Simplex 4905-9835 Temporal Code 4 Module for CO Gas Alarm Notification (B)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4905-9835-temporal-code-4-module-for-co-gas-alarm-notification-b-4356180972.pdf |
---|---|
Type | |
Size | 726.17 KB |
Downloads |
Text Preview
ULC CSFM Listed Approved Temporal Code 4 TC4 NAC Notification Circuit control for Carbon Monoxide gas warning The TC4 CO gas warning is a repeated sequence of four of 100 msec on with 100 msec off followed by seconds off per NFPA 720 Standard for the of Carbon Monoxide CO Warning in Dwelling Units Compatible appliances includes CO Sounder Base 4901 9820 Horn set for free run and 4903 4 wire A V appliances horn input not compatible SmartSync horn control appliances Simplex equipment NAC sources 4100ES 4100U or 4010ES NAC outputs 4009 IDNet NAC Extender NAC outputs Each module requires an input NAC that powers the 3A output NAC for control of compatible audible appliances only not for strobes selectable operation modes Synchronized operation allows a separate and control NAC to both activate and synchronize Temporal Code 4 output timing of up to 20 modules Unsynchronized operation also allows the separate and control NAC to activate the Temporal Code 4 timing of up to 20 4905 9835 modules but synchronization between the modules Stand Alone operation allows the input NAC in alarm activate Temporal Code 4 timing for NACs dedicated CO gas alarm no fire alarm signals are available no NAC is used For both Synchronized and Unsynchronized modes the control NAC is off the module output NACs follow the fire alarm signals of the input NAC NOTE For TC4 output both the input NACs and the NACs requires a Steady On signal sealed construction Mounts in standard 4 square electrical box Screw terminals for wiring connections to UL Standard 864 and ULC Standard S527 CO gas alarm warnings are required to be different from alarm warnings In the event of a CO gas alarm the of a Temporal Code 4 audible signal pattern the type of condition to the responders to assist in the proper actions to be taken This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 328 allowable values and or conditions concerning material presented in this document This was not accepted by MEA NYC as of document revision date Additional listings be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection Peripherals 4905 9835 Temporal Code 4 for CO Gas Alarm Notification 2 Temporal Code 4 Module approximately 1 2 size Continued CO gas alarm or fire alarm Use of the 4905 9835 Code 4 Module allows the NFPA 720 Temporal 4 signal to be generated using a standard Steady On appliance NAC input Under the fire alarm panel the audible notification signal can be selected for a fire pulse pattern for a fire alarm condition or Temporal Code 4 pattern can be activated for a CO gas condition Control NAC Current NAC Current Distance input NAC Source Connections 24 VDC NACs up to 3 A limited by input NAC for control of audible appliances compatible TC4 code pulse duty cycle current 0.18 mA current 15 mA current 0 mA current 3 mA close nippled 20 ft 6 m distance terminals for in out wiring to 12 AWG wire to 3.31 mm2 x 4 x 1 D mm x 105 mm x 35 mm metal galvanized Plate Range 32 to 120 F 0 to 49 C for indoor operation to 93 RH at 100 F 38 C Range 4 2013 System Connection Reference control NAC input to TC4 3 A maximum Temporal Code 4 TC4 Module CO Sounder Horn 4903 Series 4 wire A V horn other compatible not SmartSync control VDC audible notification appliances 2 N 2 N NAC output 3 A maximum control NAC to the next Temporal 4 Module up to 20 total maximum requires resistor per source NAC requirements NACs require resistor per NAC requirements Note IDNet communications wiring not shown is required to connect to each 4098 9798 CO Sensor Sounder Base Fire Alarm Control Panel shown for reference or RUI Communications system requirements N SCO NNECT W ER RE SERVI CI NG 4009 IDNet NAC EXTENDER M IDNet NAC Extender shown uses IDNet or Remote 4100ES MINIPLEX with NACs uses RUI communications Mounting Reference Box supplied separately 4 square mm minimum depth 2 1 8 54 mm 232 or equal Additional Reference 4 square cover plate RACO 752 equal supplied separately Instructions Sensor Base data sheet Basic Reference Control Panel Horns Series 4 wire A Vs SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA is a trademark of the National Fire Association 2013 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 4 2013