Simplex 4903 TrueAlert SV Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4903-truealert-sv-installation-instructions-8460219375.pdf
Type PDF
Size 1.11 MB
Downloads

Text Preview

4903 TrueAlert S V Instructions and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product inspect contents of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify Simplex HAZARD Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Therefore handle as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times use the 553 484 Static Control Kit FREQUENCY ENERGY This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instruction manual may cause interference to radio It has been tested and found to comply with the limits for a Class A computing device pursuant Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such when operated in a commercial environment Operation of this equipment in a residential area may interference in which case the user at his own expense will be required to take whatever measures may be to correct the interference S V Operation 4903 TrueAlert Speaker Visible S V see Figure 1 is a wall mounted appliance that combines a TrueAlert strobe with a conventional when activated from a TrueAlert compatible control panel of a Simplex Fire Alarm System When the notification appliance emits and or light it indicates the possibility of an emergency situation that immediate attention strobe portion of the S V operates only on a TrueAlert compatible Signaling Circuit SLC The strobe is supervised via communications with the Addressable Controller rather than via conventional appliance Coded messages from the TrueAlert Addressable Controller turn strobe on and off The strobe can only be operated through a 4009 9401 Addressable Controller using Simplex TrueAlert Comm Channel speaker is a two wire appliance that operates only on a standard audio NAC 4100 4003 to reproduce amplified analog audio signals The speaker is and does not support audio wire T tapping The S V speaker circuit a 25Vrms or 70Vrms speaker line connection that can be configured to of four available audible power wattage levels W W 1 W 2 W The TrueAlert S V will not operate on a conventional NAC S Vs are available with strobes rated at 15 candela 75 candela and 110 candela Each model is available with a red white cover Table 1 lists the available S V models 1 TrueAlert S V 1 Wall Mount TrueAlert S V Models Description S V 15 CANDELA S V 75 CANDELA S V 110 CANDELA S V 15 CANDELA S V 75 CANDELA S V 110 CANDELA Model 4903 9350 4903 9351 4903 9352 4903 9353 4903 9354 4903 9355 Color Red White 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a trademark of Simplex Time Recorder Company or following an eight digit product ID number denotes ULC listed product D S V Wiring Make sure that all electrical power is disconnected before starting the installation Connect wiring to terminals as shown Break wire runs to provide supervision of connections Do not bring conduit through rear of the metal electrical box Strip lead insulation to 3 8 maximum At the metal electrical box connect contractor wiring to the STROBE and STROBE terminals and speaker wires to the SPKR and terminals at the rear of the S V Torque terminal block screws 12 15 in lbs to ensure proper continuity See Figure 2 Ensure that correct polarity is maintained for each S V Configure the speaker wattage setting using Table 2 Ensure that the RMS value of the connected audio circuit matches the RMS value the connected speaker An incorrect tap setting may damage the speaker The factory default setting for the speaker is J1 to Tap E W TrueAlert SLC and audio NAC wiring must be twisted pair TWP If audio NAC wiring is run in the same conduit with strobes 110CD then twisted shielded pair is required TERMINAL TERMINAL AUDIO NAC CHANNEL SEE NOTES TrueAlert COMPATIBLE CONTROLLER NOTES AUDIO NAC CHANNEL SEE NOTES TrueAlert COMPATIBLE CONTROLLER NOTES S V S V J1 tapped to E the Position Table 2 TERMINAL TERMINAL AND SPKR TERMINALS WIRES 12 18 AWG TWP NOTES 2 TrueAlert Speaker Jumper Settings to Tap A to Tap B to Tap C to Tap D to Tap D to Tap E to Tap F to Tap G NEXT APPLIANCE OR NAC CHANNEL NOTES NEXT APPLIANCE OR SLC NOTES S V A Wiring See Notes S V S V B Wiring See Notes Maximum 43 strobe appliances per circuit Maximum 30 ohms wire resistance between strobe appliances Refer to the Field Wiring Diagrams the driving TrueAlert compatible Fire Alarm Control Panel for further instructions Notification appliances are rated per individual nameplate label Maintain correct polarity on terminal connections Do not loop wires under terminals All TrueAlert SLC and NAC wiring connections are supervised and power limited appliances were only tested to the operating voltage limits of 17V to 31V Do not operate these appliances outside these limits doing so cause appliance to fail to operate as intended and or cause permanent damage to this equipment TrueAlert S V can only be operated through a compatible TrueAlert Addressable Controller is not allowed for Class A wiring 2 TrueAlert S V Wiring the TrueAlert S V Figure 3 for wall mounting the TrueAlert S V to the metal enclosure box When surface mounting the S V either the or 4905 9947 TrueAlert Surface Mount Skirt is required Refer to the 4905 TrueAlert Skirt Installation 574 790 for this mounting application mounting the S V to a Simplex 2975 9145 electrical box the 4905 9903 Adapter Plate is required Refer to the 4905 Adapter Plate Installation Instructions 574 791 for this mounting application Do not bring conduit through the rear of the metal electrical box Mount TrueAlert S V appliance onto metal electrical box making sure to route the audio NAC and SLC controller wiring the center of metal electrical box see Figure 3 Carefully centering the wires in the box will prevent the sharp edges the box from scraping the wire insulation Tighten mounting screws snugly do not over tighten Torque mounting screws 5 7 in lbs For semi flush mounting install the metal electrical box either flush with the wall or with a maximum recess SCREW HOLES FOR SQUARE MOUNTING SCREWS SUPPLIED NOTES 1 and 2 SCREW HOLES FOR SQUARE MOUNTING SCREWS SUPPLIED NOTES 1 and 2 SWITCH SW1 INDICATED BY DOTTED LINES NOTE 3 SQUARE METAL ELECTRICAL BOX INCHES DEEP 1 INCH EXTENSION RING INCHES DEEP MINIMUM NOTE 1 FROM 748 472 GROUP QTY 2 SCREWS CORNER S V COVER THE AUDIO NAC AND WIRING INSIDE THE METAL ELECTRICAL BOX NOTE 3 TrueAlert S V atta

Related Files