Simplex 4190 Series IDNet or MAPNET II 4-20 mA ZAM (AMZ) (B)

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4190-series-idnet-or-mapnet-ii-4-20-ma-zam-amz-b-8472561903.pdf
Type PDF
Size 671.77 KB
Downloads

Text Preview

Multi Application Peripherals 4100U IDNet and MAPNET II Communicating Devices mA Analog Monitor Zone Adapter Module AMZ ULC Listed compatible 4 20 mA output sensors linear analog sensor data to Simplex fire panel models 4100U 4100 and 4120 4100U panels interface with the AMZ using either or MAPNET II communications 4100 4120 panels interface with the AMZ using II communications panel software 8 or higher Refer to special note below for additional important detection panel monitoring and annunciation Up to three threshold levels each with custom action Display and archive actual sensor analog levels Allows sensor calibration date recording Requires a single address two IDNet unit loads Up to 100 custom AMZ point types are available per or per connected Network module features Automatic and manual AMZ self test On board manual test switch provides WALKTEST test feature Resettable sensor power output Supervised sensor trouble input Local LED alarm annunciator output Mounts in 4 102 mm square electrical box or to 4100 or 4120 panel cabinet Monitor ZAMs AMZs provide an accurate interface for connecting analog sensors to 4100U 4100 4120 addressable fire detection The panel monitors the sensor and annunciates a selected threshold level or trouble condition is Typical applications include air quality for control ventilation air and liquid temperature and air velocity see listings reference on page 2 Compatible sensors are supplied by non SimplexGrinnell manufacturers distributors SIMPLEXGRINNELL DISCLAIMS ALL WARRANTIES NOR IS IT RESPONSIBLE FOR SERVICE TESTING AND OR INSPECTION OF THE SENSORS SIMPLEXGRINNELL ANY IMPLIED WARRANTIES OF AND FITNESS FOR A PARTICULAR REGARDING THE COMPATIBLE SENSORS sensor mA loop sensor output Surface mount AMZ LED VDC power Area contacts control of local functions IDNet 35 2 MONITOR STAGE 1 ALARM Control 4100U fire detection showing typical message System Interface Example Application Considerations The purpose of the AMZ is to communicate the of a compatible 4 20 mA sensor to the fire detection panel for proper fire alarm response including annunciation and event All responses required to be initiated by the for actions to be taken in the vicinity of sensor are to be performed by outputs from sensor not from the fire alarm control panel SimplexGrinnell does not assume responsibility for application selection inspection warranty or testing of the analog sensor AMZs and the connected panel are to be located of the monitored area and installed in with applicable local code requirements The AMZ accommodates 2 wire 3 wire or 4 wire to a compatible sensor Refer to listings compatibility chart on page 2 CSFM approval and MEA NYC approval not applicable for this product This product was not FM approved as of revision date listings may be applicable contact SimplexGrinnell for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Products IDNet addressable communications format is protected by U S Patent No 4,796,025 WALKTEST system test is protected under U S Patent No 4,725,818 Depicted sensor location is for illustration only Refer to specific sensor requirements proper location 12 2004 Detection Panel Features Data Access Real time analog sensor values be accessed using the front panel interface Data is in the specific units being measured Sensor Programming AMZ point types can designated as Fire Priority 2 Supervisory Trouble Supervisory or Utility each with custom label default the AMZ provides an abnormal if the monitored sensor produces an output below mA or above 20.0 mA Programmable Threshold Levels Each can have up to three separate threshold levels each a custom action message AMZ Point Types Up to 100 custom AMZ types can be programmed into a single fire alarm panel For Network applications the Network custom AMZ point type limit is also 100 maximum point types would be required for the same sensor but with different threshold values or for different with unique characteristics Date Recording Each sensor date can be manually entered for secured keeping Exporting Sensor activity pertaining to the three alarm threshold levels can be exported for via a Simplex Network using an Information System IMS Sensor Operation sensors provide a linear output current between 4.0 mA and 20.0 mA that represents the analog measurement as predetermined by the sensor The AMZ monitors the 4 20 mA loop and digitally communicates the sensor to the panel With this information the can determine whether a status annunciation is and can display the sensor analog level directly the appropriate units of measurement 4 to 20 mA loop is an established analog format is highly reliable and inherently supervised for loop For additional monitoring sensors with contacts can be directly connected to the AMZ trouble input circuit AMZ Product Selection Chart Mounting Models Mount Models AMZ package with mount box see diagram page 4 Coded Wire Leads AWG Compatibility mount AMZ select as required Series fire detection panels Network fire detection panels Blocks AWG maximum LED indicator gang stainless steel plate AWG Leads wire equivalents 18 AWG 0.82 mm2 12 AWG 3.31 mm2 Panel Mounting Notes of document revision date Panel mounting is available for Simplex model series 4100 and 4120 only Not available for mounting internal to 4100U series models AMZ mounting plate requires 4 of panel width with two AMZ mountable on one plate vertical mount AMZ Product Listings Compatibility Chart Model Listing Listing for use with Safety Appliances Co MSA model RT Refrigerant Gas Monitor for use with compatible 4 20 mA sensors listing status shown is as of document revision date Additional listings may be applicable contact SimplexGrinnell for the latest status and approvals under Simplex Time Recorder Co are the property of Tyco Safety Products Westminster 12 2004 AMZ Specifications and Current Specifications Voltage Output VDC 24 VDC nominal input voltage Current 3 or 4 wire devices mA maximum AMZ Current mA Loop Current mA minimum operation below 4.0 mA is a trouble condition mA maximum operation above 20.0 mA is a trouble condition Circuit Output Current mA for monitoring of dry trouble contacts voltage supplied by the AMZ LED Annunciator mA Specifications Trouble Input contact 29 VDC maximum Sensor Loop and Power AWG twisted pair or per sensor requirements IDNet IDNet address per AMZ Requires two IDNet unit loads II One MAPNET II address per AMZ IDNet MAPNET II Up to 100 custom AMZ point types total per Network to 100 custom AMZ point types per panel distance AMZ to sensor ft 1 km Range indoor locations 32 F to 120 F 0 C to 49 C Range to 90 RH AMZ Current Requirements Operation Loop 20 mA maximum Power 400 mA maximum mA mA mA Total

Related Files