Simplex 4604-9201 Graphical LCD Annunciator™ Installation and Configuration Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4604-9201-graphical-lcd-annunciator-installation-and-configuration-instructions-6519732840.pdf |
---|---|
Type | |
Size | 1.99 MB |
Downloads |
Text Preview
II Simplex Graphical LCD Annunciator Configuration Upon unpacking your Simplex product inspect the contents of the for shipping damage and notify Simplex damage is apparent immediately file a claim with the HAZARD Disconnect electrical power when making any internal or repairs Servicing should be performed by qualified Simplex FREQUENCY ENERGY This equipment generates uses and can radiate frequency energy and if not installed and used in accordance with the instruction may cause interference to radio communications has been tested and found comply with the EMC Requirements of Standard GB47 17 93 of the People of China as well as the European Economic Community EEC standards EMC EN50082 1 1992 and EMI EN55022 Class A and is designed to reasonable protection against such electro magnetic interference when in a commercial environment Operation of this equipment in a residential is likely to cause interference in which case the user at his own expense will be to take whatever measures may be required to correct the interference 1 supports symbol based 4604 9201 Graphical LCD Annunciator such as Chinese Japanese Korean and Thai and is part of the 100 4 120 Fire Alarm Control Panel FACP product line The annunciator with the FACP via RUI Remote Unit Interface communications that require symbol based language annunciation are configured with the 4100 Programming Unit in English i e the job is built and the the FACP in English Tools are provided to the translation of the English custom labels and the in circuit burning of Flash chips within the Graphical LCD Annunciator Graphical LCD Annunciator configuration and the internal mount configuration The remote configuration compatible with the 4 100 4 120 product lines This configuration describes how to install an remote mount Graphical LCD Annunciator compatible with all 4100,4120 and 4020 product lines The offered in two different configurations is downloaded 1 4604 9201 Remote Mount Annunciator 1997 Simplex Time Recorder Co specifcations information shown were current as of publication and are subjed charge without notice A 4604 920 1 Graphical LCD has the following requirements Precautions 4604 920 1 Graphical LCD Annunciator can be semi flush mounted or maximum of 3 1 annunciators can be connected to a 4 100 FACP When wiring an annunciator at least 18 AWG twisted wire is required twisted shielded pair wire is used the shield must be grounded in the FACP following wiring precautions should be observed when wiring the Graphical Annunciator Wire lengths in excess of those listed in Tables 1 through 5 are not permitted wiring must be copper conductor shielding is used you must observe the following Metallic continuity of the shield must be maintained throughout entire of the cable entire length of the cable must have a resistance greater than 1 Megohm earth ground shield must connect to a SHIELD terminal at each annunciator and be grounded only at the main panel shielded wire is not used wire must be run in metallic conduit or equivalent wiring must be free of water must not be run through elevator shafts runs in plenums must be in conduit is permitted provided that such connections are soldered rosin core solder crimped in metal or encapsulated with an epoxy resin When solder or crimped metal sleeves are used the junction insulated a high grade electrical tape as sound as the original insulating jacket shield continuity is maintained throughout annunciator box must be connected to Earth Ground or building steel system wiring can share the same conduit cable length on next page Precautions Graphical LCD Annunciator cannot be used with wiring that goes outside the above or below ground unless overvoltage suppression is provided at ends Communication and power wiring must meet the following Simplex Model 208 l 9044 Overvoltage Protectors 2OOmA or less restrictions on wire routing Maximum wire length is 2500 feet Simplex Model 2081 9027 Loop Circuit Protectors Underground Wiring select the appropriate isolated loop circuit The circuit wiring must be run in a separate parallel wiring separated from any commercial power distribution wiring max or 2081 9028 max Overhead Wiring select the appropriate isolated loop circuit The wiring is limited to one contiguous property and the wire length must not exceed 2500 feet The circuit wiring must be on separate poles separated from any poles supporting commerical distribution wiring The circuit wiring must be run in parallel direct relation to the commercial power distribution The is a minimum distance whichever is greater of 100 feet or maximun span between any two adjacent poles of either the system or the commericial power distribution circuit maximum wire lengths when using protectors see Tables 2,4 5 on next page Wiring Graphical Communications terminal blocks accommodate 12 to 18 AWG wire When used with audio riser wiring telephone wiring and or 4 120 Network must be twisted shielded pair the communication configurations are acceptable where the total distance of all series and or runs do not exceed the maximum permitted distance See Tables 3 5 Power terminal blocks accommodate 12 to 18 AWG wire 2 power must be provided by the system power supply All circuits are limited Tables 1 on next page Wire Lengths wire lengths for the Graphical LCD Annunciator are shown in 1 through 5 wiring is shown in Tables 1 and 2 1 With 2081 9044 Overvoltage 2 Without Transient Suppression Loop Circuit Protectors with 2081 9028 AWG 18AWG 25OOft 1 234Ofi 1 665fi 58Ofi 52Ofi 465fi 425fi 390ft on next page Total Current A 12 AWG 25OOfi 25OOft 2500ft 25OOft 1875ft Wire Lengths wiring is shown in Tables 3 through 5 3 With 2081 9044 Overvoltage 4 Without Transient Supression with 2081 9028 Protecltors mm AWG mm AWG mm 5 With 2081 9027 Circuit Protectors mm AWG mm AWG mm AWG mm maximum quantity of four 2081 9044 Overvoltage Protectors and four Loop Circuit Protectors are permitted on any single on next pa Requirements Graphical LCD Annunciator has the following power requirements VDC Power Supply VDC nominal 18 VDC to 32 VDC