Simplex 4190 series TrueAlarm Fire Alarm Systems; Fire Alarm Network Annunciators; TrueSite Incident Commander (A) (B)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Approved Incident Commander provides 4100ES for the Simplex TrueSite Workstation All in one touchscreen computer monitor mounts in 4100ES cabinet and is powered from the fire alarm power supply including battery backup Seismic hardware 4100ES mounting with battery provides seismic area protection see page 4 High resolution 1280 x 1024 19 483 mm monitor Includes Windows 7 Professional 32 bit operating Hinged mounting bracket allows convenient service Available for desktop use operating at 120 VAC with included power supply module Incident Commander function summary Simplex fire alarm network connected graphical control Connects to the Simplex fire alarm Network as a node access to remote panel activity status and for a Notification System event or a fire alarm event can control of remote panel activity over the fire alarm Available TCP IP LAN WAN connections up to 20 clients can be connected to the server for multiple users with dedicated and listed Fire Alarm LAN listed remote clients can have control access Supports standard fire service annunciation icons to firefighter and first responders with critical fire information Custom alarm and system messages can intuitively emergency responders important information locations contact information etc can be presented Color graphical annunciation and control capacity for to 62,500 points or point lists Floatable and dockable windows allows windows to be fixed docked or floatable Extensive historical logging up to 500,000 events with notations Optional interface to Digital Alarm Communicator DACR integrates multiple systems onto a Incident Commander Multiple password controlled operator levels Available optional connections for printers or other systems Dual monitor support allows the Alarm List Window to on one monitor and the Graphics Window on the other screens details Pan and zoom features allow precise navigation Configurable coverage zones allow user defined zones a graphics screen to highlight to indicate the area activity without zooming into the point of interest Auto jump allows the screen view to jump to a graphic alarm list menu Fire Alarm Systems Fire Alarm Network Annunciators Incident Commander Incident Commander Mounts in Bay 2 of a Control Panel shown with Master Controller TrueSite Incident Commander Incident Commander system features Test Mode allows unobtrusive testing of selective without nuisance interruptions Node Name allows a description of the specific building area associated with a point in views and reports Vector information to supervised remote clients by point event category panel or custom list Email generation is available to send updates to or to distribution lists with selectable content Sound files WAV can be used to create custom audible annunciation using Agency listed desktop PC 4190 7014 and integral PC speakers Fahrenheit or Celsius temperatures can be displayed next page Refer to pages 5 and 6 for specific product listing details This product has been by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 7300 0026 323 for allowable values conditions concerning material presented in this document Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection 5 2013 system features Continued DACR Account Filter allows Historical Log Reports to Filtered by DACR Account for Quick Access and of Information associated with an Individual Operator Notes allows an operator to log operator notes with individual events for historical records retrieval Web Browser Command Link enables the ability to call up an external web page or link web cam with a single command button on a graphic screen listings UL 864 ULC S527 as Control Unit Annunciator UL 864 for Fire Proprietary Supervising Station UL 864 UUKL as Firefighter Smoke Control Station UL 1076 ULC C1076 for Proprietary Security UL 1610 as Central Station Burglar Alarm Control Unit ULC S559 for Proprietary Fire Signal Receiving Fire Alarm Network capabilities Multiple TrueSite Incident Commanders and TrueSite can be nodes on the same fire alarm to provide redundant operations for improved Standard fire alarm network connection for wired or optic media Graphical network diagnostic tools Set host service functions allow access to remote node data including individual TrueAlarm sensors Provides event printing with compatible printer view print of status and service report information and graphic screens see page 6 for printing details Please refer to TrueSite Workstation data sheet for additional operation detail TrueSite Incident Commander offers TrueSite operation in an all in one package providing touchscreen computer monitor hard drive and required connections all in single assembly This installation within a 4100ES fire alarm control or remote annunciator with power supplied from the alarm power supply and secondary batteries This is also available for desktop applications Annunciation TrueSite Incident Commanders annunciation status display and control for Fire Alarm Networks using a personal computer graphical interface with a high resolution color Response buttons with realistic icons provide switches specific to the operation being performed Clients For remote viewing of TrueSite Incident Server information remote clients are available connected using TCP IP LAN WAN Ethernet As discussed on pages 7 and 8 Remote can be annunciation only or capable of system when configured with agency listed hardware Compatible For systems requiring information remote control panels via DACTs Digital Alarm Transmitters Incident Commanders can be to communicate directly with a compatible DACR Refer to data sheet S4190 0016 for more DACR details TrueSite Incident Commander Operation When fire alarm network status changes the screen displays the type and location of the or other activity and the appropriate header appear In the historical log screen on page 3 1 Fire Priority 2 Supervisory and Trouble are shown with an active Trouble indicated Screens Figure 1 on page 3 is representative a historical view screen Figure 2 on page 4 is of a system graphic screen with icons the devices of interest Screen choices can be per system preference however when using optional second monitor both screen types can be for operator convenience of Operation With touchscreen monitors the touches the screen area in alarm or uses the control to access a more detailed view of the zone or device With the proper password access operator has the ability to acknowledge alarm and conditions activate signal silence and perform reset directly from the Incident Commander Activity Timeout allows an monitor to revert to the login screen when the time period expires User Preferences appear when the user in Options include Font Size default or large Size small or large Interface Theme MS 2003 or System Floating Window Options select to show Menu bar or show Tool bar Log and List Details Figure 1 on page 3 historical log details The display format is similar the display for active list items such as the alarm list information can be sorted on screen by each shown number time date point name etc information can be reviewed on the screen printed at local or remote system printer or can be written to an file for compatibility with spreadsheet and programs Response Custom alarm and trouble can be added and field edited to p

Related Files