Simplex 4903 TrueAlert AV Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4903-truealert-av-installation-instructions-0782413956.pdf |
---|---|
Type | |
Size | 1.08 MB |
Downloads |
Text Preview
4903 TrueAlert A V Instructions and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product inspect contents of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify Simplex HAZARD Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Therefore handle as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times use the 553 484 Static Control Kit FREQUENCY ENERGY This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instruction manual may cause interference to radio It has been tested and found to comply with the limits for a Class A computing device pursuant Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such when operated in a commercial environment Operation of this equipment in a residential area may interference in which case the user at his own expense will be required to take whatever measures may be to correct the interference A V Operation 4903 TrueAlert Audible Visible A V unit see Table 1 is a wall mounted appliance that provides an audible and or visible indication of an alarm when activated from a TrueAlert compatible control panel of a UL listed Fire Alarm System When the notification appliance emits sound and or it indicates the possibility of an emergency situation that requires your attention TrueAlert A V unit is a notification appliance that operates only on a Signaling Line Circuit SLC The appliance is via communications with the TrueAlert Addressable Controller than via conventional appliance supervision A V unit responds to communication signals over the SLC from a panel Coded messages from the TrueAlert controller turn on A V strobe and horn The A V can only be operated through a 4009 9401 Addressable Controller using Simplex TrueAlert Comm Channel A V horn provides selectable high low volume sound pressure levels with audible output types of Steady Temporal and Time fast slow The compatible TrueAlert Addressable Controller or FACP is used to configure the features The TrueAlert A V will not operate on a conventional NAC A Vs are available rated at 15 candela 75 candela and 110 candela Each model is available with a red or white cover 1 lists the available A V models 1 TrueAlert A V 1 Wall Mount TrueAlert A V Models Description A V 15 CANDELA A V 75 CANDELA A V 110 CANDELA A V 15 CANDELA A V 75 CANDELA A V 110 CANDELA Model 4903 9450 4903 9451 4903 9452 4903 9453 4903 9454 4903 9455 A V Cover Color Red White 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a trademark of Simplex Time Recorder Company or following an eight digit product ID number denotes ULC listed product B A V Wiring Make sure that all electrical power is disconnected before starting the installation Connect wiring to terminals as shown Do not loop wires under terminals Break wire runs to provide of connections Strip lead insulation to 3 8 maximum the enclosure box run contractor wiring through the cutout slot and connect the wires to the CKT and CKT terminals at front of the A V unit Torque terminal block screws 12 15 in lbs to ensure proper continuity See Figure 2 Ensure that correct polarity is maintained for each A V unit SLC wiring must be twisted pair TWP SLOT FOR WIRING AWG TWP NOTES 2 INPUT 1 INPUT TERMINALS ACCEPT WIRES 12 18 AWG TWP NOTES TrueAlert COMPATIBLE CONTROLLER NOTES A Wiring See Notes NEXT APPLIANCE OR SLC NOTES TrueAlert COMPATIBLE CONTROLLER NOTES B Wiring See Notes Maximum 43 appliances per circuit Maximum 30 ohms wire resistance between appliances Refer to Field Wiring Diagrams of the driving compatible Fire Alarm Control Panel for further instructions Notification appliances are rated per individual nameplate label Maintain correct polarity on terminal connections Do not loop wires under terminals All TrueAlert SLC wiring connections are supervised and power limited appliances were only tested to the operating voltage limits of 17V to 31V Do not operate these appliances outside these limits doing so cause appliance to fail to operate as intended and or cause permanent damage to this equipment TrueAlert A V can only be operated through a compatible TrueAlert Addressable Controller is not allowed for Class A wiring 2 TrueAlert A V Wiring the TrueAlert A V Figure 3 for mounting the TrueAlert A V to the enclosure box When surface mounting the A V either the or 4905 9940 TrueAlert Surface Mount Skirt is recommended Refer to the 4905 TrueAlert Skirt Instructions 574 790 for this mounting application Tighten screws snugly do not overtighten Torque mounting screws 5 7 in lbs For semi flush mounting install the box either flush with the wall or with a maximum recess SCREW HOLES FOR MOUNTING NOT SUPPLIED NOTES 1 and 3 SCREW HOLES FOR 4 SQUARE MOUNTING SCREWS SUPPLIED NOTES 1 and 2 FROM 748 472 GROUP QTY 2 SCREWS CORNER A V COVER SCREW HOLES FOR MOUNTING NOT SUPPLIED NOTES 1 and 3 INDICATED BY DOTTED LINES SWITCH SW1 NOTE 4 and TABLE 2 SQUARE BOX SUPPLIED DEEP REQUIRED NOTES 1 and 2 NOTE 4 TrueAlert A V unit attaches directly to a standard single gang double gang or 4 inch square electrical box not supplied semi flush or mounted are four holes for 4 inch square electrical box mounting Secure the housing to the 4 inch square electrical box using two mounting screws The two mounting screws are placed cross corner depending on how the box has been mounted are two holes for single gang and double gang electrical box mounting Secure the housing to the single gang or double gang box using mounting screws 6 32 inch x 1 1 8 inch long not supplied The two mounting screws are placed cross corner opposite top and bottom for the double gang installation remove the cover press the snap release in one at a time with a flat tip screwdriver while pulling up the cover with the other hand Switch SW1 is accessible with the cover removed 3 TrueAlert A V Mounting the A V Address TrueAlert notification appliance has a unique address Each appliance address is set via an eight position DIP as shown in Table 2 see Figure 3 for the general DIP switch location DIP switch position 1 is the least bit LSB and position 8 is the most significant bit MSB DIP Switches 1 through 6 are used to set the possible 63 address codes DIP Switches 7 and 8 are not used and set to a small screwdriver or pen to set the switches and then record the address This information provides an aid in the system 2 TrueAlert A V Units DIP Switch Address Chart SWITCH SHOWN IS AT ADDRESS 7 ON OFF USED FOR USE SWITCHES 5 AND 6