Simplex 4901-9838CA, 4901-9839CA, 4901-9851C, 4901-9852C 4901 Series Insuite Silenceable Devices – Multi-Application Peripherals and Accessories

File Preview
File Preview
Click below to download for free

Text Preview

Listed Peripherals and Accessories Series Insuite Silenceable Devices Switch and Silenceable Mini Horn Silenceable Devices Allows manual 10 minute Silence for local mini horn for switched 24 VDC or 25 70 VAC audio appliances After 10 minutes automatic resound occurs for code if the fire alarm panel has not been silenced Touching the two Silence contacts activates the Silence and an LED indicator activates to indicate local is in process Models 4901 9838CA and 4901 9839CA operate as a Switch for connected slave appliances Models 4901 9851C and 4901 9852C have a built in Units mount flush using a single gang electrical box Electrically polarized input with color coded 18 AWG leads for in out wiring Compatible with 4905 Series Insuite Device Modules refer to data sheet S4905 0009 additional information Series Insuite Silenceable Devices are specifically to meet applications that require compliance building codes which state that an audible signal located within a dwelling unit shall incorporate a that enables the device to be silenced for a period not more than 10 minutes Typical applications would hotel rooms dormitories and apartments silenceable devices mount flush to the wall in a gang electrical box and are available in red or In Out wiring and electrical polarization allows system wiring supervision when connected to a listed Fire Alarm notification appliance circuit models The 4901 9838CA and 4901 9839CA used to silence audible DC or speaker appliances that located in a suite They operate as part of either a VDC or 25 or 70 VRMS Audio NAC In 24 VDC and VRMS Audio applications these units can be used with without the 4905 Series Distribution Modules Switches require separate 24 VDC power from Fire Alarm Control Panel This power must be during the use of the fire alarm paging when the switch modules are used to silence or 70 VRMS speakers Silenceable Device Switch 4901 9839CA is shown with LED on Continued models Models 4901 9851C and have a built in piezoelectric mini horn that a high level signal to be generated in a small These units operate as part of a 24 VDC NAC can be used with or without the Simplex 4905 Series Modules appliances in the suite are silenced by touching two Silence contacts on the faceplate of the device which also causes the LED indicator to Within ten minutes after touching the contacts to the alarm the notification appliances will re sound the Fire Alarm panel has not been silenced Reference to Installation Instructions 579 1009 for additional Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 11 2011 Product Selection Table Description VAC VDC DC On 3m mA mA mA mA mA mA dBA dBA VDC VDC Product Dimensions and Electrical Box Requirements Box Requirements Box minimum depth 3 recommended 11 2011 11 2011 Application Diagrams Audio Application Distribution and Insuite Silence Modules B Supervision VAC Circuit Supervised Circuit Supervised non Insuite Fire Alarm Device Device Resistor 10K Ohms VDC VDC VDC VDC VAC VAC VAC VAC VAC VAC VAC VAC 1 2 V Audio Operation 3 4 V Audio Operation When the 4901 9838CA 4901 9839CA silence switch is used in conjunction with slave speakers this 24 VDC power source provided by the Fire Alarm Panel must be interrupted during use of the fire alarm microphone diagram provides an applications overview not all wiring is shown For detailed wiring connection information refer to Installation Instructions 579 Distribution Modules and 579 1009 Insuite Silenceable Devices Note The 4905 9996CA does not accept an input from a 70V Audio NAC Distribution and Insuite Silence Modules Application B Supervision VDC Circuit Supervised Circuit Supervised non Insuite Fire Alarm Device Device Resistor 10K Ohms VDC VDC Audible Audible Audible Audible 1 2 Operation 3 4 Operation diagram provides an applications overview not all wiring is shown For detailed wiring connection information refer to Installation Instructions 579 Distribution Modules and 579 1009 Insuite Silenceable Devices 11 2011 Application Diagrams Continued Silence Switch Modules Distribution Modules No Short Circuit Isolation Diagram B Circuit for Corridor NAC A Circuit for NAC to Suites Notification Appliance Resistor 10K Ohms next Suite with Switch return loop circuit VDC from Fire Control Panel VDC from Fire Control Panel 70VAC 70VAC 70VAC 70VAC When the 4901 9838CA 4901 9839CA silence switch is used in conjunction with slave speakers this 24 VDC supply must be interrupted during use the fire alarm microphone Silenceable Mini horn Device Distribution Modules No Short Circuit Isolation Diagram Alarm VDC B Circuit for Corridor NAC A Circuit for NAC to Suites Notification Appliance Resistor 10K Ohms next Suite with Switch return loop circuit VDC SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2011 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 11 2011

Related Files