Simplex 4610-9111, 2975-9228 LED Switch Annunciator for use with the 4006 and 4008 Fire Alarm Control Panels

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC Listed FM CSFM Approved LED Switch annunciator for the Simplex and 4008 fire alarm control panels with 16 LEDs with functions programmable at the host panel indicate specific system conditions and locations Supervisory Trouble etc Dedicated LEDs that indicate Alarm Silence Trouble Loss and Power on Local tone alert audible indicator access control switches provide Event Acknowledge Alarm Silence System Reset and Lamp Test LED options 10 Red LEDs to indicate Alarm conditions by area 6 Yellow LEDs to indicate Trouble conditions Custom label inserts describe LED functions requirements Twisted pair for communications 24 VDC system power via separate wiring options Red surface mount box model 2975 9228 ordered Flush mount uses standard 5 gang electrical boxes Listed to Standard 864 9th Edition LED Annunciation Simplex 4610 9111 Annunciators provide remote fire alarm status and control with 16 programmable LEDs to location specific information Keyswitch access allows pushbutton switches to activate Alarm Silence system Reset or local LED Test Label inserts allow custom LED to be identified This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation This was not approved by MEA NYC as of document revision date Additional listings be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Products Accessories LED Annunciators Annunciator Model 4610 9111 and Accessories i r e A l a r m A n n u n c i a t o r COM LED Switch Annunciator Continued LEDs and Remote Switch Control indicate Alarm Silenced Communications Loss panel Trouble and local Power on along with a tone alert audible indication Activating the push button switch silences the system but leaves the LEDs on until all conditions in category are restored to normal LED operation or pulsing is programmed at the control System Annunciators Annunciator for these panels can include up to four including the LED Switch Annunciator an LCD Annunciator and the optional host panel LED Annunciator Information Refer to LED Switch Installation Instructions 579 710 and to the panel instructions Selection Annunciator red trim surface mount box red 10 W x 4 1 2 H x D 254 mm x 114 mm x 64 mm matching resistor 100 cid 58 1 2 W part number see specifications on page 3 for location quantity protector required where annunciator and power wiring exits and enters a refer to data sheet S2081 0016 for details 12 2004 Annunciator Detail View Custom label areas labels insert pockets behind the overlay Alarm Silence and Lamp Test switches Red LEDs i r e A l a r m A n n u n c i a t o r COM yellow LEDs output Silenced Lost Communications and Yellow LEDs Power Green LED 12 2004 Specifications Specifications Current Current to 33 VDC system supplied mA mA maximum all LEDs and tone alert on Temperature Range to 120 F 0 to 49 C Humidity Range to 93 RH non condensing at 100 F 38 C Communications Supported Type Matching to four annunciator modules per panel pair or twisted shielded pair 18 AWG 0.82 mm2 to 4000 ft 1219 m 0.58 580 nF maximum capacitance 35 cid 58 maximum wiring wiring Up to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device wiring Connect one at panel and one at end of line wiring Connect one at panel and one at farthest device cid 58 1 2 W PID 4081 9011 number 733 974 for wiring external to 2081 9044 Overvoltage Protectors where wiring leaves and enters a building to data sheet S2081 0016 Wiring Connections VDC system power and Earth ground for electrical box ground per local code for in out wiring 18 to 12 AWG 0.82 mm2 to 3.31 mm2 Information see diagram on page 4 Dimensions Material W x 4 1 2 H 254 mm x 114 mm steel red for Flush Mounting by others 5 gang boxes with conduit entrance restrictions refer to installation on page 4 Matching Surface Mount Box ordered separately W x 4 1 2 H x 2 1 2 D 254 mm x 114 mm x 64 mm steel red 12 2004 Mounting Information Mounting Boxes Matching surface mount box shown ordered separately For flush mount use 5 gang boxes per below NOTE To avoid interference with the annunciator use only conduit knockouts that are 2 1 2 64 mm from front of box or as noted below For masonry box use RACO 699 or equal 3 1 2 89 mm deep For plasterboard walls use RACO 590 3 1 2 deep or RACO 600 or equal use side knockouts or cable clamps top or bottom plate and assembly screws are supplied mm mm mm Assembly plate Simplex and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries Wiremold is a trademark of The Company 2004 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 12 2004

Related Files