Simplex 4606 Series Color Touchscreen LCD Annunciators for 4007ES Fire Alarm Control Panels

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed NYC Fire Dept Approved Accessories LCD Annunciators 4606 Series Color Touchscreen LCD Annunciators 4007ES Fire Alarm Control Panels Color Touchscreen LCD annunciators for with Simplex model 4007ES fire alarm control 109 mm diagonal color touchscreen display Provides the display features of the 4007ES fire alarm panel at a remote location Convenient and intuitive user interface provides detailed status and individual point information LED status indicators include Alarm Priority 2 Trouble Alarm Silenced and Status of Power at the control panel Supports dual language selection including unicode languages Keyswitch is used to enable default access level user access levels are passcode protected and user access levels are configurable Tone alert sounder provides local audible indication Three programmable control switches with status and provisions for custom labeling features Available with platinum or red trim is transmitted over a single unshielded pair separate wiring is required for 24 VDC Mounts flush on RACO 944 5 gang electrical box separately Up to 6 Color Touchscreen LCD Annunciators per fire alarm control panel box options ordered separately see 2 for more details Surface mount boxes in red or platinum Semi flush mount boxes in red or platinum may be for legacy annunciator retrofit applications Annunciation and Control 4606 9200 Series Annunciators allows 4007ES fire alarm control to provide information and control switches at locations away from the control panel The touchscreen LCD with backlighting displays in clear and descriptive language English is other languages can be programmed Typical includes point status alarm trouble etc alarm smoke detector manual station etc number of alarms supervisory conditions troubles and location labels up to 40 characters long Data communications require a unshielded twisted pair that supports other on the same communications channel This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document NYC Fire Dept COA 6191A Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products LCD Annunciator with Platinum Trim LCD Annunciator with Red Trim Continued Alarm Priority 2 Supervisory Trouble and Silenced conditions are indicated by dedicated LEDs a tone alert audible indication Each condition will cause display to present a dedicated acknowledge push button that silences the tone alert but leaves the LED on until conditions in that category are restored to normal Background The 4007ES control panel supports custom background image that is also displayed on each of color touchscreen annunciators when status is normal types supported are JPG BMP GIF and PNG image type is JPG recommended image size 480 x 240 and the file size limit is 100 kb Access Touchscreen display access can be by a keyswitch with a key that is removable only the disabled position Access is configurable per Operations When the keyswitch is on system indications will be displayed as they occur with point detail as programmed at the control panel soft keys will be displayed to allow user actions Backlight When the display has not been and no new system status has occurred for seconds the backlight dims to 20 of normal brightness there is no activity in the system System is Normal the screen displays current time and date to verify operation If an event occurs or with the keyswitch and the screen is touched the backlight returns to intensity Test The display menu provides a lamp test feature when selected activates the 9 panel LEDs for 5 seconds LEDs will blink alternately 1 2017 Product Selection Platinum Color Touchscreen LCD Annunciator for flush mounting a 5 gang RACO 944 box or equal supplied separately mount metal box for above annunciators mount metal box adapter for above annunciators use mounting on existing 2 gang 4 gang 6 gang or 4 102 mm flush mounted boxes W x 5.21 H x 2 D mm x 132 mm x 51 mm 944 Box reference W x 4 H x 2 D mm x 114 mm x 64 mm W x 4 H x 2 D mm x 114 mm x 64 mm W x 4 H x 1 D mm x 114 mm x 44 mm Models with BA are available assembled in the USA by adding the suffix Products Suppression is required where annunciator communications and power wiring exits and enters a building Protector rated for up to 200 mA use for RUI communications Loop Circuit Protector ILCP rated for 5 A maximum use for 24 VDC wiring when above 200 mA Reference Sheet S2081 0016 Sheet S2081 0008 Operator Information 1 2017 Specifications Operating Specifications to 32 VDC system supplied Current Details Details 124 mA Backlight at full intensity and tone alert sounding Active 70 mA Backlight at full intensity occurs when activity is in process 45 mA Backlight dimmed to 20 of full intensity occurs after 1 minute of no system Temperature Range Humidity Range to 120 F 0 to 49 C to 93 RH non condensing at 100 F 38 C 4007ES Panels RUI Remote Unit Interface external annunciator communications line SLC signaling line Up to 6 Color Touchscreen LCD Annunciators Requirements Wiring Type Unshielded twisted pair UTP 18 AWG 0.82 mm2 for most applications see below Characteristics 0.58 580 nF maximum capacitance between conductors 35 maximum total line Wiring that leaves the building RUI wiring also requires 2081 9044 Overvoltage Data Applications Shielded Pair STP on each end Wiring run in 500 ft 152 m or more of conduit Wiring closely bundled with standard IDNet communications or TrueAlert addressable B wiring not required when run with IDNet communications Up to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device X wiring distance Up to 2500 ft 762 m for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power dedicated earth ground connection to the electrical box is required for proper ESD and protection wire in accordance with NFPA 70 National Electrical Code Article 250 Wiring Wiring Information for Flush Mounting separately Reference Instructions Data Sheets masonry box RACO 944 2 64 mm deep or equal 4007ES Hybrid 4007ES with IDNAC Notification Operator Screen Reference shown approximately full size refer to page 4 for additional screen reference 1 2017 Operator Screen Reference Menu Screen provides easy navigation to the function Buttons A B and C have programmable functions Alarm Screen identifies active alarms with custom displayed arrows allow navigation through the list Trouble Screen identifies active troubles with labels displayed arrows allow navigation through list Log Screen allows review of past troubles with stamp and point details shown Information Screen allows review of point details allow navigation through the information Access Login Screen controls access to panel

Related Files