Simplex 4901-9856, 4901-9857 TrueAlert Notification Appliances;SmartSync™ 2-Wire Operation, Non-Addressable Multi-Tone Horns

File Preview
File Preview
Click below to download for free

Text Preview

Features Low current 24 VDC Simplex SmartSync operation electronic multi tone horns provide Per appliance tone selection of Horn Bell 500 Hz Horn Canadian Horn Slow Whoop Siren or Hi Lo selected using an on board DIP Switch Output level selectable as standard or high Rugged high impact flame retardant thermoplastic housings available in red with white lettering or white with red lettering Diode polarized input for connection to reverse polarity supervised SmartSync control Notification Appliance Circuits NACs SmartSync two wire control of audible and visible notification appliance provides Control of horn and bell tones as Temporal Pattern March Time pattern or on continuously controlled separately from visible appliances on the same circuit Slow Whoop Siren and Hi Lo tone selections sound their tones continuously synchronized to each other when receiving Temporal Pattern March Time or continuous SmartSync commands SmartSync March Time pattern produces a 60 BPM output for the Horn 500 Hz Horn and the Bell tone Canadian Horn produces a 20 BPM output from the SmartSync March Time pattern command Visible appliances on the same circuit operate at a synchronized 1 Hz flash rate Refer to page 2 for SmartSync control list and additional operation information TrueAlert notification appliance design provides flexible easy and convenient semi flush or surface wall mounting Easily mounts to single gang double gang or 4 inch square electrical box In out wiring terminals 18 AWG to 12 AWG Rear of housing does not extend into box Optional Accessories Mounting adapters to cover surface mounted electrical boxes and to adapt to Simplex 2975 9145 boxes UL listed wire guard UL ULC listed sound damper for locations requiring attenuation of 5 to 6 dBA stairwells small rooms highly reverberant areas etc Covers are available separately to change color or for replacement Listing reference UL listed to Standard 464 ULC listed to Standard S525 TrueAlert Multi Tone Horns are Available as White with Red Lettering or Red with White Lettering Description TrueAlert non addressable multi tone horns provide a flexible selection of output tones for fire alarm audible notification Tone selection and output level is set per appliance allowing notification needs to be tailored to specific area requirements Refer to tone output details on page 3 Local Tone Selection DIP Switch selection determines the local tone choice A separate DIP Switch position allows selection of a standard or a high output sound level selectable appropriate to the location See page 3 for sound output ratings Canadian two stage alarm applications The Canadian Horn setting allows the SmartSync March Time pattern input to be produced as 20 BPM 20 BPM is typically required for Canadian two stage alarm applications as the pre signal followed by the Temporal Pattern Two stage alarm operation requires a 4010 or 4100U as the control panel Flexible mounting Multi tone horns can be semi flush or surface mounted on a standard single gang double gang or 4 square 102 mm electrical box Optional accessories are available to increase mounting and application flexibility Refer to page 2 for guard listing This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7135 0026 334 for allowable values and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Safety Products Westminster SmartSync two wire horn strobe operation is protected under U S Patent No 6,281,789 TrueAlert Notification Appliances UL ULC CSFM Listed FM Approved SmartSync 2 Wire Operation Non Addressable Multi Tone Horns S4901 0014 1 4 2010 firealarmresources com SmartSync Two Wire Control SmartSync operation mode allows a two wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing The horn operates as while the strobe operation is SmartSync Control Sources SmartSync two wire control is available from 4006 4008 4100U and 4010 Fire Alarm Control Panels refer to individual product data sheets for more information 4009 IDNet NAC Extenders refer to data sheet