Simplex Autocall 912H Series Analog Addressable Heat Detector - Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

ANALOG ADDRESSABLE DETECTOR Series Series Series Series Series Reporting of Reporting of Reporting of Reporting of Analog Reporting of Level Level Level Level Level Address in Address in Address in Detector Address in Address in Base Visible from Base Visible from Base Visible from Base Visible from Base Visible from Floor Floor Floor Floor Floor Service Service Service Complete Service Service Maintenance Maintenance Maintenance Maintenance Maintenance the Floor No the Floor No the Floor No the Floor No the Floor No Required Required Required Required Required Profile Profile Profile Low Profile Profile Design Design Design Attractive Design Design 4 4 4 4 Interchangeable 4 6 Bases 6 Bases 6 Bases 6 Bases 6 Bases for Fast for Fast for Fast for Fast Designed for Fast Easy Installation Easy Installation Easy Installation Easy Installation Easy Installation Alarm LED Alarm LED Alarm LED Integral Alarm LED Alarm LED Alarm LED Alarm LED Alarm LED Alarm LED Remote Alarm LED Wire Wire Wire Nonpolarized Wire Wire Temperature Temperature Temperature Temperature Two Temperature Locking Kit Locking Kit Locking Kit Optional Locking Kit Locking Kit Key Carrier 912H with 4 base 912H with 6 base Information Information Information Information Information 912H low profile heat detectors are for use in commercial industrial and installations The small size and of the detector make it an ideal for areas where aesthetics must be By selection of the configuration in the TFX series control panel the can be employed as either a 135 fixed temperature heat detector rate of rise heat detector or a 200 fixed temperature heat detector 912H detector uses two networked in a bridge configuration to pro a fast response that depends on both temperature and the change of rate of rise fixed temperature heat de can be used in areas where smoke are unsuitable due to environmental smoke dust etc Such areas kitchens locker rooms garages docks etc integral electronics emulate conven fire detector response curves and the state to a controller as an ana representation of the ambient tem conditions standby conditions the detector LED flashes periodically When an alarm is exceeded the detector LED steadily inch and six inch detector bases are A separate terminal on the detec base provides a voltage output for con to a remote LED Wiring connections nonpolarized for ease of installation un the remote LED output is used detector base includes a push button allows mounting the detector head in a position and permits testing of wiring with removing the detector head from the base detector head can be locked into posi with the optional locking device P N 515476 address information and commission date for the detector is stored in an on a separate address key An asso label carrier is used to identify the de address The address key and label are ordered separately from the detec The address keys are programmed using 900HP stand alone programmer or the CONSYS programmer address keys and label carrier are in the bottom of the detector head the detector head is installed and fully in the base the address keys and label are then transferred to the base If the head is removed from the base the key and label carrier remain in the detector address can be printed on the carrier and is visible from the floor It is necessary to ascend a ladder remove the from its base or to read a set of switches to determine the detector Detector heads may be removed replaced without system reprogramming the extract tools and test pole all and maintenance functions may be from the floor which reduces ser and routine maintenance costs Please catalog page 261 for more information detector accessories Approvals Approvals Approvals Approvals Approvals UL Listed File Number S675 ULC Listed File Number CS925 CSFM No 7270 1493 175 MEA No 176 99 E FM ID No 3004796 1 of 2 ADDRESSABLE DETECTOR Series Series Series Series Series 912H uses two matched ther in a bridge configuration to give rate of rise or fixed temperature re The thermal and electrical are designed in such a that the detector can be made to several models of heat detec without complex processing of the output thermistor is exposed to the air the other is thermally lagged in the detector body If the tempera is constant or only changing slowly thermistor temperatures will track air temperature and the signal will a function of air temperature Rapid in temperature such as those can occur in fires cause a tem difference to be established be the sensing and reference ther which compensates for the finite time of the sensing thermistor Voltage with AUTOCALL TFX series Current Average Current Average 5.6mA Temperature Listed Spacing installation temperature for 912H rises to 150 66 on intermediate setting to 100 to 37.8 noncondensing feet and AUTOCALL are trademarks of Tyco International Services AG or its affiliates in the US and or other countries 2 of 2

Related Files