Simplex 4906-9133, 4906-9134, 4906-9135, 4906-9136 SmartSync Operation Audible Visible Notification with Chime and Synchronized Flash, Non-Addressable (F)

File Preview
File Preview
Click below to download for free

Text Preview

cUL CSFM Listed Approved Multi Candela Notification Appliances Operation Audible Visible Notification Chime and Synchronized Flash Non Addressable notification appliances with mode electronic chime and high output strobe available for wall or ceiling mount Operation is compatible with ADA requirements to important installation information on page 3 Rugged high impact flame retardant thermoplastic are available in red or white with clear lens over a two wire Simplex SmartSync to provide Private mode chime tones controlled separately from on the same two wire circuit SmartSync chime activation of Temporal pattern Time pattern at 60 BPM or on continuously 60 BPM Strobe appliances on the same circuit operating at a 1 Hz flash rate Refer to page 2 for SmartSync control list and operation information mount chime strobes features Wiring terminals accessible from the front of the providing easy access for installation and testing Covers are available separately to convert housing color adapters and wire guards Wall mount adapters are available to cover surface electrical boxes and to adapt to Simplex boxes UL listed red wire guards are available for wall or mount chime strobes notification appliance strobe 24 VDC xenon strobe intensity is selectable as 15 30 or 110 candela with visible selection jumper behind strobe housing Regulated circuit design ensures consistent flash and provides controlled inrush current Listed to UL 1971 and to CSA standards for general use in Canada non fire alarm applications notification appliance chime Low current 24 VDC electronic chime with volume tone frequency adjustment Listed to UL 464 for private mode signaling and to standards for general signaling use in Canada alarm applications Refer to page 2 for guard listing This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7135 0026 335 for allowable values and or conditions material presented in this document It is subject to re examination revision possible cancellation Additional listings may be applicable contact your local product supplier for the latest status Listings and approvals under Simplex Recorder Co are the property of Tyco Safety Products Westminster and Ceiling Mount Chime Strobes TrueAlert chime strobes provide mode audible notification for applications requiring of trained personnel instead of the general Typical applications would be in medical patient where the softer chime tones are less disruptive than fire alarm audible notification designs are both impact and vandal resistant provide a convenient strobe intensity selection Since model can be selected for strobe intensity output model inventory is minimized and changes during construction can be easily Installation conveniently uses standard boxes mount chime strobe housings are a one piece including lens that mounts to a single or double or 4 square standard electrical box The cover can be removed a tool is required and covers are separately for color conversion mount chime strobe housings install using 4 electrical boxes Color choice is determined by number Intensity Selection installation a selection plug at the back of the determines the desired strobe intensity An flag with black letters on a highly visible yellow allows the selected intensity to be seen at the of the strobe lens Simplex multi candela SmartSync two wire chime strobe appliance operation is under one or more of the following U S Patent Numbers 5,559,492 5,865,527 5,886,620 6,281,789 6,954,137 7,005,971 and 7,006,003 4 2010 SmartSync Two Wire Control operation mode allows a two wire circuit to the ability to activate both the chime and strobe the same NAC and then allow the chime to be silenced the strobe remains flashing The chime operates as while the strobe operation is SmartSync Control Sources 4006 4008 4100U and 4010 Fire Alarm Control refer to individual product data sheets for more 4009 IDNet NAC Extender refer to data sheet SmartSync Control Module SCM 4905 9938 refer to sheet S4905 0003 SmartSync compatible notification include separate chimes and combination notification appliances Strobe Application Selection selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Strobes Strobes When multiple strobes and their can be seen from one location synchronized reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of flashing The multi candela strobes of these are synchronized by the controlling operation NAC Product Selection Chime Strobes Color Wall Mount Chime Strobe Accessories Lettering Description chime with Multi Candela Strobe strobe intensity as 15 30 75 or 110 candela operates with two wire control Red White Red Adapter Plate for mounting to Simplex 2975 9145 box typically for Mount Adapter Skirt use to cover 1 1 2 38 mm deep mounted boxes may be mounted vertical or horizontal Red Mounting Box requires Adapter Plate 4905 9931 Control Module SmartSync Control Module with Class B or Class A output mounts in 4 Covers for Wall Mount Chime Strobes mm square box refer to data sheet S4905 0003 for details Red cover with white lettering White cover with red lettering Guards and Ceiling Mount Chime Strobe Adapter Wall mount red wire guard with mounting plate compatible with semi flush surface mounted boxes UL listed by Space Age Electronics Inc Wire Guard for mounting to flush mounted electrical box Adapter Plate required to mount guard to surface electrical box Mount Adapter Box Extension use to cover deep surface mounted boxes H x 5 1 4 W x 1 5 8 D mm x 133 mm x 41 mm with strobe 4 3 8 111 mm x 5 3 4 x 0.060 Thick mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 D mm x 130 mm x 70 mm x 4 1 8 x 1 1 4 D mm x 105 mm x 32 mm H x 5 W x 1 1 2 D mm x 127 mm x 38 mm H x 6 1 16 W x 3 1 8 D mm x 154 mm x 79 mm x 6 1 8 x 3 mm x 156 mm x 76 mm x 7 mm x 178 mm x 6 7 8 x 1 1 2 deep 121 mm x 175 mm x 38 mm 4 2010 Chime Strobe Specifications Mount or Ceiling Mount Common Specifications Voltage Range Rate and Synchronized NAC Loading Temperature and Humidity Output Characteristics see Note 2 Output Ratings per UL 464 Reverberant test 10 ft 3 m dBA 24 DC see Note 1 below Hz with up to 35 synchronized strobes maximum per NAC to 122 F 0 to 50 C 10 to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per for in out wiring is adjustable from 750 Hz to 1300 Hz factory sett

Related Files