Simplex E-Series Analog Heat Sensor 4098-9733E and Bases for Extended Exposure to High Humidity
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-e-series-analog-heat-sensor-4098-9733e-and-bases-for-extended-exposure-to-high-humidity-4752061893.pdf |
---|---|
Type | |
Size | 677.98 KB |
Downloads |
Text Preview
Listed FM Approved Addressable Initiating Peripherals E Series Analog Heat Sensor 4098 9733E and for Extended Exposure to High Humidity heat sensors provide analog thermal to the sensor base and feature Epoxy encapsulated electronic thermal sensor design gold plated contacts high humidity thermistor and steel screws A fast response thermistor that is inherently rate Operation for ceiling or wall mounting sensor bases features Digital transmission of analog sensor values via IDNet MAPNET II two wire communications Base mounted address remains with its location red LED for power on pulsing or alarm or steady on Locking anti tamper design mounts on standard box Designed for EMI compatibility Magnetically operated functional test options and accessories include Control of supervised or unsupervised remote relay Remote LED alarm indicator output Relays and LED alarm indicators Communications isolator base or sounder base alarm control panel provides Fixed temperature sensing rate of rise temperature or both Utility temperature sensing Automatic once per minute individual sensor calibration that verifies sensor integrity Ability to display and print detailed sensor information plain English language use with the following Simplex products 4007ES 4010 4010ES and 4100ES Series control and 4008 Series control panels with reduced set refer to data sheet S4008 0001 for details IDNet operation 4020 4100 and 4120 Series control panels Universal and 2120 TrueAlarm CDTs equipped MAPNET II operation listed to Standard 521 for 60 ft x 60 ft 18.3 m spacing for 135 F 57.2 C alarm 40 ft x 40 ft 12.2 m spacing for 155 F 68 C alarm Sounder operation is also listed to UL Standard 464 as audible notification appliance In most fires hazardous levels of smoke toxic gas can build up before a heat detection would initiate an alarm In cases where Life is a factor the use of smoke detection is highly This product was not ULC listed or approved by CSFM or MEA NYC or as of document date Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products Heat Sensor Mounted in Sounder Base Heat Sensor Mounted in Standard Size Base 4098 9733 heat sensors are self restoring and provide compensated fixed temperature sensing selectable or without rate of rise temperature sensing Due to small thermal mass the sensor thermistor accurately quickly measures the local temperature for analysis at fire alarm control panel Selection Rate of rise temperature is selectable at the control panel for either 15 F C or 20 F 11.1 C per minute Fixed temperature is independent of rate of rise sensing and to operate at 135 F 57.2 C or 155 F C In a slow developing fire the temperature may increase rapidly enough to operate the rate of rise However an alarm will be initiated when the reaches its rated fixed temperature setting Device Temperature Monitoring can be to monitor for temperature extremes in the from 32 F to 155 F 0 C to 68 C This feature provide freeze warnings or alert to HVAC system Refer to specific panels for availability Communication of Analog Sensing Sensor contain integral addressable electronics that monitor information from the detachable heat sensors sensor information is digitized and transmitted to system fire alarm control panel approximately every seconds using Simplex addressable communications panel processes the information to evaluate for pre alarm levels or other off normal conditions Alarm and Trouble LED Indication Each base LED pulses to indicate communications the panel If the control panel determines that a is in alarm or has some other type of trouble the are annunciated at the control panel and that sensor LED will be turned on steadily During a system the control panel will control the LEDs such that LED indicating a trouble will return to pulsing to help the alarmed sensors 1 2015 Application Reference sensor locations should be determined only after consideration of the physical layout and contents the area to be protected Refer to NFPA 72 the Fire Alarm and Signaling Code For detailed information refer to 4098 Detectors Sensors Bases Application Manual 574 709 LED Alarm Indicator bases located out of easy the 2098 9808 remote red alarm indicator duplicates the LED status indication It is on a single gang stainless plate for mounting on a standard box See illustration to the Mounting Reference Sensor and Base Mechanical Reference 4098 9733E is sealed against rear air flow entry and electronics are EMI RFI shielded Dimensions are in the illustrations below 164 mm 124 mm size base outline status indicator mm status mm boxes are supplied by others refer to notes below for additional information mount reference 102 mm box 102 mm box 38 mm box depth mount reference mount even with final or with up to 1 4 6.4 mm maximum recess Supervised mounts in base box or remotely Relay in base box Standard Size Base Mounting Adapter Plate required for mounting surface mounted boxes and 4 square flush box Size 2 1 2 X 1 1 2 X 1 3.75 inches 64 mm X 38 mm X 25.4 mm Supervised Relay in base electrical box or 2 3 8 X 1 1 4 X 11 32 in3 60.4 mm X 31.8 mm X 8.6 mm 4098 9789E 4098 9791E 4098 9792E and 4098 9780E Sounder Base Mounting 4098 9794E only when using 4 square box mount a single gang adapter plate RACO 787 or equal by others is required Adapter Plate required for mounting surface mounted boxes mounts inverted Base Heat Review wire size wire count box type and whether a locally mounted relay is used before determining box size When a locally mounted relay is used mount relay in electrical box and use 1 1 2 extension ring by others on square or octagonal box of 1 1 2 or 2 1 8 depth as required Flush mounting also fits a single gang box 2 1 8 51 mm deep if compatible with wiring requirements Not if a locally mounted relay is used 1 2015 E Series Heat Sensor Product Selection Chart Sensors Heat Sensor Bases Standard Sensor Base Base for use with IDNet only input is separated from output when communications short circuit occurs Base with wire connections for LED Alarm Indicator or Relay Sensor Relay Base with for Supervised Remote Relay connections for Remote Alarm or Unsupervised Relay relay is programmable and can be operated from control panel Sensor Relay Base with for Supervised Remote Relay connections for Remote Alarm or Unsupervised Relay relay is programmable and can be operated from control panel Base with built in piezoelectric sounder power can be from VDC or from a compatible NAC operation can be independently from the host control panel output can be synchronized via or by the NAC if NAC options available options available for use only Simplex models 4007ES 4008 4010ES 4100ES and 4100U alarm control panels Remote LED Alarm or 4098 9822 Relay Remote Relay Remote Alarm Indicator 4098 9822 Relay unsupervised Not compatible with 2120 CDT Supervised Remote Remote Alarm Indicator 4098 9822 Unsupervised Relay Not compatible with 2120 CDT R