Simplex 601P-UL, 601P-UL-L Series 600 Optical Smoke Detectors for two-wire bases (D)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-601p-ul-601p-ul-l-series-600-optical-smoke-detectors-for-two-wire-bases-d-3580124976.pdf |
---|---|
Type | |
Size | 736.59 KB |
Downloads |
Text Preview
Listed 600 Optical Smoke Detector details Superior performance and reliability Attractive new design Designed for fast and easy installation Unique position for commissioning and service seamlessly with a wide range of panels Compatible with Tyco 600 Series for easy upgrade Low operating current up to 32 detectors per zone Optional remote alarm indicating LED Low profile discrete and unobtrusive Designed for EMI compatibility UL listed to Standard 268 available in two sensitivity settings 601P UL Standard Sensitivity nominal 2.11 to 3.8 ft 601P UL L Special Application Sensitivity nominal to 3.8 ft obscuration chamber enclosure Concentric baffle design enhances smoke capture by air flow to the smoke chamber Detection The optical detector uses a unique system Unlike most other optical scatter the optical design does not use vertical chevrons exclude ambient light but uses concentric baffles This gives a better signal to noise ratio type of detector is very effective in detecting very levels of visible smoke particulates often at levels they are not visible to the naked eye Invisible aerosol products cannot however be detected current optical smoke detectors as these aerosols do scatter or obscure light This means that optical favor the type of fire that we have described as burning this is true some smoldering materials such as will produce a predominantly black smoke which less scattering properties than white smoke and will detected later than an equivalent density of white 600 Smoke Detectors Series 600 Optical Smoke Detectors Two Wire Bases Optical Smoke Detector Mounted 5B Base with 6A 5B UL Adapter 600 Detector Features optical system consists of an infrared emitter and arranged such that their optical axes cross in the volume The emitter produces a narrow beam of which is prevented from reaching the receiver by the When smoke is present in the sampling volume a of the light is scattered some of which reaches receiver For a given type of smoke the light reaching photodetector is proportional to the smoke density emitter is a GaAlAs solid state type operating in the infrared at 880 nm while the sensor is a matched photodiode These devices are held in place by the mouldings The design of the labyrinth is such the presence of small insects should not cause false Reference Locations see table on page 4 Locations be determined only after careful consideration of physical layout and contents of the area to be Refer to NFPA 72 the National Fire Alarm On smooth ceilings smoke detector spacing of ft 9.1 m may be used as a guide Selection The 601P UL standard detector is recommended for most applications a special application for reduced sensitivity is required the 601 P UL L should be Consult your local Simplex product supplier assistance in determining the proper selection Refer to page 2 for additional listing information This product was not ULC or CSFM or approved by FM or MEA NYC as of document revision date Additional listings be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Products 3 2009 Product Selection to 3.8 ft to 3.8 ft Bases Base with connections Remote Alarm LED Accessories 152 mm Base Adapter Protective Cage Shorting Adapter Detector Status LED Indicators Indication approximately every 10 seconds On Dimensions and Reference Information Smoke Detector Compatible with 5B base 5 127 mm diameter and LED connections are screw for input output wiring 18 to AWG 1 mm2 to 1.5 mm2 Reference listed under Thorn Security LTD the 5B surface area protective cage for Series 600 using the 5B base tool shorts out base to enable cable resistance to be carried out Reference listed under Thorn Security LTD listed not applicable service tool only Detector Cage 3 2009 Mounting Information Specifications Current Current Temperature Range Temperature Range Range base base with base adapter to 33 VDC from fire alarm control panel IDC 10.5 VDC 24 VDC 33 VDC to 68 mA maximum exact current is determined by alarm current of connected IDC F to 176 F 25 C to 80 C F to 100 F 0 C to 38 C to 95 non condensing 019 Dia x 2 1 8 H 127 mm x 55 mm Dia x 2 9 16 H 152 mm x 66 mm 3 2009 Application of 600 Series Detectors table below is for guidelines only specific situations are likely to require variations on the suggested detector types Real may require detector combinations to cover all likely risks Very clean dry moderately regulated smoky and or Example room light hospitals bay diesel etc ferry deck pen laundry room test Loading electric cable clothes furnishings cardboard foams bedding shavings liquids solvents gasses general waste fodder structures fuels chemicals materials contents Risk pyrolosis fumes arcs source electrical difficult locate toxic likelihood of back fire rapid of dense high fumes explosion and flame fairly slow but temperatures established of fire risk may as can the type fire may require a of detection is a registered trademark of Tyco International Services GmbH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 3 2009