALARM SILEN key Panel Hardware and Software table below the hardware and software the modified panel Controller 565 l 48 565 209 Note 3 Notes 2 and 4 6.02 Note 1 565 l 73 Replaces 635 775 636 394 Replaces 635 775 553 612 5.03 6.02 553 612 5.03 Board Software The PRIORITY 2 ALARM LED is for future use and is not functional with System Software Version 6.02 The 565 331 Display Board Revision Bi Header Plug P7 on the 565 333 Master Controller have Pins 2 and 3 jumpered provide 12 Volts to the LCD System Software Version 6.02 downwards with all earlier of the Master Controller The 565331 Display Board can only be used with the 565 333 Master Controller Board Manuals Online Manuals Online OF CONTENTS 1 SYSTEM OVERVIEW Networking Network Display Unit 4120 8801 NDU with Status Command Center 4120 8821 Operating Description In Procedure Out Procedure Abnormal Conditions 2 ALARM CONDITIONS Acknowledge Panel Operation During Alarm Conditions to Silence to Reset the System Alarm Signals Acknowledge Panel Operation During Alarm Conditions Alarm Signals to Silence to Reset the System Alarm Condition Keys Acknowledge Key Silence Key Silence Software Considerations Reset Key the Alarm Point does not Reset to Disable a Point 3 TROUBLE CONDITIONS Acknowledge Panel Operation During Trouble Conditions Acknowledge Panel Operation During Trouble Conditions Trouble Condition Keys Acknowledge Key Reset Key the Trouble Does Not Reset to Disable a Point with a Trouble Condition TrueAlarmTM Sensors Dirty Indication Indication Dirty Indication Abnormal protected U S Patent No 5,565,468 Manuals Online 4 SUPERVISORY SERVICE CONDITIONS