S4009 0002 SmartSync Control Module SCM Model 4905 9938 refer to data sheet S4905 0003 2 S4901 0014 1 4 2010Model Cover FIRE Lettering Description Dimensions 4901 9856 Red White TrueAlert non addressable multi tone horn 5 1 8 H x 5 W x 1 1 2 D 130 mm x 127 mm x 38 mm 4901 9857 White Red Sound Damper and Adapters Model Description Dimensions 4905 9838 Optional Sound Damper package of 20 field installed adhesive backed horn output attenuator reduces output 5 to 6 dBA NOTE After Sound Damper installation measure sound level to ensure compliance with applicable code requirements 1 3 4 Diameter 44.5 mm with 0.31 8 mm sound opening 4905 9937 Surface mount red adapter skirt Use to cover 1 1 2 deep surface mounted boxes 5 3 8 H x 5 1 4 W x 1 5 8 D 136 mm x 133 mm x 41 mm Total depth with horn 3 1 8 79 mm 4905 9940 Surface mount white adapter skirt 4905 9931 Adapter Plate red for mounting to Simplex 2975 9145 box typically for retrofit may be mounted vertical or horizontal 8 5 16 x 5 3 4 x 0.060 thick 211 mm x 146 mm x 1.5 mm 2975 9145 Red mounting box requires Adapter Plate 4905 9931 7 7 8 x 5 1 8 x 2 3 4 D 200 mm x 130 mm x 70 mm Synchronization Control Module Model Description Dimensions 4905 9938 SmartSync Control Module Class A or Class B installs in 4 square box 4 x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 mm Covers and Guard Model Description Dimensions 4905 9988 Red horn cover with white lettering 5 1 8 H x 5 W x 1 1 2 D 130 mm x 127 mm x 38 mm 4905 9989 White horn cover with red lettering 4905 9961 Wire guard with mounting plate red compatible with semi flush or surface mounted boxes 6 1 16 H x 6 1 16 W x 3 1 8 D 154 mm x 154 mm x 79 mm UL listed by Space Age Electronics Inc Product Selection firealarmresources com 3 S4901 0014 1 4 2010Rated Voltage Range 16 VDC to 33 VDC Rated Current 35 mA Temperature Range 32 to 122 F 0 to 50 C Humidity Range 10 to 93 non condensing 100 F 38 C Connections Terminal blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for in out wiring Multi Tone Horn Sound Output Characteristics see notes as indicated Tone Description Sound Output Ratings per UL 464 Reverberant Chamber test 10 ft 3 m Sound Output Ratings per ULC S525 Anechoic Chamber test 3 m 10 ft Standard Output High Output Standard Output High Output Horn1 or Canadian Horn1 2400 to 3700 Hz sweep modulated at 120 Hz rate 77 dBA 86 dBA 92 dBA 102 dBA Bell1 1560 Hz modulated at 7 ms intervals 73 dBA 87 dBA 84 dBA 99 dBA 500 Hz Horn1 500 Hz tone 77 dBA 86 dBA 84 dBA 99 dBA Slow Whoop2 500 Hz to 1200 Hz sweep 73 dBA 83 dBA 90 dBA 103 dBA Siren2 600 Hz to 1200 Hz 1 sec on then repeat 67 dBA 79 dBA 87 dBA 100 dBA High Low2 Alternating tones of 1000 Hz and 800 Hz 250 ms duration 77 dBA 86 dBA 91 dBA 102 dBA Sound Dispersion per ULC S525 testing 3 dBA at 30 off axis 6 dBA at 50 off axis For Private Mode use only Always test installed sound level against local requirements Tones at this setting are not for use in ULC fire alarm applications Notes 1 These tones are controlled by SmartSync commands to produce Temporal Pattern March Time Pattern or Continuous Selecting Horn 500 Hz Horn or Bell mode will produce a 60 BPM March Time Pattern selecting Canadian Horn mode CA Horn will produce a 20 BPM March Time Pattern typically used for Canadian two stage alarm applications 2 Slow Whoop Siren and High Low tones run Continuous when receiving any of the SmartSync ON commands As with the horn and bell tones they are synchronized to the controlling SmartSync timing commands allowing synchronization across multiple NACs Multi Tone Horn2975 9145 Box4905 9931 Adapter Plate4905 9931 Adapter Plate4905 9961 Optional Wire Guard shown here for reference only can be used on other mounting options Multi Tone Horn Specifications 4905 9931 Adapter Plate Installation Information firealarmresources com Tyco is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo IDNet TrueAlert and SmartSync are trademarks of Tyco International Ltd and its affiliates and are used under license Tyco Safety Products Westminster Westminster MA 01441 0001 USA S4901 0014 1 4 2010 www tycosafetyproducts usa wm com 2010 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as

Related Files