Simplex 4605 23-Point I-O Card Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4605-23-point-i-o-card-installation-instructions-5976082413.pdf
Type PDF
Size 628.68 KB
Downloads

Text Preview

Cautions and Warnings 24 Point I O Card Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area is likely to cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4605 24 Point I O card with a 4010 Alarm Control Panel FACP A maximum of six of these option cards is per system Refer to the 4010 Fire Alarm Installing Operating and Instructions 574 052 for configuration information Refer to the Field Wiring Diagram for additional wiring information this Publication publication discusses the following topics Page 24 Point I O Card Installation 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B 24 Point I O Card 4605 24 Point I O Card is a card that communicates to the 4010 The 24 Point I O Card for the 4010 is capable of using any combination of inputs or outputs to control LEDs lamps relays and contact closure inputs outputs can be on continuous or flashed at a slow or fast rate The inputs may unsupervised supervised for opens supervised for open and shorts or Off Auto switches depending upon how the switch is wired for complete wiring instructions refer to the 842 063 Field Wiring The inputs and outputs must be provided by a listed signaling device 1 shows the location of the connectors and switches on the 4605 I O E M O T E W R COMM B 5 B 2 B 3 B 1 1 W 1 D D R E S S W 2 2 2 R 1 R 2 R 3 R 4 R 5 D R 6 R 7 R 8 R 9 R 1 0 D R 1 1 D R 1 2 D R 1 3 D R 1 4 D R 1 5 D R 1 6 D R 1 7 D R 1 8 D R 1 9 D R 2 0 R 2 1 R 2 2 R 2 3 D R 2 4 1 4605 24 Point I O Card Switches and Connectors B 4 Settings Address Setting SW1 cards in the 4010 system have specific addresses The range of card setting for the 24 Point I O card is Cards 9 through 14 Use Table 1 to SW1 to the appropriate address 1 SW1 Address Switch Settings Address thru SW1 8 the CFIG Add NEW Hardware function described in the 4010 Alarm Installation Operation Instructions 574 052 to add the card to the Rate Setting SW2 Communications on option cards must be set at the same baud rate as the FACP The 24 Point I O card baud rates are set from SW2 Use the in Table 2 to set SW2 to the appropriate baud rate The default should be 9600 2 SW2 Baud Rate Settings Rate I O Wiring Figure 2 and the notes below to wire the 24 Point I O card E M O T E W R 2 C O M M All wiring to be 18AWG minimum or to local B 5 B 2 B 3 B 1 1 W 1 D D R E S S Note 10 W 2 2 2 Power C Power C Comm Comm Notes 3 and 11 Note 7 Conductors must test free of all grounds Voltage input 18.9VDC min to 32VDC max Maximum current is 75mA per output Drawing depicts typical wiring All output may not be wired Supervision for the inputs are by passed in software Wiring is supervised and Power Limited For N2 Comms wired in a fashion the line distance is 4000 ft For N2 wired in a T Tapped configuration maximum distance to any N2 device is ft with maximum total wire distance to exceed 10,000 ft on the T tapped lines the 24 Point I O is the last device on the N2 Non T Tapped or the furthest device terminate across N2 and N2 a 733 974 100 1 2W resistor Total current 60mA base controller current current for each output used Wiring to I O terminals must not be run with B 4 wiring P2 10 P2 11 P2 12 P2 13 P2 14 P2 15 P2 16 P2 17 P2 18 P2 19 P2 20 P2 21 P2 22 P2 23 P2 24 R 1 R 2 R 3 R 4 R 5 D R 6 R 7 R 8 R 9 R 1 0 D R 1 1 D R 1 2 D R 1 3 D R 1 4 D R 1 5 D R 1 6 D R 1 7 D R 1 8 D R 1 9 D R 2 0 R 2 1 R 2 2 R 2 3 D R 2 4 Alternate Ribbon Cable for TB4 LAMP U T P U T LED U T P U T 2 24 Point I O Wiring Allowable power supplies 4010 9101 9102 9202 9813 and 9814 or any Power Limited supply that is UL for Fire Protective Signal Use Note 4 Installation Bracket the 4605 8402 mounting bracket supplied into the electrical back box by others When mounting the bracket be careful not to pinch any behind the bracket The bracket is designed to hold up to six 24 Point cards the 24 Point I O a position for the 24 Point I O card on the mounting bracket and install card using the stand offs and screws provided 24 Point I O Card Bracket Pay careful attention to the routing for Power and Non Power Limited wiring You must a 1 4 inch separation between these two of wiring Neatly dress all harnesses and dress all harnesses and wiring and then apply power B

Related Files