Simplex 4906-9251, 4906-9253, 4906-9254, 4906-9255, 4906-9256, 4906-9257 TrueAlert Addressable, Multi-Candela Speaker Visible (S V) Appliances (G)

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved NYC Acceptance Addressable Notification Appliances Multi Candela Speaker Visible Appliances Individually addressed and controlled S V speaker visible notification provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 or 110 cd Advanced addressable notification controlled by IDNAC from Simplex 4100ES fire alarm control panels with power supplies and 4009 IDNAC Repeaters regulated 29 VRMS allowing strobes to with lower current even under battery backup Wiring supervision to each strobe allowing connections for Class B circuits to wiring Class A circuits require in out TrueAlert Device Reports at the control panel appliance point ID custom label type and setting see sample on page 2 Magnet test diagnostics to assist checkout and testing appliances and wiring Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 UL listed to Standard 1971 and ULC S526 indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision diagnostic mode the magnet test pulses the LED to appliance address AND pulses to indicate the selection a brief output of the strobe is also to confirm operation design features Rugged high impact flame retardant thermoplastic are available for wall or ceiling mount Wall mount housings are available in red or white Wall mount options include electrical box adapters covers to convert color and red wire guards Ceiling mount housing is white notification appliance speaker High quality voice and tone reproduction with taps for 1 2 1 or 2 W at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC NACs and are wired separately from UL listed to Standard 1480 and ULC S541 See page 2 for additional listing details and wire guard listings This product has been by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 7320 0026 322 for allowable values conditions concerning material presented in this document Accepted for use City New York Department of Buildings MEA35 93E Additional listings may be applicable your local Simplex product supplier for the latest status Listings and approvals Simplex Time Recorder Co are the property of Tyco Fire Protection Products and Ceiling Mount S Vs with Addressable Strobes Multi Candela TrueAlert S Vs with speaker and strobe provide convenient installation to electrical boxes with extensions The strobe is addressed and individually controlled with supervision and control supplied from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 are wired separately Application Reference selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm and Signaling Code 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the guidelines of the Americans with Disabilities ADA SLC Operation Advantage S V Appliances with Addressable on IDNAC SLCs provide visible notification a single two wire circuit that also confirms to the individual notification appliance circuit This operation increases circuit integrity by providing supervision that beyond the appliance wiring connections 5 2013 IDNAC SLC Operation Advantage Cont current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VRMS voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up to to 3 times farther than with conventional notification or for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits all installation and maintenance savings with high that appliances that operate during normal system will operate during worst case alarm conditions Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction can significantly reduced When Class B wiring is used can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected Product Selection Addressable S Vs TrueAlert Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate short wiring from functioning wiring Refer to data S4905 0001 for additional information Addressable Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll When controller is selected for diagnostic mode the appliance test feature provides a response at the individual being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance address Appliance Testing In this test mode after address is indicated by pulsing the appliance LED the will briefly flash to indicate proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Housing Color Mounting Dimensions ULC White FIRE Red FIRE Red FIRE Blank Red ALERT Red FIRE Mount S V Adapters Replacement Covers Wire Guard Ceiling Mount Tile Bridge 191 mm diameter speaker 13 mm deep lens extends 67 mm above housing into box 2 70 mm H x 5 W x 2 D mm x 127 mm x 67 mm with Strobe selectable 15 30 75 or 110 Surface Mount Red Adapter Skirt Required when mounting to surface Surface Mount White Adapter Skirt Adapter Plate red required to mount S V on 2975 9145 mounting box Mounting Box red for surface or flush mount requires adapter plate 4905 9903 electrical box 4 square 1 with 1 deep extension for retrofit box may be available for retrofit applications Red Wall Mount S V Replacement Cover with white lettering White Wall Mount S V Replacement Cover with red lettering Red Wire Guard for Wall Mount S V with mounting plate compatible with surface semi flush boxes UL listed by Space Age Electronics Inc Tile Bridge for Ceiling Mount S Vs H x 5 W x 3 3 D mm x 137 mm x 81 mm with S V 5 149 mm 5 H x 5 W x 0.060 Thick mm x 146 mm x 1.5 mm H x 5 W x 2 D mm x 130 mm x 70 mm H x 5 W x 1 D mm x 127 mm x 35 mm H x 6 1 W x 3 D mm x 154 mm x 79 mm diagram on page 3 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report ID LABEL Label up to 40 characters

Related Files