Simplex 4190-6050, 4190-6054, 4190-6055 Fire Alarm Ethernet Switches; for local area network connection of TrueSite Workstation Servers to Remote Clients (A)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
ULC CSFM Listed Approved a dedicated Fire Alarm local area LAN for connection of a TrueSite server to remote clients Fire Alarm Ethernet Switches provide up to eight wired connections with individual earth fault Wired Ethernet cable distance of up to 328 ft 100 m Fire Alarm Ethernet Switches can be interconnected to connection capacity and or distance using either wired ports or fiber optic ports Fiber optic cable switch connections provides a distance up to 1.24 miles 2 km for multimode fiber and up to miles 15 km for single mode Fire Alarm Ethernet Switches are UL listed to 864 and ULC listed to Standard S527 Switches are available without earth fault supervision for applications not requiring fire alarm listings For additional TrueSite Workstation server and client refer to data sheet S4190 0016 with three connection options Eight Ethernet wired ports with RJ 45 terminations Four wired ports and two single mode fiber optic ports connectors connectors Four wired ports and two multimode fiber optic ports faults are reported three ways An on board IDNet Supervised IAM is available for to a compatible Simplex fire alarm control An on board trouble relay provides contact transfer On board LEDs identify fault location per port Fire Alarm Ethernet Switches combine an switch module with an earth detection circuit wired Ethernet connections housed in a dedicated Using Fire Alarm Ethernet Switches allows of a TrueSite workstation server and TrueSite workstation clients into a dedicated Alarm LAN When networked the TrueSite clients can monitor and if authorized fire alarm system activity If additional or increased distances are required Fire Ethernet Switches can be connected to additional Details The Fire Alarm Ethernet Switch uses an switching hub to bridge between connected data It also has the ability to segment the Ethernet in separate collision domains for network Fire Alarm Systems Fire Alarm Network Annunciators Alarm Ethernet Switches additional Remote Fire Alarm Switches if required Located Fire Ethernet Switch ALARM ETHERNET SWITCH Fire Command with Remote Client and status from local Alarm Control Panel Fire LAN Alarm Switch ALARM ETHERNET SWITCH Client Alarm Panel Workstation LAN Alarm Network Connections up 7 loop capacity access client Fire Alarm Center client Alarm Ethernet Switch Connection Reference Operation Data packets are inspected to the source and destination address of each then forwarded accordingly Simultaneous data are allowed on different data links resulting in throughput Operation is either half duplex or Communications Support Wired Ethernet protocols include 10Base T or allowing network Ethernet connection of 10 Mbps or 100 Mbps Models with fiber optic allow Fire Alarm Ethernet Switches to be using the advantages of fiber optics Fiber optics ports operate at 100Base FX Refer to product selection details on page 2 for listing specifics This product has been by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 7300 0026 336 for allowable and or conditions concerning material presented in this document It is subject to revision and possible cancellation Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products 3 2012 Earth fault status is indicated by the on board LEDs see list on page 4 Continued Earth Fault Detection When an earth fault is detected the Earth Detection Module it triggers a general for external monitoring Monitoring is performed either communicating with the on board IDNet IAM or monitoring the trouble relay contacts Product Selection Order Reference to be selected per order type Workstation Standard Operation Workstation Redundant Operation Workstation Fire Proprietary Supervising Station Workstation Remote Client Aftermarket Hardware Additions Ethernet Switch equipment and accessories are ordered as options for use with TrueSite Workstation upper level product model numbers per the System Order Reference section below For additional TrueSite Workstation information to data sheet S4190 0016 Alarm Ethernet Switches agency listed for fire alarm Eight wired Ethernet connections wired Ethernet connections and two fiber optic connections wired Ethernet connections and two fiber optic connections Switches not agency listed for fire alarm Alarm Ethernet Switch VDC red cabinet with Detection on wired 864 ULC S527 Each TrueSite Server and Client requires 4190 6010 Transient Suppressor see power is provided by a listed fire power supply Eight wired Ethernet connections wired Ethernet connections and two fiber optic connections wired Ethernet connections and two fiber optic connections Switch only W 10 36 VDC VA 8 24 VAC use Adapter per below 864 Recognized component does include Earth detection module or 5 11 16 x 7 3 8 x 1 3 4 mm x 187 mm x 44.5 mm Switch Power Adapters select one for each 4901 6051 4190 6056 or 4190 6057 Power Adapters are NOT for use Fire Alarm Ethernet Switches 4190 6050 4190 6054 or 4190 6055 they require connection to a fire alarm power supply Mount Power Adapter 6 ft 1.8 m cord 120 VAC 60 Hz 20 W 24 VAC 650 mA 240 VAC 50 Hz 78 mA 24 VAC 650 mA Size W x 2 15 16 H x 1 7 8 D mm x 74 mm x 48 mm W x 3 3 16 H x 1 15 16 D mm x 80 mm x 49 mm Suppressor for LAN WAN Connection Required for agency listing recommended for each TrueSite Workstation Server and Remote Client computer mounts on rear of PC frame for desktop or rackmount computers 3 2012 Interconnection Reference additional information refer to Installation Instructions 579 903 additional Remote Fire Alarm Switches if required Fire Command Center Remote Client Fire Alarm LAN for connection Fire Alarm Ethernet Switches Ethernet cable up to 328 ft 100 m Multimode fiber up to 1.24 mi 2 km Single mode fiber to 9.3 mi 15 km Located Fire Alarm Switch ALARM ETHERNET SWITCH Fire Alarm Panel Alarm Control Alarm Switch to local fire alarm panel to power and monitor trouble using communications with on board or by monitoring relay contacts between Fire Ethernet Switches and Workstation Server Client are wired Ethernet up to 328 ft 100 m ALARM ETHERNET SWITCH Client Alarm Panel Alarm Network Connections up 7 loop capacity Server Ethernet connections requires a Transient Suppressor assembly as located and connected at of computer Workstation Server LAN Fire Alarm Center client access client System Notes Available ports can be connected to other Switches to extend distance or extend Client capacity Fire Alarm Ethernet Switch 4190 6050 can support up to 7 clients and one server per Switch or up to 7 clients at a remote Switch location Fire Alarm Ethernet Switches with fi