Simplex 49AO Series TrueAlert ES Addressable Notification Appliances Audible Notification Appliances, Electronic Horns, Model Series 49AO (G)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-49ao-series-truealert-es-addressable-notification-appliances-audible-notification-appliances-electronic-horns-model-series-49ao-g-2987413506.pdf |
---|---|
Type | |
Size | 772.61 KB |
Downloads |
Text Preview
ULC CSFM Listed Approved Addressable Notification Appliances Notification Appliances Horns Model Series 49AO addressed and controlled low power ES A O audible only electronic horns Advanced addressable notification controlled by SLCs from Simplex 4100ES fire alarm panels with EPS EPS power supplies and IDNAC Repeaters providing regulated VRMS allowing strobes on the same SLC to with lower current even under battery backup Wiring supervision to each appliance allows connections for Class B circuits to wiring Class A circuits require in out Horns are controlled separately from visible on the same SLC with control panel of operation as Temporal Code 3 March selectable as 20 60 or 120 bpm Continuous Temporal Code 4 Output of or 6 dBA difference at the appliance or from the controller with mode selected at the appliance Unobtrusive magnet test diagnostics are available to checkout and testing of appliances and wiring Electrical test point access without removing cover Compatible with legacy TrueAlert addressable for upgrade and replacement see page 4 Listed to UL Standard 464 and ULC Standard S525 Indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the magnet pulses the LED to indicate appliance address and selectable to also briefly sound the horn to confirm design features include Rugged high impact flame retardant thermoplastic in red with white letters or white with red available with FIRE FEU FIRE FEU or blank Separate covers are available to change application on site or for replacement covers can be easily without disturbing the connected housing avoiding trouble conditions A separate mounting plate allows wiring to be before appliance is mounted use with gang double gang or 4 inch square box flush surface mount wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes ES Addressable Horns are Available in Red with Lettering and White with Red Lettering ES addressable horns are individually audible notification appliances that receive supervision and control signals from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 ES Operation Advantage ES addressable appliances on IDNAC provide separate audible and visible notification a single two wire circuit that also confirms connection the individual notification appliance electronic circuit operation increases circuit supervision integrity by supervision that extends beyond the appliance connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VRMS voltage is maintained even during battery standby strobes on the same SLC to operate at higher with lower current and ensuring a consistent current and voltage drop margin under both primary power and battery standby Efficiencies include wiring up to 2 to 3 times farther than with conventional or support for more appliances per IDNAC or use of smaller gauge wiring or combinations of benefits all providing installation and maintenance with high assurance that appliances that operate normal system testing will operate during worst case conditions These products have been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7135 0026 0372 allowable values and or conditions concerning material presented in this document listings may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 5 2013 TrueAlert ES Operation Advantage Cont Installation and Testing Time With controls on the same two wire SLC installation and expense for both retrofit and new construction be significantly reduced When Class B wiring is wiring can be tapped allowing more savings in wire conduit size and utilization and overall efficiency Use of the magnet test feature installation efficiency TrueAlert device reports identify information about each connected ES Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll the controller is selected for diagnostic mode the magnet test feature provides a response at the appliance being tested TrueAlert ES Diagnostics Continued Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode after address is indicated by pulsing the appliance LED the will briefly sound to indicate proper operation Instrument Two TSIT The 2nd of the Simplex TrueStart Test Instrument adds of IDNAC SLC wiring and TrueAlert ES to its ability to test IDCs NACs and IDNet before connection to the control panel contact your local Simplex representative for information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring Refer to sheet S4905 0001 for additional information Product Selection ES Addressable Electronic Horns Color Mounting Plate Required when ordering model 49AO APPLW cover and mounting plate separately ES addressable AO only horn appliance cover and matching plate Covers Required when ordering model 49AO APPLW plate select color to match cover with Cover H x 5 W x 1 D mm x 127 mm x 38 mm Note BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and mounting plates are assembled in the USA Adapters Description Mount Adapter Skirt Red White Red Adapter Plate for mounting to Simplex 2975 9145 typically for retrofit mount vertical or horizontal Red Mounting Box requires 4905 9931 Adapter Plate H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with horn 3 79 mm 5 x 5 x 0.060 Thick 211 mm x 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 mm x 70 mm 5 2013 TrueAlert Device Reports Reference Port 5 TrueAlert Device Report LABEL ID Label up to 40 characters Room 5 Room Room 7 1 MON 20 May 13 Installation Reference is compatible with single gang gang and 4 102 mm square boxes 38 mm deep supplied separately terminals and clips assembly cover bladed screwdriver to latch on left side indicator test point access holes bottom configuration switch accessible rear of housing Holes gang 2 gang 4 square 4 test location of housing setting DIP switch from rear of housing Adapter Plate and Su