Simplex 601I-ULC Series 600 Ionization Smoke Detectors for two-wire bases (D)

File Preview
File Preview
Click below to download for free

Text Preview

Listed 600 Ionization Smoke Detector details Superior performance and reliability Attractive new design Designed for fast and easy installation Unique position for commissioning and service seamlessly with a wide range of panels Compatible with Tyco 600 Series for easy upgrade Low operating current up to 32 detectors per zone Optional remote alarm indicating LED Low profile discrete and unobtrusive Designed for EMI compatibility UL listed to Standard 268 chamber enclosure Concentric baffle design enhances smoke capture by air flow to the smoke chamber DETECTORS CONTAIN A SMALL AMOUNT RADIOACTIVE MATERIAL Americium 241 ARE SAFE UNDER THE PRESCRIBED OF USE BUT MUST NOT BE BY UNAUTHORIZED PERSONS AND TRANSPORT OF DETECTORS BE ARRANGED IN ACCORDANCE WITH SAFETY REGULATIONS Detection Ionization chamber detectors due to air within the chamber being ionized by a small americium source thus enabling a current to between two electrodes This current will reduce by measurable level when combustion aerosols enter the and bind to the ionized air Detectors based on ionization chamber principle respond best to the smoke combustion aerosols i e those produced the faster burning type of fire 600 Smoke Detectors Series 600 Ionization Smoke Detectors Two Wire Bases Ionization Smoke Detector Mounted 5B Base with 6A 5B UL Adapter 600 Detector Features the chamber is a perforated electrode known as the This electrode will under clean air conditions a certain potential relative to the outer cover This is due to the radioactive emissions ionizing the and is relatively stable smoke aerosols are introduced into the chamber they the ionized air such that an imbalance occurs the potential of the collector The magnitude of potential is used to indicate the smoke density The that flows across the chamber is very small and device used to sense the potential of the collector therefore be of very high impedance ensure high stability and resistance to corrosion all parts of the chamber are of stainless steel and the insulators are of PTFE Reference Locations see table on page 4 Locations be determined only after careful consideration of physical layout and contents of the area to be Refer to NFPA 72 the National Fire Alarm On smooth ceilings smoke detector spacing of 30ft may be used as a guide Refer to page 2 for additional listing information This product was not ULC or CSFM or approved by FM or MEA NYC as of document revision date Additional listings be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Products 3 2009 Product Selection Bases Smoke Detector Sensitivity to 0.907 ft with 5B base 5 127 mm diameter Base with connections for Alarm LED Indicator and LED connections are screw for input output wiring 18 to AWG 1 mm2 to 1.5 mm2 Reference listed under Thorn Security LTD Accessories Base Adapter 152 mm Protective Cage Shorting Adapter Detector Status LED Indicators Indication approximately every 10 seconds On Dimensions and Reference Information the 5B surface area protective cage for Series 600 using the 5B base tool shorts out base to enable cable resistance to be carried out Reference listed under Thorn Security LTD listed not applicable service tool Detector Cage 3 2009 Mounting Information Specifications Current Current Velocity Range Temperature Range Temperature Range Range base base with base adapter to 33 VDC from fire alarm control panel IDC 24 VDC to 68 mA maximum exact current is determined by alarm current of connected IDC ft sec 5 m sec only up to 2000 ft 1500 m F to 176 F 25 C to 80 C F to 100 F 0 C to 38 C to 95 non condensing 019 Dia x 2 1 8 H 127 mm x 55 mm Dia x 2 9 16 H 152 mm x 66 mm 3 2009 Application of 600 Series Detectors table below is for guidelines only specific situations are likely to require variations on the suggested detector types Real may require detector combinations to cover all likely risks Very clean dry moderately regulated smoky and or Example room light hospitals bay diesel etc ferry deck pen laundry room test Loading electric cable clothes furnishings cardboard foams bedding shavings liquids solvents gasses general waste fodder structures fuels chemicals materials contents Risk pyrolosis fumes arcs source electrical difficult locate toxic likelihood of back fire rapid of dense high fumes explosion and flame fairly slow but temperatures established of fire risk may as can the type fire may require a of detection is a registered trademark of Tyco International Services GmbH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 3 2009

Related Files