Simplex 4605 Series; 4010-9860, -9860CAF, & -9861 24 Point I O Annunciators and 24 LED annunciator doors for the 4010 (C)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4605-series-4010-9860-9860caf-9861-24-point-i-o-annunciators-and-24-led-annunciator-doors-for-the-4010-c-3742685190.pdf |
---|---|
Type | |
Size | 682.08 KB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Approved NYC Acceptance 24 Point I O Annunciator Modules for with the 4010 Fire Alarm Control Panel Peripherals input output module for use with model 4010 Simplex addressable fire alarm panel 4605 Series Models provides 24 input output I O per module with each point selectable as either an or an output input switch types are supported Unsupervised switch connection Supervised for open to switch circuit Supervised for open or short to switch circuit Monitored three position H O A hand off auto switches may be Normally open N O or normally closed N C Momentary or maintained Rated 24 V at 75 mA each for operation of relays lamps or current limited LEDs Selectable for continuous on or slow or fast flash communicate with the 4010 control using N2 serial communications Up to six total annunciators are supported Compatible annunciators include the 24 I O module the LCD annunciator and the 24 LED door annunciator Communications are provided with extended diagnostics quick setup and easy maintenance Series 24 Point I O Package availability Modular package with cabinet with or without retainer door for up to six modules Plate mounting for up to six modules for use with by others Module only for expansion or for use with mounting and enclosure by others available as a door mounted 24 LED 24 Point I O module dedicated for 24 LED individually selectable as red or yellow Standard on ULC models and available as door only for electronics only packages or for installation listed to Standard 864 Refer to page 2 for listing exceptions for the door mounted LED annunciator The 4605 24 Point I O module has been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products additional devices to six modules total SYSTEM IS NORMAL 12 02 15pm Mon 9 Feb 98 LCD Annunciator for reference mounted 24 Point I O Module 2 cid 31 7 72 5 H 7 72 8 5 1 cid 31 5 cid 31 8 67 7 72 8 5 1 cid 31 S 5 cid 31 33 7 8 5 1 cid 31 2 cid 31 7 72 5 7 cid 31 6 1 62 5 2 Graphic Annunciator Panel and wiring SYSTEM IS NORMAL Mon 8 Mar 99 TROUBLE ALARM ISC ON NEC T WER BEFORE VIC IN G Fire Alarm Control Panel Application for 24 Point I O Module with LCD Annunciator for reference only Description 4605 Series of I O modules provide a flexible remote for graphic annunciators HVAC monitoring and output bypass control utility door monitoring emergency call switches Each I O point can be as an input or output as determined by local Outputs and Inputs Outputs can be to be continuously on or pulsed at a slow or fast Inputs can be selected to be unsupervised supervised open circuit wiring supervised for open or short wiring or to monitor three position switches such those used for H O A hand off auto switch control 2 2006 Description options include a module only package or multiple modules mounted on a plate suitable installation in separately purchased cabinets modules to six mounted in a Simplex cabinet or as door 24 LED annunciators for use on the 4010 Flexibility Up to six N2 modules may be connected to the 4010 external annunciator communications bus These may be either the 4606 9101 LCD annunciator the 24 Point I O module Product Selection 4605 Series Graphic I O Modules and Accessories Type select one see Note below and refer to page 3 for reference drawing mounted modules six maximum for use with Simplex cabinet ordered separately below mounted modules six maximum for cabinet by others only Type order quantity as required Selection select if cabinet mounted reference 4605 8401 2 Unit Cabinet mounts up to six modules with glass door retainer 2 Unit Cabinet mounts up to six modules without door and back box only finish option Backbox select if backbox is to be pre shipped back box only no door or retainer select as required trim kit H x 21 3 8 W mm x 543 mm x 6 1 2 146 mm x 165 mm H x 25 3 4 W x 4 1 4 D mm x 654 mm x 108 mm H x 25 3 4 W x 4 1 4 D mm x 654 mm x 108 mm Point I O Module includes mounting hardware x 6 1 2 146 mm x 165 mm If the 24 Point I O equipment is used for a custom graphic annunciator panel one output must be configured and wired to a power on indicator on the front panel to meet UL requirements Product Selection Reference 24 LED Annunciator Doors Fire Alarm Control Panels with 24 LED Annunciator Door see page 4 for reference drawing Listed 4010 Fire Alarm Control Panel with Beige 24 LED Annunciator door beige 120 VAC input power supply battery charger IDNet interface 4 NACs 2 auxiliary and external N2 communications interface refer to data sheet S4010 0001 for control details LED Annunciator Doors for Aftermarket Add On to Existing Panels ordered separately Door with 24 LED Annunciator and dress panel suffix selects French Door with 24 LED Annunciator and dress panel These products are ULC listed only as of document revision date H x 18 W x 1 23 32 mm x 457 mm x 44 mm As of document revision date 4010 9860 and 4010 9861 are UL ULC and CSFM listed and FM approved only see CSFM listing 4010 9860CAF is ULC listed and FM approved only 2 2006 Specifications Voltage and Switch Voltage to 32 VDC system supplied Connections external annunciator communications line from 4010 Fire Alarm Control Panel blocks for wire size 18 to 14 AWG 0.82 mm2 to 20.8 mm2 Operating Current mA 24 VDC Rating mA 32 VDC maximum per output 1.8 A total maximum 7.3 mA when closed no current draw when open state open Switch activated 3.7 mA N C 7.3 mA 7.3 mA N C 3.7 mA state for and short Switch activated 3.2 mA N C 5.6 mA 5.6 mA N C 3.2 mA Current 24 VDC