Simplex Audible Visible Notification Appliances, Weatherproof Ceiling Mount Multi-Candela Horn Strobe, Model Series 49AV

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC Listed FM Approved ES Addressable Notification Appliances and Visible Notification Appliances Weatherproof Ceiling Mount Multi Candela and Strobe Model Series 49AV Output is high or low 5 dBA difference selectable at the appliance or the controller with FACU mode selected at the appliance Mount Addressable Visible A V Notification Appliances individually addressed audible and visible notification appliances that power supervision and control signals from a Simplex fire alarm unit FACU providing IDNAC signaling line circuits SLCs LED Xenon tube strobe devices are interoperable on the same IDNAC addressed and controlled multi candela TrueAlert ES audible and visible notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control unit or jumper selected at appliance as 110 cd 135 cd or 185 cd Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC to allow horns to operate with current Wiring supervision to each appliance to allow T tap connections for B circuits to simplify wiring Class A circuits require in and out Self Test Mode uses an on board sensor to detect the horn output report the status to the control unit TrueAlert Device Reports at the control unit detailing appliance ID custom label type and candela setting See an example in device reports reference Magnet Test diagnostics to assist checkout and testing of the and wiring Remove the cover to access the electrical test point Compatibility with Americans with Disabilities Act ADA requirements Installation reference Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can also be set to briefly flash strobe and sound the horn design features Rugged high impact flame retardant thermoplastic housing available a variety of colors and lettering Separate covers are available for replacement or to change the type on site Covers can be easily removed without disturbing the connected avoiding trouble conditions In and out wiring terminals for 18 AWG to 12 AWG Optional red wire guards see Product selection notification appliance horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern or Temporal Code 4 controlled separately from visible on the same two wire circuit Selectable March Time rates of 20 beats per minute bpm 60 bpm 120 bpm 1 ES Addressable A V application reference selection of visible notification is dependent on occupancy local codes and correct applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the application guidelines of ADA ES operation advantage ES addressable appliances on IDNAC SLCs separate visible and audible notification using a single two circuit that also confirms connection to the individual notification electronic circuit This operation increases circuit supervision by providing supervision that extends beyond the appliance connections current usage on IDNAC SLCs IDNAC SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby may include the following Wiring distances up to three times farther than with conventional Support for more appliances for each IDNAC SLC Use of smaller gauge wiring provides installation and maintenance savings with high assurance appliances that operate during normal system testing will operate worst case alarm conditions installation and testing time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped to allow savings in distance wire conduit size and utilization as well overall installation efficiency Use of the Self Test and Magnet features improve installation efficiency TrueAlert device reports identify information about each connected appliance Rev 2 11 2019 and Visible Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn and Strobe Model Series 49AV ES diagnostics features IDNAC SLCs are in diagnostic mode the Self Test and Magnet Test features provide individual appliance testing Use the Self Test feature to appliance operation without leaving the control unit Additionally you can set each appliance LED to pulse when it receives a supervision poll normal operation details Self Test mode from the control unit allows on board sensors depending on the device type to detect their own strobe or horn output and report their status to the control unit Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously activated individually activated by applying a magnet Refer to the list of control unit data sheets for more Self Test information in Table 10 appliance Magnet Test this test mode the appliance LED pulses sequentially in response to the application of a magnet to conveniently indicate the appliance address appliance Magnet Testje this test mode after the address is indicated by pulsing the appliance LED the strobe briefly flashes and the horn briefly sounds to indicate correct Instrument Two TSIT second generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control unit Please contact your local Simplex representative for additional information addressable wiring isolator Model 4905 9929 Model 4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring to data sheet S4905 0001 device reports reference 2 Rev 2 11 2019 and Visible Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn and Strobe Model Series 49AV selection Visual A V appliances ES Addressable A V Appliance dimensions with cover 8 1 8 in H x 7 1 8 in W x 3 in D 206 mm x 180 mm x 76 mm color appliance only Select cover and separately instructions 1 Ceiling mount audible visual only V O appliances 2 Back boxes 3 S V covers required when ordering APPLC O models ALARM logo only 4 Wire guards and wire guard back boxes ceiling mount red wire guard ceiling mount red wire guard back box ES A V specifications 5 Environmental specifications application 23 VDC to 30 VDC to 151 or 40 to 66 DC control or strobe voltage range and ULC temperature rating CD W135 CD W185 CD and ULC temperature rating for and uncontrolled wet Public Mode 110 CD temperature rating and ULC humidity range The appliance covers and backboxes are available in red and white Do not paint or otherwise alter the factory finishes in any way to 120 or 40 to 49 non condensing at 140 or 60 for 18 AWG to 12 AWG or 0.82 mm2 to 3.31 mm2 to 120 or 0 to 49 6 Maximum RMS operating current mA mA mA mA mA mA mA mA mA Rev 2 11 2019

Related Files