Simplex 4906-0002 (4906-9127 is tested on 4010 panel)

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4906-0002-4906-9127-is-tested-on-4010-panel-5947830126.pdf
Type PDF
Size 776.22 KB
Downloads

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Multi Candela Notification Appliances Operation Audible Visible Notification Horn and Synchronized Flash Non Addressable A V notification appliances with electronic horn and high output xenon available for wall or ceiling mount Operation is compatible with ADA requirements refer important installation information on page 3 Rugged high impact flame retardant thermoplastic are available in red or white with clear lens over a two wire SmartSync circuit to Horns that are controlled separately from strobes on the and operation on two wire circuit same two wire pair SmartSync horn activation of Temporal pattern March pattern at 60 BPM or on continuously Strobe appliances on the same circuit operating at a 1 Hz flash rate Class B Style Y operation requires connection to a SmartSync NAC or to SmartSync Control SCM 4905 9938 Class A Style Z operation when connected to the SCM or with 4100U series fire alarm control NACs mount A Vs features Wiring terminals are accessible from the front of the providing easy access for installation and testing Covers are available separately to convert housing color Available UL listed sound damper for locations attenuation of 5 to 6 dBA stairwells small highly reverberant areas etc adapters and wire guards Wall mount A V adapters are available to cover surface electrical boxes and to adapt to Simplex boxes UL listed red wire guards are available for wall or mount A Vs notification appliance strobe 24 VDC xenon strobe intensity is selectable as 15 30 or 110 candela with visible selection jumper secured strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output provides controlled inrush current notification appliance horn Low current 24 VDC electronic horn with harmonically sound output suitable for either steady or coded Temporal or 60 BPM March Time pattern UL listed to Standard 464 and Ceiling Mount A Vs TrueAlert A Vs with horn and strobe provide convenient installation standard electrical boxes The enclosure designs are impact and vandal resistant and provide a convenient intensity selection Since each model can be for strobe intensity output on site model is minimized and changes encountered during can be easily accommodated mount A V housings are a one piece assembly lens that mounts to a single or double gang or square standard electrical box The cover can be removed a tool is required and covers are separately for color conversion mount A Vs install using standard 4 electrical Color choice is determined by model number Intensity Selection installation a selection plug at the back of the determines the desired strobe intensity An flag with black letters on a highly visible yellow allows the selected intensity to be seen at the of the strobe lens This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Refer to page 2 for listing of wire guards Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster Simplex multi candela SmartSync two wire horn strobe appliance operation is protected one or more of the following U S Patent Numbers 5,559,492 5,622,427 5,886,620 6,281,789 6,954,137 7,005,971 and 7,006,003 12 2007 Strobe Application Selection selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Strobes Strobes When multiple strobes and their can be seen from one location synchronized reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of flashing The multi candela strobes of these A Vs synchronized by the controlling SmartSync operation SmartSync Two Wire Control operation mode allows a two wire circuit to the ability to activate both the horn and strobe on same NAC and then allow the horn to be silenced the strobe remains flashing The horn operates as while the strobe operation is SmartSync Control Sources 4006 4008 4100U and 4010 Fire Alarm Control refer to individual product data sheets for more 4009 IDNet NAC Extender refer to data sheet SmartSync Control Module SCM 4905 9938 refer to sheet S4905 0003 SmartSync compatible notification include separate horns and combination notification appliances Product Selection A Vs Wall Mount A V Accessories Color Lettering Description with Multi Candela Strobe strobe intensity selectable as 30 75 or 110 candela operates with SmartSync two wire Red White Red Adapter Plate for mounting to Simplex 2975 9145 box typically for Mount Adapter Skirt use to cover 1 1 2 38 mm deep mounted boxes may be mounted vertical or horizontal Red Mounting Box requires Adapter Plate 4905 9931 Sound Damper package of 20 field installed adhesive backed output attenuator reduces output 5 to 6 dBA After Sound Damper installation measure sound level to ensure with applicable code requirements Control Module SmartSync Control Module with Class B or Class A output mounts in 4 Covers for Wall Mount A Vs mm square box refer to data sheet S4905 0003 for details Red cover with white lettering White cover with red lettering Guards and Ceiling Mount A V Adapter Wall mount red wire guard with mounting plate compatible with semi flush surface mounted boxes UL listed by Space Age Electronics Inc Wire Guard for mounting to flush mounted electrical box Adapter Plate required to mount guard to surface electrical box Mount Adapter Box Extension use to cover deep surface mounted boxes H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm with strobe 4 3 8 111 mm x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 D mm x 130 mm x 70 mm Diameter 44.5 mm 0.31 8 mm sound opening x 4 1 8 x 1 1 4 D mm x 105 mm x 32 mm H x 5 W x 1 1 2 D mm x 127 mm x 38 mm H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm x 6 1 8 x 3 mm x 156 mm x 76 mm x 7 mm x 178 mm x 6 7 8 x 1 1 2 deep 121 mm x 175 mm x 38 mm 12 2007 A V Specifications Mount or Ceiling Mount Common Specifications Voltage Range Listed Rating Regulated 24 DC see Note 1 below Listed Rating 20 VDC to 30 VDC per ULC S526 M878 Rate and Synchronized NAC Loading

Related Files