Name | simplex-addressable-devices-multiple-series-idnet-and-mapnet-ii-addressable-devices-device-communications-compatibility-chart-b-c-8240736951.pdf |
---|---|
Type | |
Size | 630.76 KB |
Downloads |
Text Preview
Compatible with 4008 4010 4010ES 4100U 4100ES IDNet Communications MAPNET II Communications and MAPNET II Addressable Devices Communications Compatibility Chart B IDC ZAM A IDC ZAM Sensor Housing without relay Sensor Housing with relay Sensor Housing without relay Sensor Housing with relay Base with connections for remote LED or unsupervised relay aspiration sensor housings 100 110 single inlet 200 210 are dual inlet 200 210 with Special Considerations Base rem LED relay supv relay Sensor Base Base Station Standard Station Breakglass Station Push ULC FM MEA Single Action Addressable IAMs 4090 9051 is and w o LED Addressable Controller Address Sounder Base sensor Address Standard Base Multi Sensor for above bases Multi Sensor one address for heat and TrueSense operation 4010ES 4100U only Releasing Station Push Communications Isolator mA AMZ revision 2.01 firmware LaserCOMPACT IDNet NAC Extender 4009 A requires rev 11 software or higher B A Repeater not MEA approved Message Board UL C UL Fiber Optic Transmitter MEA approved Signal IAM 4010 4010ES 4100U 4100ES IDNet provide sense II provides Class B monitoring of N O contacts IDNet 4100 and 4010ES 4100U 4100ES control RUI 4010 4100ES 4010ES and 4100U IDNet and II two consecutive addresses does not provide operation see below for dual address applications of 4098 9754 4100ES 4010ES 4100U IDNet only requires only address use with sensor bases 4098 9789 4098 9791 4098 9794 4098 9793 4098 9797 4098 9798 with IDNet or MAPNET II Releasing panels only 4100U 4100ES and 4008 IDNet 4100U 4100ES IDNet 4100U requires software 11.11.01 or higher or with 4008 IDNet requires address but consumes two unit loads 4100U 4100ES IDNet or 4100U 4100ES II Operation MAPNET II requires one unit load requires two unit loads 4100U 4100ES IDNet or MAPNET II Operation ULC ULC FM MEA in ULC MEA ULC IAM Base Release Peripheral SRP enclosure uses 2975 9227 ULC not applicable for use with SRP with Enclosure ULC FM MEA in Compatible with 4010 4010ES 4100U 4100ES IDNet Communications Only except as noted Compatible w2ith 4010ES 4100U 4100ES IDNet Communications Only Module 4 T Sense inputs 2 relays Monitor IAM two unit loads Microphone Multiplex Module internal IAM Sensor Sounder Base Power Isolator IAM with T Sense Input IAM with unsupervised input Sensor Standard Base Compatible with MAPNET II Communications Only refer to pages 2 and 6 for legacy products 9154 Monitor ZAM Style D IDC 9156 Monitor ZAM Style B IDC 9158 4 Wire Detector ZAM IDC 9160 Signal ZAM Style Z NAC Compatible with 4010 IDNet Communications or 4100U 4100ES with 4100 3106 IDNet Expansion Module 9162 Signal ZAM Style Y NAC 9164 Control Relay ZAM DPDT Contacts I O Module powered isolators non addr 9170 ULC FM MEA ULC FM MEA QuickConnect2 Sensor uses 4098 9788 multi purpose base ULC FM CSFM MEA Requires 4010ES 4100ES or 4100U with Revision 11.0 software or higher For 4100ES 4100U IDNet Isolators are not compatible with the Quad Panel Mount Isolator if Quad isolator is required use 4100 3107 IDNet Module For IDNet communications 1 address is but the available SLC address count is reduced by 2 due to supervisory current requirements Requires 4010 Revision 3.01 software higher or 4100U Revision 11.05 software or higher or 4010ES 4100ES LISTINGS NOTE Listings shown are for reference refer to individual data sheets for detailed information 5 2013 Communications Compatibility with Devices in Numerical Order without listings includes legacy devices not listed on page 1 refer to page 1 and product data sheets for additional information 4010ES IDNet IDNet 4008 IDNet MAPNET II Addressable Station double action push no Simplex logo Addressable Station double action push Addressable Station single action Addressable Station double action breakglass Addressable Station single action LOCAL Monitor ZAM Class A IDC surface mount Monitor ZAM Class A IDC flush mount Monitor ZAM Class B IDC surface mount Monitor ZAM Class B IDC flush mount 4 Wire Detector ZAM Class B IDC surface mount 4 Wire Detector ZAM Class B IDC flush mount Signal ZAM Class A NAC surface mount Signal ZAM Class A NAC flush mount Signal ZAM Class B NAC surface mount Signal ZAM Class B NAC flush mount Control Relay ZAM DPDT Contacts surface mount Control Relay ZAM DPDT Contacts flush mount Line Powered Isolator non addressable surface mount Line Powered Isolator non addressable flush mount Individual Addressable Module IAM includes 2190 9172A 2 Point I O Module 4009 IDNet NAC Extender 4009A 120 VAC input 4009 IDNet NAC Extender 4009A 240 VAC input TrueAlert Addressable Controller 4009T IDNet Repeater mounts in 4009A or 4009T only Supervised IAM with LED Relay IAM Suppression Release Peripheral SRP no enclosure SRP with Enclosure package IDNet Signal IAM one address Supervised IAMs encapsulated w o LED Class B IDC ZAM Class B IDNet Fiber Optic Transmitter Class A IDC ZAM Class A IDNet Fiber Optic Transmitter IDNet Communications Isolator see note next page Addressable Power Isolator Relay IAM with T Sense Input Relay IAM with unsupervised input 6 Pt Module 4 T Sense inputs 2 relays Security Monitor IAM 2 unit loads Duct Sensor for 4098 9701 Sensor Head 4 wire Duct Sensor for 9701 Sensor Head 2 wire 2120 CDT In Duct Sensor for 4098 9701 Sensor Head 4 wire In Duct Sensor for 9701 Head 2 wire 2120 CDT Duct Sensor for 4098 9701 Head 4 wire w 4 base Duct Sensor for 9701 Head 2 wire w 4 base 2120 CDT In Duct Sensor for 4098 9701 Head 4 wire w 4 base In Duct Sensor for 9701 Head 2 wire w 4 base 2120 CDT In Duct Sensor Housing without relay In Duct Sensor Housing with relay Legacy Duct Housing for 4098 9714 without relay 2120 CDT Legacy Duct Housing for 4098 9714 with relay