Simplex 4901-9850 & 4901-9853 TrueAlert Addressable Horns (G)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4901-9850-4901-9853-truealert-addressable-horns-g-9105428673.pdf |
---|---|
Type | |
Size | 721.89 KB |
Downloads |
Text Preview
TrueAlert Addressable Notification Appliances ULC Listed FM CSFM MEA NYC Approved Audible Notification Appliances Electronic Horns 4901 9850 and 4901 9853 addressable low power electronic provides Supervision of each individual appliance wiring and Ability to connect using tapping for B Style 4 circuits to simplify wiring A Style 6 circuits require in out wiring Harmonically rich output sound suitable for either or steady operation Magnetic test diagnostics to assist checkout and of appliances and wiring Sound level that can be chosen at the controller to be as a output or a output dBA difference Rugged high impact flame retardant thermoplastic available in red or white covers are available to convert color listed to Standard 464 Indicator and magnetic test feature LED indicator can be selected to display each polling to indicate appliance supervision When the TrueAlert addressable controller is in mode the magnetic test pulses the LED to appliance address and is selectable to also sound the horn to confirm operation two wire addressable control of audible visible notification provides Horns sounded as Temporal or March Time pattern or controlled separately from visible on the same two wire circuit Addressable March Time rates are 60 or 120 beats per Visible appliances connected to the same circuit at a synchronized 1 Hz flash rate addressable notification appliance provides flexible easy and convenient or surface wall box mounting Rear of housing does not extend into box and easily to single gang double gang or 4 inch square box wiring terminals 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Addressable Horns are Available in Red with Lettering and White with Red Lettering addressable horns are individually audible notification appliances that receive supervision and control signals from a TrueAlert Signaling Line Circuit SLC channel When they produce an audible output that is a loud penetrating harmonically rich sound addressable operation allows horns to wired onto the same two wire SLC circuit as visible but with separately controlled operation applications are audible notification appliances as and visible notification activated In addition visible strobes on the same circuit are activated with flashes Addressable Advantage Fire alarm control panels typically both audible and visible notification upon receipt an alarm At the direction of an authorized operator or pre determined program audible notification may be silenced before the alarm condition is on until silenced while the visible notification are kept activated until the alarm condition is on until reset This operation has traditionally two different circuits four wire operation TrueAlert addressable notification is protected under U S Patent Nos 6,313,744 and 6,693,532 6 2005 Addressable Advantage Continued Addressable Diagnostics Features The TrueAlert Addressable Controller be selected to pulse each appliance LED when that receives a supervision poll When the TrueAlert Controller is selected for diagnostic mode TrueAlert addressable appliance magnetic test feature a response at the individual appliance being Appliance Testing In this test mode in to the magnetic test the appliance LED pulses to conveniently indicate the appliance Appliance Testing The LED diagnostic mode can be selected at the TrueAlert Addressable such that after the address is indicated the horn briefly sound to indicate proper operation Addressable Wiring Isolator 4905 9929 Isolator Module is available for use TrueAlert addressable circuits to isolate short circuited from functioning wiring Refer to data sheet for further information about the TrueAlert Isolator Module addressable operation provides separate and visible appliance control functions using a two wire circuit that also confirms connection to individual notification appliance electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections for Reducing Installation and Time Allowing separate controls to be carried the same two wire SLC can significantly reduce time and expense for both retrofit and new When Class B Style 4 wiring is used can be tapped allowing even more savings in wire junction boxes and overall installation The magnetic test feature described below can provide improved installation efficiency Addressable Control controllers include the following Series TrueAlert Power Supply refer to data S4100 0031 for additional information TrueAlert Addressable Controller an intelligent panel that connects between the host fire control panel and the TrueAlert addressable appliances refer to data sheet S4009 0003 additional information Addressable Electronic Horns Product Selection Adapters Addressable Horn with white lettering with red lettering H x 5 W x 1 1 2 D mm x 127 mm x 38 mm Surface Mount Adapter Skirt Surface Mount Adapter Skirt to cover 1 1 2 surface mounted H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm depth with horn 3 1 8 79 mm Plate red for mounting to Simplex 2975 9145 Box for retrofit may be mounted vertical or horizontal x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm Mounting Box requires 4905 9931 Adapter Plate x 5 1 8 x 2 3 4 D mm x 130 mm x 70 mm Covers and Guard horn cover with white lettering horn cover with red lettering color H x 5 W x 1 1 2 D mm x 127 mm x 38 mm Wire guard with mounting plate compatible with surface semi flush mounted boxes H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm UL listed by Space Age Electronics Inc 6 2005 Installation Reference is compatible with gang double gang and 102 mm square boxes 38 mm deep by others Holes gang 2 gang 4 square 4 setting indicator location CKT wiring test points are with cover removed terminals are from rear location cover required Adapter Plate Installation Reference Adapter Plate Box Horn Adapter Plate Optional Wire Guard here for reference only can be used on other mounting options 6 2005 Specifications