Simplex 5120-9141 25 Volt Line Conversion Board

File Preview
File Preview
Click below to download for free

File Data

Name simplex-5120-9141-25-volt-line-conversion-board-0592846371.pdf
Type PDF
Size 1.03 MB
Downloads

Text Preview

COMMUNICATIONS Options and Accessories 25 Volt Line Conversion Board Requires One Slot in Standard 5110 5120 Directly Compatible with Existing 25 Volt Twelve 25 Volt Line Outputs per Board Directly Compatible with 5130 9140 Boards in 5110 5120 Systems Provides Two Wire Call In Capabilities Precision Wound High Efficiency Rack 5120 9141 25 Volt Conversion board provides the Series Communications Systems with the ability drive speakers with 25 volt transformers This allows the of existing speakers in retrofit applications while still the advanced features of the 5100 systems new board does not change the 5100 system unique 1 watt chip amplifier design The 5100 system architecture which provides unsurpassed redundancy an amplifier for each speaker is uncompromised This allows paging operation even when a speaker circuit shorted Other intercom systems which incorporate one paging amplifier can lose paging capabilities if a single circuit is shorted 5120 9141 also provides the ability for Wire This allows a 25 volt line speaker and call switch to over a single twisted shielded pair of wire The 5120 can operate on two individually twisted pairs as well the room speaker connected to one pair and its call switch connected to the other Since both these wiring schemes were commonly used most retrofit can be easily supported Conversion board offers both standard telephone punchblocks and screw terminal blocks 5120 9923 for existing wire in retrofit applications The screw blocks should be used whenever stranded wire or solid larger than 20 AWG is being terminated Conversion Board accommodates 12 speaker and requires one slot position in the 5110 5120 card The 5120 9141 does not require power nor occupy an in the 5100 system of Outputs connections Requirements Power Response 25 pair Amphenol Watt 25 VRMS Hz 0dB may result in specification or feature change without notice 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 8 25 volt Transformer Talkback Switch Commercial Grade 8 25 volt Transformer Talkback Switch Commercial Grade Type Twisted Pair Type Twisted Pair 5120 9141 25 Volt Conversion Board and Call Switch Punch Block 5120 9141 25 Volt Conversion Board and Call Switch Punch Block 1 2 Switch Connections using Twisted Pair Wiring Method to a Multiple Tap and 8 Ohm Secondary 25 Volt Transformer Switch Connections using Wiring Method to a Multiple Tap and 8 Ohm Secondary 25 Volt Transformer 1 and 2 depict wiring to existing 25 volt speakers whose transformers have a multiple tap primary winding connecting 25 volt amplifier outputs These transformers usually have multiple leads of different colors for each tap Each 5120 9141 output can drive up to a 1 watt load 1 shows wiring connections when provided with two individually twisted pairs from each location 2 shows typical connections when provided with one twisted shielded pair from each location 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 8 25 volt Transformer Talkback Taps on Primary of Can use up to Tap Maximum PAIR OPEN SWITCH 5120 9141 25 Volt Conversion Board and Call Switch Punch Block 3 Switch Connections using Twisted Shielded Drain Wire and Point Wire to a Multiple Tap Primary 8 Ohm Secondary 25 Volt Transformer cable pairs conductors must be free of shorts opens and grounds shielding must be isolated from electrical and building grounds Use wire sleeve insulation on drain and tape back foil to isolate runs must be point to point and continuous Splices or distribution must also be free of shorts opens grounds Each home run must not exceed 500 feet If it does exceed 500 feet new cable must be pulled accordance with the new construction wiring specifications 22 AWG unshielded twisted pair telephone stranded wire may be found in retrofit installations Use the 5120 9923 screw terminal block in such Observe polarity on call switch wires at punch block Ensure that shield drain wire is used for negative feed on call switch 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 System Before Simplex Installation Each Wire and Cut Here SYSTEM Cables Plug Into Existing Bank Modules After Simplex Installation RACK Building Communicati 00 PZS 140 Four Zone to accommodate paging Corridors Common Areas and the Building Classrooms and Speaker Zones Block Cables Connections Administrative LCD Displays etc Terminal Cabinet Screw Terminal Blocks Terminal Block Back Board cut wires to Terminal Blocks Classrooms Multiple Zones Lug inside Cabinet Building Communicati Dedicated and Isolated Amp Circuit Breaker 25 70 Volt Multiple Speaker Zones and Terminate on of Booster Amplifier s to an Approved Building Grounding System per the National Electrical Code 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 Card Layout with 24 Point System in 5110 or 5120 System Rack 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 Card Layout with 48 Point System in 5110 9110 Rack 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 5110 System Layout using 5120 9141 25 volt Boards in 5110 9110 Expansion Cabinet 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 the Simplex logo and TrueCom are registered trademarks of Simplex Time Recorder Co in the U S and or other countries 1999 Simplex Time Recorder Co All rights reserved S5100 0014 2 5 99 Massachusetts 01441 0001 USA www simplexnet com specifications and other information shown were current as of printing and are subject to change without notice

Related Files