Simplex 4904 Series Wall Mount Rectangular Strobe, selectable as Free-Run or Synch SmartSync (B) (C) (D)

File Preview
File Preview
Click below to download for free

Text Preview

CSFM Listed NYC Acceptance Notification Appliances Wall Mount Visible Notification Appliances as Free Run or Synchronized Flash Rate flashtube visible notification appliance Models are available with 15 30 or 110 candela 24 VDC operation with switch selection for or synchronized flash rate also with SmartSync strobe operation Compatible with ADA requirements refer to installation information on page 3 Strobe candela rating is clearly indicated on Diode polarized input for connection to reverse supervised Notification Appliance Circuit Rugged high impact flame retardant housing UL listed to Standard 1971 flash rate mode for use with Simplex fire alarm control panel NACs that strobe synchronization or SmartSync appliance two wire control Separate Synchronization modules for Class B Y or Class A Style Z operation SmartSync Control Module 4905 9938 options Red with white lettering for vertical or wall mount White with red lettering for vertical wall Red wire guard is available 4904 Series wall mount visible notification provide symmetrical light output in key axis by utilizing a compound multi surface The lens assembly fits securely into its housing a high integrity notification appliance that is and vandal resistant and suitable for a variety of Refer to page 2 for guard listing This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 248 for allowable values and or conditions material presented in this document It is subject to re examination revision possible cancellation Accepted for use City of New York Department of Buildings MEA35 93E This product was not ULC listed or FM approved as of document revision Additional listings may be applicable contact Simplex for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Westminster Mount Strobes are Available in Red or White for Mounting and in Red for Horizontal Mounting Strobes multiple strobes and their reflections can be from one location synchronized flashes reduce the of photo sensitive reactions as well as the and possible distraction of random flashing If output NACs are not available two wire circuit Synchronization Modules can be used to control flash strobes Refer to data sheet for additional details Free run model will flash in a free run mode when connected to a NAC Selection selection of wall mount visible notification is dependent on occupancy location local and proper applications of the National Fire Code NFPA 72 ANSI A117.1 the appropriate building code BOCA ICBO or SBCCI and the guidelines of the Americans with Disabilities ADA Two wire synchronization circuit operation is protected by U S Patent No 5,559,492 horn strobe operation is protected under U S Patent No 6,281,789 9 2009 SmartSync Control Reference operation mode allows a two wire circuit to the ability to activate both the horn and strobe on same NAC and then allow the horn to be silenced the strobe remains flashing The horn operates as while the strobe operation is SmartSync Control Sources two wire control is available from 4006 4008 4100U and 4010 Fire Alarm Control refer to individual product data sheets for more 4009 IDNet NAC Extenders refer to data sheet SmartSync Control Module SCM Model 4905 9938 to data sheet S4905 0003 Product Selection Mount Visible Notification Appliances Strobes Output Rating cd cd cd Style with white lettering with red lettering with white lettering mount adapter plate zinc plated see illustration on page 4 Modules refer to data sheet S4905 0003 for additional details Flash Module B Style Y operation Flash Module A Style Z operation encapsulated with in out AWG 0.82 mm2 wire leads for 2 A NAC requires 5 mA for Control Module Class A or Class B Style Z Y installs in square box x 4 1 8 x 1 1 4 D mm x 105 mm x 32 mm Guard see illustration on page 4 Wire Guard UL listed by Space Age Electronics Inc x 4 3 8 x 2 7 8 deep mm x 111 mm x 73 mm wall mount wall mount x 3 1 8 mm x 79 mm x 2 7 16 x 13 16 mm x 62 mm x 20 mm 9 2009 Specifications Specifications Voltage Range Dimensions including lens Range Range 24 VDC see Note 1 below x 2 5 16 x 2 5 8 D 121 mm x 75 mm x 67 mm to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two per terminal for in out wiring Specifications Rate and Synchronized NAC Loading RMS Current Rating per Strobe Output Note 2 below Currents other voltages VDC VDC Hz with up to 35 synchronized strobes maximum per NAC cd mA mA mA cd mA mA mA cd mA mA mA 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1971 Signaling Devices for the Impaired changes effective May 1 2004 This voltage range is the absolute operating range Operation outside this range may cause permanent damage to the appliance Please note that 16 VDC is the lowest operating voltage is allowed at the last appliance on the NAC under worst case conditions The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage and the maximum current rating occurs at the lowest allowable operating voltage RMS is root mean square and refers to the value of a varying current waveform Semi Flush Installation Vertical Shown Rotate for Horizontal Mount Models gang box 2 1 2 mm deep RACO 519 or supplied by others INSTALLATION HEIGHT REFERENCE 72 requires that the entire lens not less than 80 and not greater 96 above the finished floor 9 2009 Surface Mounting Reference Vertical Shown Rotate for Horizontal Mount Models box 1 1 2 38 mm deep 650 or equal supplied by others gang box V5744S 57 mm deep by others Adapter Plate required for surface with handy box optional for semi flush Optional 4905 9926 Guard Rotate for Horizontal Mount Models is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo IDNet and SmartSync are trademarks of Tyco Ltd and its affiliates and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA is a trademark of the Wiremold Company 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 9 2009

Related Files