Simplex Digital PBX

File Preview
File Preview
Click below to download for free

File Data

Name simplex-digital-pbx-3905621784.pdf
Type PDF
Size 765.27 KB
Downloads

Text Preview

TrueComTM Communications Systems ADIX Series 9012 9013 Digital Information Exchange 5195 is the latest microprocessor designed technology Digital solid state cross switches provide quiet reliable long life operation Simplex 5195 systems are available in three basic to provide a cost effective package that will with future user requirements The 5195 9011 and 9013 Controllers are designed to be used with Series Building Communications Intercom products Stand Alone or Full Network System Operation The supports the standard 5195 universal trunk station telephone cards system wide Call and Paging is provided when interfaced with 5100 Series Communication Systems Capacities Configuration Slot feature digital phones with optional display may be Each phone can have up to 32 user definable keys A budget digital Versa phone is available 8 user defined feature buttons 5195 is a stored program distributed control multi system utilizing digital speech paths based PMC32 time division multiplexing technology A host programming and operational features are supported the network Non blocking telephonic links the 5195 system ensure system wide access Integration Simplex Safety First is a lesson we live by Our solutions offer advanced TrueCom integration of 5195 PBX and 5100 intercom Utilizing the latest technology of Enhanced Caller ID CID transmits complete and accurate caller automatically Caller information appears on digital telephone LCD display including room number teacher name and room This is ideally suited for reporting emergencies urgent situations Full Digital Non Blocking Architecture Expandable Modular Design 128 Port Capacity with Optional Cabinets Full Feature Digital Telephones Flexible Numbering Plan Toll Restriction Optimized Routing Attendant and Administrative Coverage for and Night Mode Full Integration with 5199 Voice Mail and Intercom Systems Supports Caller ID on 5110 5115 5120 Ports and CID Trunks Built in Provisions for Battery Backup Optional Remote Programming and UL Listed FCC CSA and DOC Approved 5100 Integration Features All Call Zone Paging 2 Way Handsfree Room Intercom Master Time and Control Flexible Class Change Schedules Video Learning S5195 0003 1 ID 579 021 1 97 configurations vary from 2 to 16 ports with 14 to 100 hours of voice storage 5195 power supplies and field termination accessories UL 1459 listed The 5195 9193 system power supply an integral battery charger for direct DC battery By using two Simplex 33 AH batteries the following backup times may be attained normal usage hours hours 7 hours Simplex 4009 9802 Wall Mounted Battery Cabinet be used to house the batteries for printer output and station messaging detail are provided System wide tracking and logging detailed reporting of incoming outgoing calls to multiple 5100 systems through their ports and outside C O line access of long calls systems are equipped with four 4 relays for auxiliary functions operated manually from digital telephones Electronic background music standard in addition to auxiliary inputs for customized and music on hold applications DOS programming tool facilitates onsite programming Complete system database backup to floppy disk also provided with each system Remote maintenance out and DISA capabilities are available using the 5195 9901 Remote Maintenance Card Communications Systems same information can be simultaneously broadcast our wireless emergency notification system If an call goes unanswered for a specified time out digital voice ID is broadcast system wide through all of facility speakers announcing the room number that the emergency TrueCom 5100 integration operational features Video Learning Way Handsfree Room Intercom All Call Zone Paging Master Time and Control Flexible Class Change Schedules Telecom and Voice Mail Expansion Simplex 5195 9011 9012 9013 have the capability to expanded with the 5195 9112 Expansion shelf The and 9012 packages can have a maximum of two shelves providing a total system board slot of 16 Each expansion shelf provides six board The 5195 9011 9012 may be expanded by adding expansion shelves providing 12 additional board The 5195 9013 is packaged with two shelves and is to a single additional shelf or 6 additional board the modular approach of the Simplex 5195 ADIX today needs are cost effectively meet while still an avenue for future growth Voice Mail Integration 5195 fully integrates with Simplex 5199 Voice Mail Server Integrated features include Party ID Message Notification Integrated Call and Revert The 5199 is designed to streamline and information between parents and faculty in the K through Grade 12 environment from any Touch Tone Provided are such advanced features as Parent Student Messages Directory Lookup Homework Hotline Audio Bulletin Board Attendance Notification Multilingual Prompting Talking Grade Book Automated Attendant Communications Systems optional Ring Generator 5195 9937 is required for shelf housing a Single Line Telephone Single Line Lamp or OPX card Each telephone is via a two wire star wiring format A 9147 is provided with each of the three basic packages optional 5195 9914 DCDCM 48VDC Power Supply required on each shelf housing a ground start trunk Cards or E M Cards Power Supply Expansion Shelf the modular approach of the Simplex 5195 ADIX today needs are cost effectively provided while providing an avenue for future growth The Simplex and 9012 can add two additional expansion The 5195 9013 can add one additional expansion The 9112 Expansion Shelf provides and additional card slot or 48 ports Refer to back page for a pictorial on configuring card and port counts Specifications Common Module lbs Expansion Module Board Slots each Slots Specifications Parameters x W x D 15.5 x 19 x x W D 11.5 x 19 x 11.5 lbs x W x D 9.2 x 2.7 x 11 lbs One Per Shelf Division PCM32 Speech Slots 256 IX CPU16M Stored Program Multi Board 2 MB 1MB BTU hr maximum watts watts Capacity Capacity Dissipation 5195 9193 Input Input Voltage Tolerance 110V Tolerance Hz 63 Hz Input Current Simultaneous Ringing SLT Orbits Communications Systems Specifications Continue Generator Hz Backup power supplies include a battery interface Backup time dependent upon battery array system size and system Temperature Temperature Humidity non condensing Registration Numbers to 40qC to 104qF to 50qC to 122qF to 90 of Communications DOC Number 577 3326 A Interface Codes Start Trunks Start Trunks Tie Lines Lines Trunk Groups Trunk Groups Call Ringing Assignment 32 Stations Line for Software Versions 3.0 and higher delayed ringing assignment is not programmed Call Delayed Ringing Assignment Pick up Groups Hunt Groups Stations per Hunt Group Speed Dial Speed Dial Digits per Speed Dial Number Stations Stat

Related Files