sIMPLEX 4906-9201, 4906-9202, 4906-9203, 4906-9204 TrueAlert Addressable, Multi-Candela Visible Only (V O) Appliances (Strobes), Ceiling Mount (G)

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances Multi Candela Visible Only V O Appliances TrueNAC Voltage Drop Diagnostics Individually addressed and controlled multi candela visible only notification appliances provide High intensity multi candela xenon strobe with intensity from a Simplex 4100U fire alarm panel with TrueAlert Addressable Power TPS or jumper selected as 15 30 75 or 110 cd Synchronized 1 Hz strobe flash rate Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring Backwards compatibility with fixed candela TrueAlert strobes on same Signaling Line Circuit allowing convenient expansion and replacement Compatibility with ADA requirements refer to installation information on page 4 UL listed to Standard 1971 TrueAlert Addressable Host Controls 4100U TrueAlert Addressable Power Supply TPS in the control panel or in a remote cabinet TrueAlert Addressable Controller 4009T interface multi candela appliances and 4100U fire control panels with TPS TrueNAC voltage diagnostics provide Individual appliance voltage drop analysis using intensity selection measured appliance and SLC output voltage and current Device Reports that detail type candela rating and of addressable appliances on the SLC also with TrueAlert Addressable Controller to 4100U using RUI communications Status Reports that list the diagnostic results per on the SLC see details on page 2 Requires 4100U Software Revision 12.04 or higher and TPS version indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe is also to confirm operation design features Rugged high impact flame retardant thermoplastic are available in red or white for flush or wall or ceiling mount Rear of housing does not extend into box and easily to standard electrical boxes Access to wall mount in out wiring terminals AWG to 12 AWG from front of housing assists inspection and testing Mounting options include electrical box adapters covers to convert color and red wire guards and Ceiling Mount Addressable V Os TrueAlert Addressable Multi Candela Strobes are addressed and individually controlled with supervision and control supplied from a TrueAlert SLC Additional Features When controlled from a 4100U control panel with TPS additional features available such as software selection of strobe intensity reports of actual appliance intensity selection see reports on page 2 TrueNAC voltage drop and additional setup and test diagnostics detailed on page 2 Intensity Selection Selectable at Appliance or Remotely Selected installation a plug at the back of the housing after installation is inserted to select strobe as 15 30 75 or 110 cd or FACP FACP is the default setting and allows a 4100U control panel TPS to program the output intensity Selection Advantages When intensity is in software from a 4100U fire alarm panel it can easily changed if renovations or other usage conditions revised and intensity selection errors at installation effectively eliminated See page 3 for wire guard listings This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 235 for allowable values and or conditions concerning presented in this document It is subject to re examination revision and possible Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster TrueAlert addressable notification is protected under U S Patent Nos 6,313,744 6,693,532 7,006,003 and 7,091,847 TrueNAC diagnostics are protected U S patent No 7,333,010 3 2008 Strobe Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Addressable Advantage TrueAlert Addressable Operation provides separate and visible appliance control functions using a two wire circuit that also confirms connection to the notification appliance electronic circuit This increases circuit supervision integrity by supervision beyond the appliance wiring for Reducing Installation and Time Separate controls carried on the same SLC can significantly reduce installation time and for both retrofit and new construction When B Style 4 wiring is used wiring can be T tapped savings in distance wire junction boxes and installation efficiency In addition TrueNAC further improve installation efficiency by individual appliance wiring connections Product Reference horn strobe speaker strobe Lens Strobes Mass Notification Isolator Addressable Horn Addressable Controller 4009T Fire Alarm Panels Sheet TrueAlert Device and Device Status Reports TrueAlert Addressable Diagnostics Type and Intensity Check The TrueAlert Host Control is programmed with address device type and intensity selection An incorrect replacement or substitution will produce a specific trouble allowing easy correction Communications Indicator The host control can selected to pulse each appliance LED when it receives supervision poll This feature can be left on continuously activated for system testing Mode Appliance Magnet Testing In this test the local magnet test activates the appliance LED to sequentially to indicate the appliance address and to the appliance strobe intensity selection non silent mode Appliance Magnet When this test mode is selected at the host control the address and intensity selection is indicated the will flash once to indicate proper operation TrueNAC Diagnostic Operation Appliance Performance Analysis With on the SLC activated each appliance measures terminal voltage and reports it to the 4100U TPS where address and appliance type is stored in memory The TPS measures its output voltage and current and iteratively analyzes all of this information against appliance power requirements to determine impedance to each appliance TrueNAC then analyze each appliance wiring for performance under worst case conditions identifies problems by appliance address Device Reports detail type candela rating location per appliance first sample below Fixed appliances will also report but are not compatible TrueNAC voltage drop diagnostics Status Reports detail the diagnostic results as in the second report example below 1 WED 2 Jan 08 Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 Port 6 TrueNAC Status Report AT ADDRESS 3 LABEL ID Label up to 40 characters Hall South End 2 3 CURRENT A CASE CURRENT A CASE VOLTAGE ABOVE BELOW THRESHOLD V HAS NOT PASSED UNLESS ALL DEVICES ARE MARKED AS PASSED RESULT 1 WED 2 Jan 08 3 2

Related Files