sIMPLEX 4906-9227, 4906-9228, 4906-9229, 4906-9230 TrueAlert Addressable, Multi-Candela Audible Visible (A V) Appliances, Ceiling Mount (G)

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances Multi Candela Audible Visible A V Appliances TrueNAC Voltage Drop Diagnostics Individually addressed and controlled multi candela audible visible notification appliances provide High intensity multi candela xenon strobe with intensity from a Simplex 4100U fire alarm panel with TrueAlert Addressable Power Supply or jumper selected as 15 30 75 or 110 cd Synchronized 1 Hz strobe flash rate Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring Backwards compatibility with fixed candela TrueAlert strobes on the same Signaling Line Circuit allowing convenient expansion and replacement Compatibility with ADA requirements refer to installation information on page 4 Strobe operation is UL listed to Standard 1971 operation is UL listed to Standard 464 TrueAlert Addressable Host Controls 4100U TrueAlert Addressable Power Supply TPS in the control panel or in a remote cabinet TrueAlert Addressable Controller 4009T interface panel multi candela appliances and 4100U fire alarm panels with TPS TrueNAC voltage drop provide Individual appliance voltage drop analysis using intensity selection measured appliance voltage SLC output voltage and current Device Reports that detail type candela rating and of addressable appliances on the SLC also with TrueAlert Addressable Controller to 4100U using RUI communications Status Reports that list the diagnostic results per on the SLC see details on page 2 Requires 4100U Software Revision 12.04 or higher and TPS version indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe and the is also selectable to confirm operation design features Rugged high impact flame retardant thermoplastic are available in red or white for flush or wall or ceiling mount Rear of housing does not extend into box and easily to standard electrical boxes Access to wall mount in out wiring terminals AWG to 12 AWG from front of housing assists inspection and testing Mounting options include electrical box adapters covers to convert color and red wire guards and Ceiling Mount Addressable A Vs Continued notification appliance horn Low current electronic horn with harmonically rich sound for either coded or steady operation Horns sound as Temporal or March Time pattern 60 or BPM or on continuously controlled separately visible appliances on the same two wire circuit Output is or 5 dBA difference 4100U Addressable Power Supply selects per device Addressable Controller selects per SLC Addressable Multi Candela A Vs are addressed and individually controlled with supervision and control supplied from a TrueAlert SLC Additional Features When controlled from a 4100U control panel with TPS additional features available such as software selection of strobe intensity reports of actual appliance intensity selection see reports on page 2 TrueNAC voltage drop and additional setup and test diagnostics detailed on page 2 See page 3 for wire guard listings This product has been approved by the California State Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7125 0026 239 for allowable values and or conditions concerning presented in this document It is subject to re examination revision and possible Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster TrueAlert addressable notification is protected under U S Patent Nos 6,313,744 6,693,532 7,006,003 and 7,091,847 TrueNAC diagnostics are protected U S patent No 7,333,010 3 2008 Strobe Intensity Selection at Appliance or Remotely Selected During a plug at the back of the housing visible after is inserted to select strobe output as 15 30 75 110 cd or FACP Selecting FACP allows a 4100U panel with TPS to program the output intensity Selection Advantages When intensity is selected in from a 4100U fire alarm panel it can be easily if renovations or other usage conditions are revised intensity selection errors at installation are effectively Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA Addressable Advantage Addressable Operation provides separate audible visible appliance control functions using a single circuit that also confirms connection to the notification appliance electronic circuit This increases circuit supervision integrity by providing beyond the appliance wiring connections for Reducing Installation and Testing Time controls carried on the same two wire SLC can reduce installation time and expense for both and new construction When Class B Style 4 wiring used wiring can be T tapped allowing even more savings distance wire junction boxes and overall installation The extensive diagnostics features available improved installation efficiency TrueAlert Device and Device Status Reports Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 Port 6 TrueNAC Status Report AT ADDRESS 3 LABEL ID Label up to 40 characters Hall South End 2 3 CURRENT A CASE CURRENT A CASE VOLTAGE ABOVE BELOW THRESHOLD V HAS NOT PASSED UNLESS ALL DEVICES ARE MARKED AS PASSED Addressable Product Reference Sheet Product TrueAlert Addressable Horn strobe Amber Lens Strobes Mass Notification speaker strobe Isolator TrueAlert Addressable Controller 4009T Addressable Diagnostics Type and Intensity Check The TrueAlert Host Control is programmed with address device type and intensity selection An incorrect replacement or substitution will produce a specific trouble allowing easy correction Communications Indicator The host control can be to pulse each appliance LED when it receives a poll This feature can be left on continuously activated for system testing Mode Appliance Magnet Testing In this test mode local magnet test activates the appliance LED to pulse to indicate the appliance address and to the appliance strobe intensity selection non silent mode Appliance Magnet Test this test mode is selected at the host control after the and intensity selection is indicated the strobe will once and the horn will briefly sound TrueNAC Diagnostic Operation Appliance Performance Analysis With on the SLC activated each measures its terminal and reports it to the 4100U TPS where the address appliance type is stored in memory The 4100U TPS its output voltage and current and then iteratively all of this information against known appliance requirements to determine equivalent impedance to appliance TrueNAC diagnostics then analyze each wiring connection for performance under worst conditions and identifies problems by appliance TrueAlert Device Reports detail type candela and location per appliance first sample below

Related Files