Simplex Addressable Loop Power Sounder Beacon Sounders Devices and Bases

File Preview
File Preview
Click below to download for free

Text Preview

UL listed Technology Addressable Visual Indicating Device VID Loop Power Sounder Beacon Sounders Devices and Bases Technology Addressable Loop Power Sounder Beacon and Compact unobtrusive and discrete design solution MX Addressable Loop powered base and wall mounted devices Listed to UL 464A for general signaling operation Low current draw due to energy efficient LED beacon Built in line isolator Ability to select multiple tones volume and flash rates Independent addressable control of the sounder and beacon No additional wiring or power supplies as the loop provides power and Locking pin prevents unauthorized removal at base Aesthetically pleasing rectangle wall mount with indoor and outdoor Indoor models semi flush or surface with a choice of shallow or deep box Loop Powered Visual Indicating Device VID Sounder Beacons and use MX technology communication for control and power units operate with Simplex 4100ES or 4010ES Fire Alarm Control FACUs through the MX Loop Card s addressable loop loop communications provide supervision of the devices Activate using the tone selection control in the MX Loop Module flash rate is selected at the sounder beacon using the MX Engineering Management Tool sounder beacons and sounders are available in ceiling and wall variants The ceiling mounted variants provide a base for fitting fire detector Alternatively a blanking cap is fitted All VID sounder and sounders have a built in two port loop short circuit isolator settings for tones volume beacon flash and status monitoring service tool 850EMT 801AP with Simplex 4100ES and 4010ES series FACUs equipped with an Loop module specifications and requirements see Technical specification or refer the installation document 579 1317 programming and configuration default address configuration is 255 Use either the 850EMT or service tool to set the address before installing the devices To set address complete the following instructions Remove the front cover to access the programming port on wall The 850EMT tool can be used to set the tone flash rate and level 1 2 Wall Sounder and Sounder Beacon VID indoor application 3 4 Wall Sounder and Sounder Beacon VID indoor application 5 6 Wall Sounder and Sounder Beacon VID outdoor application 7 8 Sounder and Sounder Beacon Base indoor application to UL 464A for general signaling operation Additional listings may be applicable contact your local product supplier for the latest status Rev 2 8 2020 Loop Power Sounder Beacon Sounders Devices and Bases selection Base Sounder Base Sounder VID Wall Sounder White Wall Sounder Red Wall Sounder Waterproof Wall Sounder Beacon VID White Wall SounderBeacon VID Red Wall Sounder Beacon VID 1 Product selection base variant 2 Product selection wall variant with 4905 5201 and 4905 5202 with 4905 5203 4905 5204 4905 5206 and 4905 5207 with 4905 5203 4905 5204 4905 5206 and 4905 5207 3 Accessories sold seperately Cap for Sounder Base Adaptor for Sounder Base Surface Back Box for Indoor Wall Sounder Red Surface Back Box for Indoor Wall Sounder White Back Box Adaptor for Indoor Wall Sounder Surface Back Box for Indoor Wall Sounder Red Surface Back Box for Indoor Wall Sounder White colour 2 Rev 2 8 2020 Loop Power Sounder Beacon Sounders Devices and Bases specification orientation outdoor mm x 45 mm temp to 70 32 to 158 4 Technical specification Beacon mm x 135 mm x 40 mm 105 mm x 153 x 97 mm to 70 to to 49 32 to 120 mm x 135 mm x 40 mm 105 mm x 153 x 97 mm to 70 to to 49 32 to 120 g 5.15 oz 154 g 5.4 oz 182 g 6.4 oz 182 g 6.4 oz 358 g 12.6 g 6.8 oz 194 g 6.8 oz 372 g 13.1 temp volument setting of selectable tones flash rate rating connection to 70 13 to 158 to 95 non condensing 21 blocks for wire size 0.5 mm2 to 2.5 mm2 20 AWG to 14 AWG Hz to 1 Hz 21 21 21 55 Hz to 1 Hz 21 21 55 5 Output Sounder output at 1m 3.28 ft dBA dBA 6 Loop loading Refer to 579 1317 for installation instructions volume volume volume volume dBA dBA dBA dBA flash rate if Hz Hz mA mA mA Refer to the loop loading calculator for these units mA mA mA mA mA mA mA mA mA mA mA mA mA volume sounder sounder beacon Base sounder sounder beacon 3 Rev 2 8 2020 Loop Power Sounder Beacon Sounders Devices and Bases 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 2 8 2020

Related Files