Simplex 49AV Series TrueAlert ES Addressable Notification Appliances; Audible Visible Notification Appliances, Wall Mount; Multi-Candela Horn Strobe, Model Series 49AV (G)
File Preview
Click below to download for free
Click below to download for free
File Data
Text Preview
ULC CSFM Listed Approved Addressable Notification Appliances Notification Appliances Wall Mount Horn Strobe Model Series 49AV addressed and controlled multi candela ES A V audible visible notification provide Multi candela xenon strobe with synchronized 1 Hz flash and with intensity programmable from the control or jumper selected as 15 30 75 110 135 or 185 cd Advanced addressable notification controlled by IDNAC from Simplex 4100ES fire alarm control panels EPS EPS power supplies and 4009 IDNAC providing regulated 29 VRMS allowing to operate with lower current even under battery Wiring supervision to each appliance allowing connections for Class B circuits to simplify Class A circuits require in out wiring TrueAlert Device Reports at the control panel detailing point ID custom label type and candela see sample on page 3 Magnet test diagnostics to assist checkout and testing of and wiring Electrical test point access without removing cover Compatibility with ADA requirements refer to installation information on page 3 Compatibility with legacy TrueAlert addressable for upgrade and replacement see page 4 Strobe operation is listed to UL Standard 1971 and ULC S526 Horn operation is listed to UL Standard and ULC Standard S525 Indicator and magnet test feature Appliance LED can be selected to display each polling to indicate appliance supervision When the controller is in diagnostic mode the magnet pulses the LED to indicate appliance address and can set to also briefly flash the strobe and sound the horn design features include Rugged high impact flame retardant thermoplastic in red with white letters or white with red with clear lens available with FIRE ALERT FIRE FEU or blank lettering Separate covers are available to change application type or for replacement A separate mounting plate allows wiring to be before appliance is mounted use with single double gang or 4 inch square box flush or mount Covers can be easily removed without disturbing the housing and avoiding trouble conditions wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover mounted electrical boxes and to adapt to 2975 9145 boxes ES Addressable A Vs are Available in Red with Lettering and White with Red Lettering Continued notification appliance horn Harmonically rich output sound for either coded or operation Horns sound as Temporal Code 3 March Time pattern or Temporal Code 4 controlled separately visible appliances on the same two wire circuit Selectable March Time rates of 20 60 or 120 beats per Output is or 5 dBA difference at the appliance or from the controller with mode selected at the appliance TrueAlert ES addressable A Vs are individually visible notification appliances that receive supervision and control signals from a Simplex alarm control panel providing IDNAC Signaling Line SLCs See compatibility list on page 4 Application Reference Proper selection of visible notification is dependent on location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI the appropriate model building code BOCA or SBCCI and the application guidelines of the with Disabilities Act ADA These products have been approved by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products 5 2013 TrueAlert ES Operation Advantage ES addressable appliances on IDNAC SLCs separate visible and audible notification using a single circuit that also confirms connection to the individual appliance electronic circuit This operation circuit supervision integrity by providing supervision extends beyond the appliance wiring connections current allows efficient IDNAC SLC With IDNAC SLCs a constant 29 VRMS voltage is maintained even during battery standby strobes to operate at higher voltage with lower and ensuring a consistent current draw and voltage margin under both primary power and secondary standby Efficiencies include wiring distances up to to 3 times farther than with conventional notification or for more appliances per IDNAC SLC or use of gauge wiring or combinations of these benefits all installation and maintenance savings with high that appliances that operate during normal system will operate during worst case alarm conditions Reducing Installation and Testing Time With separate on the same two wire SLC installation time and for both retrofit and new construction can be reduced When Class B wiring is used wiring be tapped allowing more savings in distance wire size and utilization and overall installation Use of the magnet test feature improves efficiency TrueAlert device reports conveniently information about each connected appliance Product Selection TrueAlert ES Diagnostics Features Controllers can be selected to pulse each LED when it receives a supervision poll the controller is selected for diagnostic mode the magnet test feature provides a response at the appliance being tested Appliance Magnet Test In this test mode in to the magnet test the appliance LED pulses to conveniently indicate the appliance Appliance Testing In this test mode after address is indicated by pulsing the appliance LED the will briefly flash and the horn will briefly sound to proper operation Instrument Two TSIT The 2nd generation the Simplex TrueStart Test Instrument adds testing of SLC wiring and TrueAlert ES appliances to its to test IDCs NACs and IDNet communications connection to the control panel Please contact your Simplex representative for additional information Addressable Wiring Isolator Model 4905 9929 is available for remote on TrueAlert addressable circuits to isolate circuited wiring from functioning wiring Refer to sheet S4905 0001 for additional information ES Wall Mount Addressable Audible Visible Appliances ES addressable A V appliances include cover and matching mounting plate except as noted with Cover 5 H x 5 W x 1 D 130 mm x 127 mm x 38 mm Color Color Color Mounting Plate cover and mounting plate separately Color Covers Required when ordering model 49AV APPLW Plate is required when ordering model 49AV APPLW Note BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and mounting plates are assembled in the USA Adapters Description Red Surface Mount Adapter Skirt White Red Adapter Plate for mounting to Simplex 2975 9145 Box Red Mounting Box requires 4905 9931 Adapter Plate for retrofit mount vertical or horizontal H x 5 W x 1 D 136 mm x 133 mm x 41 mm depth with strobe 4 111 mm 5 x 5 x 0.060 Thick 211 mm x 146 mm x 1.5 mm x 5 x 2