Simplex 4905-9996CA, 617-343 4905 Series Insuite Device Distribution Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4905-9996ca-617-343-4905-series-insuite-device-distribution-module-1526734089.pdf |
---|---|
Type | |
Size | 645.00 KB |
Downloads |
Text Preview
Listed Supports Supervised Operation Provides short circuit isolation Support for 24 VDC or 25 VAC NACs Up to 2 Insuite device circuits per 4905 9996CA Fully compatible with standard non Insuite dedicated Style Z Class B NAC compatibility Compatible with 4901 Series Insuite Silenceable refer to data sheet S4901 0015 for additional For surface mounting in a 4 11 electrical box cover is 4905 9996CA Insuite Device Distribution Module is integral part of providing a robust and cost effective to meet audible appliance requirements for units as specified in various building codes unit is designed to comply with requirements that any tampering with insuite devices including open grounded circuit or short circuit will not affect operation of any other devices located in other suites 4905 9996CA accepts input from a Fire Alarm NAC to Simplex 4901 Series Insuite Silenceable located in the suites and has an output back to the Alarm NAC The 4905 9996CA is usually field as they are housed in 4 11 16 square electrical Depending upon which building code compliance required the insuite device circuits are run from the in either Class or Class 4905 9996CA connects to a 24 VDC or 25V Audio and provides full supervision beyond the module Reference to Installation Instructions 579 1008 for additional Appliances Insuite Device Module Box with ring Module included Insuite Device Distribution Module Reference and extension ring are supplied separately VDC Regulated mA VRMS mA Voltage Current Voltage Current of Insuite Silence Devices Distribution Module of Distribution per Fire Alarm Load Per Suite Box Dimensions Connections Watts 25 VRMS 80 mA 24 VDC 11 square box 2 with 1 extension 15 125 mm square terminals for input output wiring to 14 AWG wire mm2 to 2.08 mm2 Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 11 2011 Application Diagrams Audio Application Distribution and Insuite Silence Modules B Supervision VAC Circuit Supervised Circuit Supervised non Insuite Fire Alarm Device Device Resistor 10K Ohms VDC VDC VDC VDC VAC VAC VAC VAC VAC VAC VAC VAC 1 2 V Audio Operation 3 4 V Audio Operation When the 4901 9838CA 4901 9839CA silence switch is used in conjunction with slave speakers this 24 VDC power source provided by the Fire Alarm Panel must be interrupted during use of the fire alarm microphone diagram provides an applications overview not all wiring is shown For detailed wiring connection information refer to Installation Instructions 579 Distribution Modules and 579 1009 Insuite Silenceable Devices Note The 4905 9996CA does not accept an input from a 70V Audio NAC Distribution and Insuite Silence Modules Application B Supervision VDC Circuit Supervised Circuit Supervised non Insuite Fire Alarm Device Device Resistor 10K Ohms VDC VDC Audible Audible Audible Audible 1 2 Operation 3 4 Operation diagram provides an applications overview not all wiring is shown For detailed wiring connection information refer to Installation Instructions 579 Distribution Modules and 579 1009 Insuite Silenceable Devices SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited Fire Protection Products Westminster MA 01441 0001 USA 11 2011 2011 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice