Simplex 4906-9101, -9102, -9103, -9104 Multi-Candela V O (strobe); Wall and Ceiling Mount (B) (C) (D)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4906-9101-9102-9103-9104-multi-candela-v-o-strobe-wall-and-ceiling-mount-b-c-d-8429036751.pdf |
---|---|
Type | |
Size | 740.17 KB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Approved NYC Acceptance Multi Candela Notification Appliances Notification Appliances with Synchronized Flash SmartSync Operation Compatible only V O 24 VDC notification appliances high output xenon strobe available for wall ceiling mount is selectable as 15 30 75 or 110 candela with selection jumper secured behind strobe housing Operation is compatible with ADA requirements refer important installation information on page 3 Polarized input allows connection to compatible reverse supervised notification appliance circuit NAC Regulated circuit design ensures consistent flash output provides controlled inrush current Rugged high impact flame retardant thermoplastic are available in red or white with clear lens Listed to UL 1971 and ULC S526 provide synchronized flash for use with 4006 4008 4010 and 4100U Series fire alarm control with NACs selected to provide strobe or SmartSync two wire control 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are for Class B or Class A operation Separate SmartSync Control Modules SCMs that Class B or Class A output from conventional inputs housings provides flexible easy and semi flush or surface wall mounting Rear of housing does not extend into box Wall mount strobes easily mount to single gang double or 4 inch square outlet box Ceiling mount strobes mount to single gang boxes mount strobe features Wiring terminals are accessible from the front of the providing easy access for installation and testing Covers are available separately to convert housing color adapters and wire guards Wall mount strobe adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes UL listed red wire guards are available for wall or mount strobes Refer to page 2 for guard listing This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 316 for allowable values and or conditions concerning presented in this document It is subject to re examination revision and possible Refer to page 2 for listing status of wire guards Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Mount Strobes Mount Strobes Multi Candela TrueAlert synchronized strobes convenient installation to standard electrical The enclosure designs are both impact and vandal and provide a convenient strobe intensity Since each model can be selected for intensity on site model inventory is minimized and changes during construction can be easily mount strobe housings are a one piece assembly lens that mounts to a single or double gang or square standard electrical box The cover can be removed a tool is required and covers are separately for color conversion mount strobes install using standard single gang boxes Color choice is determined by model Intensity Selection installation a selection plug at the back of the determines the desired strobe intensity An flag with black letters on a highly visible yellow allows the selected intensity to be seen at the of the strobe lens Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Simplex multi candela SmartSync two wire horn strobe appliance operation is protected one or more of the following U S Patent Numbers 5,559,492 5,622,427 5,865,527 6,281,789 6,954,137 7,005,971 and 7,006,003 9 2009 Synchronized Strobes Strobes When multiple strobes and their can be seen from one location synchronized reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of flashing These multi candela strobes are over a two wire circuit when connected to NACs to compatible Synchronized Flash or to SmartSync Control Modules Two Wire Control applications desire the audible notification to be capable of being silenced before the condition is reset on until silenced while the notification appliances are kept activated until the condition is reset on until reset SmartSync mode provides this function using a single two wire operation SmartSync Control Sources two wire control is available from 4006 4008 4100U and 4010 Fire Alarm Control refer to individual product data sheets for more 4009 IDNet NAC Extenders refer to data sheet SmartSync Control Module SCM Model 4905 9938 to data sheet S4905 0003 SmartSync compatible notification include separate horns and combination notification appliances strobe with intensity selectable as 30 75 or 110 candela synchronized flash rate two wire control compatible Product Selection Visible Notification Appliances Strobes Color Wall Mount Strobe Adapters Lettering Description Red White Red Adapter Plate for mounting to Simplex 2975 9145 box typically for Mount Adapter Skirt use to cover 1 1 2 38 mm surface mounted boxes may be mounted vertical or horizontal Red Mounting Box requires Adapter Plate 4905 9931 Mount Strobe Adapter Surface Mount Adapter Plate zinc plated required for mounting to Modules refer to data sheet S4905 0003 for additional information box not needed when using 4905 9926 guard Class B Class A SmartSync Control Module with Class B or Class A output mounts in Flash Module epoxy encapsulated with 18 AWG 0.82 mm2 wire leads rated for 2 A NAC 5 mA for power 102 mm square box Covers and Guards Red cover with white lettering White cover with red lettering Wall mount Ceiling mount UL listed by Space Age Electronics Inc Wall mount strobes wire guard with mounting plate compatible with or surface mounted boxes H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm depth with strobe 4 3 8 111 mm x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 D mm x 130 mm x 70 mm x 3 1 8 x 0.060 D mm x 79 mm x 1.5 x 2 7 16 x 13 16 mm x 62 mm x 20 mm x 4 1 8 x 1 1 4 D mm x 105 mm x 32 mm H x 5 W x 1 1 2 D mm x 127 mm x 38 mm H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm x 4 3 8 x 2 7 8 deep mm x 111 mm x 73 mm 9 2009 Strobe Specifications Mount or Ceiling Mount Common Specifications Voltage Range Rate NAC Loading Range Range Dimensions with lens RMS Current Rating per Setting see Note 2 below RMS Currents other voltages Dimensions with lens RMS Current Rating per Setting see Note 2 below RMS Currents other voltages VDC VDC VDC VDC cd mA mA mA cd mA mA mA 24 VDC see Note 1 below Hz