Simplex 4906-9107, 4906-9108 TrueAlert Multi-Candela Notification Appliances, Non-Addressable Visible Only (V O) Amber Lens Strobes for Emergency Communications (C) (F) (D)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Multi Candela Notification Appliances Visible Only V O Amber Lens for Emergency Communications only V O 24 VDC wall mount notification with high output xenon strobe Amber lens with lettering produces a signal from clear lens fire alarm evacuation strobes for with Emergency Communications Systems is selectable as 15 30 75 or 110 candela with selection jumper secured behind strobe housing UL listed to Standard 1638 due to non white lens by UL testing to provide light dispersion of UL Standard 1971 at rated candela no necessary for amber lens ULC listed to Standard S526 Polarized input allows connection to compatible reverse supervised notification appliance circuit NAC Regulated circuit design ensures consistent flash output provides controlled inrush current Rugged high impact flame retardant thermoplastic are available in red or white with amber lens Refer to important installation information on page 3 provide synchronized flash for use with 4100ES 4100U and 4010 Series fire alarm control with NACs selected to provide strobe or SmartSync two wire horn strobe 4009 IDNet NAC Extenders Separate strobe synchronization modules that are for Class B or Class A operation Separate SmartSync Control Modules SCMs that Class B or Class A output from conventional inputs NOTE Connect amber strobes to NACs dedicated for Communications operation not for fire notification housings provides flexible easy and semi flush or surface mounting Rear of housing does not extend into box Strobes easily mount to single gang double gang or square outlet box Wiring terminals are accessible from the front of the providing easy access for installation and testing adapters and wire guard Strobe adapters are available to cover surface mounted boxes and to adapt to Simplex 2975 9145 UL listed red wire guard Refer to page 2 for listing status of wire guards This product has been approved by the State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health Safety Code See CSFM Listing 7300 0026 326 for allowable values and or conditions material presented in this document It is subject to re examination revision and cancellation FM approval and MEA acceptance are not applicable Additional may be applicable contact your local Simplex product supplier for the latest status and approvals under Simplex Time Recorder Co are the property of Tyco Safety Westminster Lens Wall Mount Strobes amber lens multi candela strobes non fire alarm alert notification for use with Communications systems where additional information is provided by audio or textual housings are a one piece assembly including that mounts to a single or double gang or 4 square electrical box The cover can be quickly a tool is required and the enclosure design is and vandal resistant Output During installation a selection at the back of the housing determines the desired intensity An attached flag with black letters on a visible yellow background allows the selected to be seen at the side of the strobe lens Application Reference strobes used as part of an Emergency system are located to provide the same coverage as required of clear lens fire alarm strobes Emergency Communications requirements are in detail in document UFC 4 021 01 USA of Defense United Facilities Criteria and in 72 Chapter 24 2010 and 2013 editions strobe coverage criteria is further described in the Fire Alarm and Signaling Code NFPA 72 A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines the Americans with Disabilities Act ADA 1 2013 Synchronized Strobes Strobes When multiple strobes and their can be seen from one location synchronized reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of flashing These multi candela strobes are over a two wire circuit when connected to NACs to compatible Synchronized Flash or to SmartSync Control Modules Two Wire Control Reference Alarm Operation SmartSync two wire control separate horn and strobe control over the same This allows audible notification appliances to be of being silenced before the alarm condition is on until silenced while the visible notification are kept activated until the alarm condition is on until reset Operation When non addressable amber strobes used to provide alert indications audible information provided by a voice audio system or other unique alarm signaling Refer to the Additional Product list to the right for associated products applications requiring multiple NAC may require amber strobe control from 4905 9938 SmartSync Control Modules Additional Product Reference Clear Lens Strobes strobe horn strobe speaker strobe Notification Modules and Panels and SmartSync Control Modules IDNet NAC Extender Fire Alarm Control Panels Fire Alarm Panels Fire Alarm Audio Equipment Series Emergency Voice Alarm Equipment Panel with 4010 control panels Reference Instructions Sheet strobe with amber lens intensity selectable as 15 30 75 or candela synchronized flash rate SmartSync two wire control Visible Notification Appliances Strobes Lettering Description Color Product Selection Adapters Red White Red Adapter Plate for mounting to Simplex 2975 9145 box typically Mount Adapter Skirt use to cover 1 1 2 38 mm surface mounted boxes retrofit may be mounted vertical or horizontal Red Mounting Box requires Adapter Plate 4905 9931 Modules refer to data sheet S4905 0003 for additional information Class B Class A SmartSync Control Module with Class B or Class A output mounts in Flash Module epoxy encapsulated with 18 AWG 0.82 mm2 wire leads rated for 2 A NAC 10 mA for power 102 mm square box H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm depth with strobe 4 3 8 111 mm x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 D mm x 130 mm x 70 mm x 2 7 16 x 13 16 mm x 62 mm x 20 mm x 4 1 8 x 1 1 4 D mm x 105 mm x 32 mm Guard UL listed by Space Age Electronics Inc Red wire guard with mounting plate compatible with semi flush or mounted boxes H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm 1 2013 Strobe Specifications Range Rate NAC Loading Range Range 24 VDC see Note 1 below Hz to 35 synchronized strobes maximum per NAC to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per for in out wiring H x 5 W x 2 3 4 D 130 mm x 127 mm x 70 mm Dimensions with lens RMS Current Rating per Strobe see Note 2 below RMS Currents at other 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1638 Visual Signaling Appliances cd mA mA mA cd mA mA mA cd mA mA mA VDC VDC cd mA mA

Related Files