Simplex Batteries and Chargers, 2081-9279, 110 Ah System Batteries and 2081-9280 Battery Cabinet

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Battery Cabinet and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery without charger 12 V 110 Ah rechargeable sealed lead acid battery Output terminals are high current posts connecting hardware is with battery cabinet Batteries have UL 924 recognized pressure relief valves Battery Cabinet ordered separately Use when fire alarm control panel internal charger is capable of 110 Ah batteries For compatible Simplex 4100ES 4100U systems connection requires wires to a 4100 5128 Battery Distribution Terminal Block located in cabinet For compatible 4100 Legacy systems wiring requires two wires for and two wires for battery connections Refer to data sheet S4081 0002 for 4100ES 4100U compatible battery with charger 110 Ah rechargeable sealed lead acid batteries provide and repeatable discharge and recharge characteristics for use fire alarm and other systems applications For use with Simplex fire control panels with battery chargers capable of up to 110 Ah these batteries in external battery cabinet 2081 9280 located to the control panel details connections two of these 12 V batteries in series to produce 24 V system Battery sets must be of identical voltage model number and approximately the same date of manufacture for operation chemicals and materials can be recycled Refer to information with the battery or on its case Return to the battery or to a similarly qualified battery processing facility for disposal 1 batteries 2 required for VDC system actual appearance may vary 2 Battery Cabinet capacity testing is recommended to be performed by using a lead acid battery tester designed to withdraw a minimum of charge Testing is available through your local Simplex product information to Installation Instructions 574 670 for Battery Cabinet installation See 4100ES basic panel data sheet S4100 1031 for the latest supply battery charger information reference Series Simplex battery chargers Power Supplies for Controller CPU Bays Additional ES Power Supply ES Additional SPS Additional EPS Additional EPS Remote Power Supply TrueAlert Addressable Supply TPS 4100 5113 4100 5313 4100 5327 4100 5127 4100 5122 4100 0114 Legacy power supplies Battery cabinet 2081 9280 has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7315 0026 144 for values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Westminster Rev 6 02 2021 and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery Cabinet without charger Included Protection Terminals weight per battery Voltage weight 1 2081 9280 Battery Cabinet 1 2 in W x 12 in H x 12 in D 673 mm x 305 mm x 305 mm and cables for compatibility with 2081 9279 batteries mounted fuseholder with 80 A fuse included AWG to 2 AWG 2 mm to 32 mm 49 lbs 22.2 kg with two batteries 213 lbs 97 kg 2 2081 9279 battery reference information 3 16 in W x 9 in H x 10 1 2 in D 284 mm x 230 mm x 267 mm Ah at 20 hour discharge rate V per battery 2 required for 24 V system currect terminal posts lbs 37 kg per battery with two batteries 213 lbs 97 kg wiring and 2081 9280 Battery Cabinet detail reference 3 wiring with 2081 9280 Battery Cabinet distance chart distance per battery discharge current range 3 Wiring distances wire mm2 A ft 8 m ft 12.5 m ft 20 m ft 32 m ft 51 m ft 81.7 m ft 130 m A ft 9.5 m ft 15 m ft 24 m ft 38 m ft 61 m ft 97.5 m A ft 10 ft 15.8 m ft 25 m ft 40 m ft 64 m A ft 11.9 m ft 19 m ft 30.5 m ft 48.7 m A ft 13.7 m ft 22 m ft 35 m A ft 17 m ft 27 m A ft 24 m Battery Cabinet additional wiring information battery cabinet output fuse is 80 A for battery protection battery fuse requirement To protect the output conductors install a line fuse rated properly to the load current in the battery plus of each output pair Wire per applicable local code Battery output connects to multiple conductor terminal block for connections to other panels requiring external battery power 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 6 02 2021

Related Files