Simplex 4903-4904 TrueAlert Non-Addressable Switchable AV and Free-Run Strobe Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4903-4904-truealert-non-addressable-switchable-av-and-free-run-strobe-installation-instructions-3429678501.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
4903 4904 TrueAlert Non Addressable A V and Free Run Strobe Instructions and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product inspect contents of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify Simplex HAZARD Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Therefore handle as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times use the 553 484 Static Control Kit FREQUENCY ENERGY This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instruction manual may cause interference to radio It has been tested and found to comply with the limits for a Class A computing device pursuant Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such when operated in a commercial environment Operation of this equipment in a residential area may interference in which case the user at his own expense will be required to take whatever measures may be to correct the interference Non Addressable A V and Strobe Operation TrueAlert 4903 Audible Visible A V and 4904 Strobe see Figure 1 are non wall mounted Notification Appliances that provide an audible and or A V or a Visible Only Strobe warning indication of an alarm condition activated from the control panel of a UL listed Simplex Fire Alarm System the Notification Appliance emits sound and or light it indicates the of an emergency situation that requires your immediate attention TrueAlert A V and Strobe are Notification Appliances that operate on a reverse Notification Appliance Circuit NAC When this NAC is in the reverse or supervision state these appliances do not operate and present a high to the circuit They operate their notification appliance actuators when respective NAC changes polarity entering the state Switchable A V 4 wire A V utilizes two circuits that operate independently The first circuit NAC1 controls the A V strobe circuit A V strobe is configured using a single position DIP switch The DIP switch set to configures the A V strobe circuit to Free Run the DIP switch set to configures the A V strobe circuit to synchronous operation Synchronous operation requires a Simplex sync module not supplied 4009 IDNet NAC Extender or 4010 Fire Alarm Control Panel FACP with a synchronous NAC circuit The factory default setting for SW1 is synchronous operation second circuit NAC2 controls the A V horn operation the A V horn follows the On Off state of the second NAC Free Run Strobe 2 wire Strobe activates a high intensity pulsed light output at a free run rate determined by circuitry within the unit The of the Strobe appliance flashes at a minimum rate of 1 Hz its flashing is asynchronous to any other signals are 3 models of each version of the 4903 A V and 4904 Strobe each has a different light output rating 15 candela 75 candela and candela TrueAlert A V and Strobe units are available in red and white color versions Table 1 through Table 3 describe A V and features and current ratings 1 TrueAlert Notification Appliances A V Strobe 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice and IDNet are trademarks of Simplex Time Recorder Company D Non Addressable 2 Wire Free Run Strobe and 4 Wire A V Terminal Connections to Figure 2 for terminal connections for the Free Run Strobe and 4 Wire A V and mode switch location and settings for the 4 wire A V Only ON 4 INPUT A V ONLY SLOT FOR WIRING AWG NOTES SW1 RECESSED IN HOUSING FREE RUN MODE SHOWN SYNCHRONOUS MODE 3 INPUT A V ONLY 2 INPUT A V OR INPUT STROBE 1 INPUT A V OR INPUT STROBE TERMINALS ACCEPT WIRES 12 18 AWG VDC POWER INPUT NOTE 4 2 TrueAlert Free Run Strobe and 4 Wire A V Terminal Connections Non Addressable Free Run Strobe Wiring Make sure that all power is disconnected before starting the installation Connect wiring to terminals as shown Do not loop wires under terminals Break wire runs to provide supervision of Do not bring conduit through the rear of the electrical box Strip lead insulation to 3 8 maximum At the enclosure box run contractor wiring through the cutout slot and connect the wires to the NAC and NAC terminals at the front the Strobe unit see Figure 2 Torque terminal block screws 12 15 in lbs to ensure proper continuity Refer to Figure 3 for terminal wiring connections When connecting more than one Strobe to a circuit ensure that correct polarity is maintained on each unit When connecting the last Strobe on a circuit connect an end of line resistor EOLR to the terminals 16 33 VDC NON CODED APPLIANCE OR PRECEEDING NOTES LAST APPLIANCE ON CONNECT EOLR NOTES STROBE STROBE STROBE Notification Appliances are rated per individual nameplate label Maintain correct polarity on terminal connections Do not loop wires under terminals Refer to the Field Wiring Diagrams supplied with the FACP for detailed NAC wiring information appliances were only tested to the operating voltage limits of 16VDC and 33VDC Do not operate these appliances these limits doing so may cause appliance to fail to operate and or cause permanent damage to this equipment 3 4904 TrueAlert Free Run Strobe Wiring Non Addressable 4 Wire A V Wiring Make sure that all power is disconnected before starting the installation Connect wiring to terminals as shown Do not loop wires under terminals Break wire runs to provide supervision of Do not bring conduit through the rear of the electrical box Strip lead insulation to 3 8 maximum At the enclosure box run contractor wiring through the cutout slot and connect the wires to the NAC1 and NAC2 terminals the front of the A V unit see Figure 2 Torque terminal block screws 12 15 in lbs to ensure proper continuity Refer Figure 4 for A V terminal wiring connections When connecting more than one A V to a circuit ensure that correct polarity is maintained on each unit When connecting the last A V on a circuit connect an end of line resistor EOLR to the terminals 16 33 VDC NON CODED APPLIANCE OR PRECEEDING 2 2 NOTES 2 2 2 2 LAST APPLIANCE ON CONNECT EOLR NOTES 16 33 VDC CODED APPLIANCE OR PRECEEDING 1 1 1 1 1 1 NOTES A V A V A V 4 Wire Terminal Connections 16 33 VDC NON CODED APPLIANCE OR PRECEEDING NOTES NOTE 6 A V A V AWG BLACK NAC WIRE AWG RED NAC WIRE LAST APPLIANCE ON CONNECT EOLR NOTES A V 2 Wire with Jumpers Terminal Connections Notification Appliances are rated per individual nameplate label Maintain correct polarity on terminal connections Do not loop wires under terminals All NAC wiring connections are supervised and power limited Refer to the Field Wiring Diagrams supplied with the FACP for detailed NAC wiring information appliances were only tested to the operating voltage limits of 16VDC and 33VDC Do not operate these appliances outside these limits doing so cause appliance to fail to operate and or cause permanent damage to this equipment Terminals accommodate two 2 12 18 AWG wires of wire gauges is not recommended