Simplex Autocall Fire Alarm System TFX- AutoPlex - Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-autocall-fire-alarm-system-tfx-autoplex-data-sheet-5612784093.pdf |
---|---|
Type | |
Size | 1.36 MB |
Downloads |
Text Preview
FIRE ALARM SYSTEM Smoke and Smoke and Smoke and Smoke and Analog Smoke and Detection Detection Detection Detection Detection Addressable and and and and and Circuits Circuits Circuits Circuits Circuits Intelligence Intelligence Intelligence Local Intelligence Intelligence Degraded Mode Degraded Mode Degraded Mode Degraded Mode Degraded Mode Supervised Supervised Supervised Supervised Modular Supervised Supplies Supplies Supplies Supplies Supplies Character LCD Character LCD Character LCD Character LCD 80 Character LCD for Complete for Complete for Complete for Complete for Complete Diagnostics Diagnostics Diagnostics Diagnostics Diagnostics Verification Verification Verification Alarm Verification Verification Device Device Device Device Device Limited All Limited All Limited All Limited All Power Limited All Zonal or Group Zonal or Group Zonal or Group LED Zonal or Group Zonal or Group Option Option Option Option Option Detector Detector Detector Detector Smoke Detector Monitoring Monitoring Monitoring Monitoring Monitoring Automatic Automatic Automatic Automatic Automatic and and and and Automatic and Detector Detector Detector Detector Detector Information Information Information Information Information TFX AutoPlex is an ideal upgrade path installed AUTOCALL systems The TFX option communicates with the AL and other AUTOCALL systems through XA communications loop and provides the features of the AUTOCALL TFX fire alarm control panels Various pack options allow the TFX AutoPlex flexibil in form and function Used with the TFX 500M 800M or in a TFXnet Module TIM 500 or TIM 800 ap the TFX AutoPlex option can be in the same backbox with AL 1500 other AUTOCALL electronic modules TFX control unit is configured CONSYS configuration software TFX AutoPlex module is separately con to convert TFX zones or points into XA at the main control unit usually an or AL 1500E Since the TFX AutoPlex a TFX control panel or TIM it has its local intelligence and remains completely if the main control panel has failed a fault occurs in the XA communications Local input and output functions may configured at the TFX to take advantage this degrade mode capability TFX AutoPlex option features analog and heat detection with the 900 Series 550 Series detection devices These de provide the following capabilities and Alarm Reporting Utilizing TFX AutoPlex prior to reporting an alarm TFX or TIM may report an impending condition from a smoke detector which an amount of smoke which is unusual below the alarm threshold This added of response reduces the possibility of alarms resulting from cigarettes or low level sources of smoke and Manual Sensitivity Adjust 900 and 550 Series smoke detectors be configured to one of 6 sensitivity lev defined in percent per foot obscuration the TFX or TIM can be config to automatically shift detector sensitivity on time of day day of week and holidays Detector sensitivity is adjusted to actual building usage best performance Environmental Compensation TFX or TIM continuously monitors the smoke density at every analog and 550 Series detector As the mea density gradually shifts due to airborne and other environmental condi the alarm and prealarm thresholds of detector are individually adjusted to constant sensitivity Maximum de sensitivity is maintained with minimal for unwanted alarms Verification By Device 900 and 550 smoke detectors may be individually for an alarm verification se The verification sequence may be for operation per detector or per group of detectors for maxi system reliability Approvals Approvals Approvals Approvals Approvals UL 864 Listed File Number S2561 CSFM No 7165 1493 147 7170 1493 167 MEA No 415 92 E Vol III FM ID No OX2A8 AY 1 of 2 ALARM SYSTEM Maintenance The TFX or provides a warning signal at the control panel if a smoke detector become too contaminated to reliably its sensitivity Typically clean the detector will correct this condi from the Floor Almost all functions for 900 and 550 detectors including annual test sensitivity measurement removal installation can be performed from floor This reduces annual mainte cost and disruptions for the sys owner TFX or TIM features the RPS 424 modular regulated power supply rated 5 amps 24VDC Multiple power sup may be added to the system as to operate outputs such as noti appliance circuits Outputs are powered by the RPS 424 are power limited in accordance UL standard 864 and AUTOCALL are trademarks of Tyco International Services AG or its affiliates in the US and or other countries TEPG US a Tyco Company All rights reserved 2 of 2