Simplex 4904 TrueAlert Non-Addressable SmartSync Strobe Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

4904 TrueAlert Non Addressable Strobe Instructions and Warnings NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product inspect contents of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify Simplex HAZARD Disconnect electrical power when making any internal adjustments or repairs should be performed by qualified Simplex Representatives HAZARD Static electricity can damage components Therefore handle as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times use the 553 484 Static Control Kit FREQUENCY ENERGY This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instruction manual may cause interference to radio It has been tested and found to comply with the limits for a Class A computing device pursuant Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such when operated in a commercial environment Operation of this equipment in a residential area may interference in which case the user at his own expense will be required to take whatever measures may be to correct the interference Non Addressable SmartSync Strobe Operation 4904 TrueAlert SmartSync Strobes see Figure 1 are non addressable wall Notification Appliances that provide a Visible Only V O warning of an alarm condition when activated from the control panel of a UL Simplex Fire Alarm System When the Notification Appliance emits light indicates the possibility of an emergency situation that requires your attention Strobe is a Notification Appliance that operates on a reverse polarity Appliance Circuit NAC When this NAC is in the reverse polarity or state these appliances do not operate and present a high impedance to circuit They operate their notification appliance actuators when the NAC polarity entering the state wall mounted Strobe activates a high intensity pulsed light output at a rate that determined by strobe configuration The Strobe configuration to a synchronization signal received from the NAC The appliance flashes when it detects either SmartSync or standard Simplex NAC signals The SmartSync Strobe can only be operated through a SmartSync Control Module SCM 4905 9914 9922 Strobe Sync Unit 4010 Alarm Control Panel FACP or 4009 IDNet NAC Extender The Strobe has been tested and found to comply with the FCC 15J rules for a Class A computing device are 3 models of each version of the Strobe each has a different light output rating 15 candela 75 candela and 110 candela Strobes available in red and white color versions Tables 1 and 2 describe Strobe features and current rates 1 TrueAlert Strobe 1 Wall Mounted TrueAlert Non Addressable Strobe Feature Chart WIRE V O 15 CANDELA WIRE V O 75 CANDELA WIRE V O 110 CANDELA WIRE V O 15 CANDELA WIRE V O 75 CANDELA WIRE V O 110 CANDELA ID PID NUMBERS COVER COLOR 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice and SmartSync are trademarks of Simplex Time Recorder Company B Non Addressable Strobe Wiring Make sure that all power is disconnected before starting the installation Connect wiring to terminals as shown Do not loop wires under terminals Break wire runs to provide supervision of Do not bring conduit through the rear of the electrical box Strip lead insulation to 3 8 maximum At the enclosure box run contractor wiring through the cutout slot and connect the wires to the NAC and NAC terminals at the the Strobe unit See Figure 2 When connecting more than one Strobe to a circuit ensure that correct polarity is maintained on each Strobe unit When connecting the last Strobe on a circuit connect an end of line resistor EOLR to the Strobe terminals SLOT FOR WIRING AWG NOTES 2 INPUT 1 INPUT TERMINALS ACCEPT WIRES 12 18 AWG VDC POWER INPUT NOTE 4 16 33 VDC NON CODED APPLIANCE OR PRECEEDING NOTES LAST APPLIANCE ON CONNECT EOLR NOTES STROBE STROBE STROBE Notification Appliances are rated per individual nameplate label Maintain correct polarity on terminal connections Do not loop wires under terminals Refer to the Field Wiring Diagrams supplied with the FACP for detailed NAC wiring information appliances were only tested to the operating voltage limits of 16VDC and 33VDC Do not operate appliances outside these limits doing so may cause appliance to fail to operate and or cause damage to this equipment Maximum 35 appliances per circuit Maximum 30 ohms wire resistance between appliances to the Field Wiring Drawings of the driving Fire Alarm Control Panel for further instructions 2 TrueAlert Strobe Wiring the TrueAlert Non Addressable Strobe Figure 3 for mounting the Strobe to the enclosure box When surface mounting the Strobe the 4905 9937 or 4905 9940 TrueAlert Mount Skirt is recommended Refer to the 4905 TrueAlert NAC Surface Mount Skirt Installation Instructions 574 790 for this application Do not bring conduit through the rear of the electrical box Tighten mounting screws snugly do not over tighten For semi flush mounting install the box either flush with the wall or with a maximum 0.25 inch recess HOLES FOR MOUNTING NOT SUPPLIED NOTES 1 and 2 SQUARE BOX SUPPLIED NOTES 1 and 2 HOLES FOR MOUNTING NOT SUPPLIED NOTES 1 and 2 HOLES FOR 4 SQUARE MOUNTING SUPPLIED NOTES 1 and 2 FROM 748 472 GROUP 2 SCREWS CORNER COVER NOTE 3 TrueAlert Strobe attaches directly to standard single gang double gang or 4 inch square box s not supplied mounted semi flush or surface to the wall surface are two holes for single gang and double gang electrical box mounting secure the to the single gang or double gang box using two mounting screws 6 32 x 1 1 8 inch not supplied The two mounting screws are placed cross corner opposite top and bottom for the double gang installation remove cover press snap release in one at a time with a flat tip screwdriver while pulling cover with other hand 3 TrueAlert Strobe Mounting Table 2 TrueAlert Strobe Units Current Rating Chart VDC mA mA Avg mA Safety and Placement of Notification Appliances Appliances and the Fire Alarm System itself have certain limitations and requirements for safety placement installation test Since you must know the limitations and adhere to the requirements keep these instructions at a central location for future so that all people who use maintain and test the Fire Alarm System have access to this information Appliances do not sense any hazardous conditions such as smoke fire explosion etc they are activated by a control panel part of a system that does sense such conditions Appliances do not provide their own power They receive their power from the Fire Alarm System If power is not to the Notification Appliances for whatever reason the Notification Appliances will not provide a visible warning BACK UP POWER SUPPLIES OR OTHER BACK UP POWER SO

Related Files