Simplex 4905-9816, 4905-9817, 4905 -9818 TrueAlert Addressable Adapter Module (G)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4905-9816-4905-9817-4905-9818-truealert-addressable-adapter-module-g-9805173426.pdf |
---|---|
Type | |
Size | 715.11 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances TrueAlert Addressable Adapter Module Model 4905 9816 a single TrueAlert addressable address into separate 24 VDC and visible notification outputs Power and communications are supplied by advanced notification controlled by IDNAC Line Circuits SLCs from Simplex fire alarm control panel EPS EPS power and 4009 IDNAC Repeaters Operation is also compatible with legacy TrueAlert from TrueAlert Power Supplies TPS or Addressable Controllers 4009T Up to two TrueAlert Addressable Adapter Modules be connected to one IDNAC SLC control output features Operation modes are visible and audible appliances on or visible appliance only with activation by the control panel IDNAC SLC On board circuit limits appliance inrush current and self resetting overcurrent protection Wiring to audible and visible appliances is supervised conventional reverse polarity operation opens or are reported to the control panel output ratings Regulated 24 DC appliance power audible output is for up to 30 mA visible output is rated for up to mA Special Applications appliance ratings audible output rated for up to 50 mA visible output is rated for up 250 mA diagnostics A visible status LED can be programmed at the control panel to indicate polling status and be activated per address for module testing mechanical features Mounts in standard 4 11 119 mm square electrical Cover plates required are available for surface or mount ordered separately Cover plates provide status LED viewing Screw terminals for wiring connections listed to Standard 864 This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Accepted for use City of New York Department of Buildings MEA35 Additional listings may be applicable contact your local Simplex product supplier the latest status Listings and approvals under Simplex Time Recorder Co are the of Tyco Fire Protection Products Use of in this document refers to both TrueAlert and TrueAlert ES notification Use of IDNAC SLCs also refers to operation of TrueAlert SLCs appliance Addressable appliance SLC with Class B wiring Control Panel EPS Power Supply Addressable Adapter Module One Line Wiring Reference Notification Requirements IDNAC SLCs addressable TrueAlert horns and or strobes in to commands received from the IDNAC SLC applications where appliances other than the standard addressable appliances are required the Addressable Adapter Module provides a audible and visible output individually activated the IDNAC SLC applications are for connection to special appliances appliances with particular output characteristics special bells or chimes or connection to appliances that are required to satisfy aesthetic requirements TrueAlert Addressable System With the TrueAlert Addressable Adapter non TrueAlert appliances can be controlled still benefiting from the TrueAlert addressable active supervision to the Adapter Module diagnostic modes and supporting of B wiring of the IDNAC SLC connections additional information refer to Installation 579 390 5 2013 Appliance Wiring Details with circuit protectors When to remote appliances up to 200 ft from the that exit the building and may be exposed to electrical environments the notification appliance is compatible with Simplex circuit protectors protectors are listed on page 3 and should be both where the wiring leaves the building and it connects to the appliances for shielded wire For applications where appliance wiring may be exposed to electrical twisted shielded wiring is recommended The wiring terminal block has provisions for the shield s TrueAlert Addressable Adapter Product Selection TrueAlert Addressable Adapter Module requires surface or flush mount cover plate End of Line Resistor Harness ref 733 894 10 k W two required one each for audible and visible Surface Mount Cover Plate Flush Mount Cover Plate select one for each 4905 9816 per application painted beige TrueAlert Addressable Adapter Installation Reference plate depth 9 mm for surface mounted box 6 mm for flush mounted box 119 mm square box 2 51 mm depth ref RACO 257 2 1 8 mm deep or equal supplied by others LED Addressable Module Assembly pipe for viewing 133 mm holes cover plate 4 block for connections for connecting mounting box 4 mm into box 33 mm mode switch Addressable Module Detail 2 3 4 5 6 7 8 POWER SERVICING 127 mm 5 2013 Specifications and Operation Reference Voltage Current SLCs 23 to 31 VRMS TrueAlert SLCs 17 to 31 VRMS One unit load and power are supplied from the SLC Address Requirements Voltage NAC Ratings Output Mode Control Output Mode Control with 24 DC Appliances with Application Appliances 24 DC Power Ratings Application Ratings 450 mA maximum adapter and appliances Address per Adapter Module limited to two Adapter Modules per SLC to 32 VDC appliance inrush current is internally limited to 550 mA Output 30 mA Output 180 mA Output 50 mA Output 250 mA for free run or for Simplex strobe synch pulses synchronized to the SLC for continuous on or to follow same pattern as the SLC select continuous appliance has its own pattern selection or if it has high repetitive inrush current for appliances listed to UL Standard 1971 or UL Standard 464 use external synchronization modules where required Output Compatible with Simplex horns and with the horn of 4 wire horn strobes A V of free run not SmartSync operation with Simplex strobes and with the strobes of 4 wire horn strobes and 4 wire speaker strobes S V select output as sync mode Speaker circuits require separate wiring Output SLC Channel Loading Reference Addressable Adapter Modules per SLC Two maximum addresses unit loading SLC Strobe Loading maximum maximum to 63 addressable synchronized strobes maximum per IDNAC SLC to 46 addressable synchronized strobes maximum per TrueAlert SLC refer individual appliance and control panel information for additional information EPS Power Supply and 4009 IDNAC Repeater 3 A maximum Power Supply 3 A maximum Addressable Controller 2.5 A maximum ft maximum 61 m k W two required one located at each remote appliance use End of Line Resistor Harness ref 733 894 ordered separately terminals for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 Overvoltage Protector 200 mA maximum Isolated Loop Circuit Protector 5 A maximum Isolated Loop Circuit Protector 200 mA maximum 11 H x 5 W x 1 9 D 119 mm x 127 mm x 33 mm metal galvanized to 120 F 0 to 49 C adapter is intended to be mounted indoors to 90 RH non condensing at 90 F 32 C Curre