Simplex Electronic Heat Detectors for Two-Wire Direct Connect

File Preview
File Preview
Click below to download for free

Text Preview

CSFM Listed FM Approved NYC Acceptance Initiating Peripherals Electronic Heat Detectors for Direct Connect thermal detection for protection of listed to Standard 521 temperature operation is suitable for most Thermistor based design is inherently rate due to minimal thermal lag Available for 135 F 57 C or 200 F 93 C UL spacing distance is 60 ft with rate of rise temperature detection Dual thermistor rate of rise operation For use where anticipated ambient temperature are less than 6 F minute UL spacing distance is 70 ft encapsulated electronic design provides Operation for ceiling or wall mounting Easily tested self restoring operation with repeatable Alarm indicating LED located on detector Current limited alarm that is compatible with initiating device circuits IDCs connecting design Wiring attaches directly to detector terminals Detector mounts onto mechanical adapter plate Electronic Design Simplex electronic detectors use a fast response thermistor based design provide temperature sensing that quickly accurately consistently identifies when fixed temperatures are The fixed temperature sensing thermistor tracks the local ambient temperature This the time required to melt a lead pellet or heat a element as occurs in mechanical heat detector and provides the required heat detection for most detection is determined by comparing thermistor responses By combining accurate with proper physical placement this patented detection design achieves a high level of not normally available with mechanical Direct Connect Heat Detector Range Current Current Operation Range to 32 VDC filtered DC with maximum ripple nominal to 100 mA maximum exact is determined by alarm limiting of connected FM requirements for between 15 and F min 8.33 and C min to 95 RH not intended outdoor applications to 140 F 18 C to 60 C diagram on page 2 Temperature Temperature Operating Range F Models F Models to 100 F 0 to 38 C to 150 F 0 to 68 C This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Accepted for use City of New York Department of Buildings MEA35 This product was not ULC listed as of document revision date Additional listings may applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection WARNING In most fires hazardous levels of smoke toxic gas can build up before a heat detection would initiate an alarm In cases where Life is a factor the use of smoke detection is highly 1 2015 Applications Reference detectors are used where property protection is desired where life safety protection is not required or is by other equipment Typical heat detector are satisfied by use of these fixed temperature detectors addition of rate of rise operation provides two forms of detection for use where temperature fluctuations are and are less than 6 F min 3.33 C min Where may fluctuate more quickly use fixed detection Fixed Temperature Guidelines F 57 C fixed temperature detectors are for temperatures that do not exceed 100 F 38 C F 93 C fixed temperature detectors are for temperatures that exceed 100 F 38 C but are than 150 F 66 C Indicating LED Operation heat detector LED turns ON continuously when in During normal conditions the LED is OFF Product Selection F C F C temperature with rate of rise Maximum Spacing ft x 60 ft 18.3 m x 18.3 m ft x 70 ft 21.3 m x 21.3 m Maximum Spacing ft X 15 ft 4.5 m x 4.5 m ft X 30 ft 9.1 m x 9.1 m temperature with rate of rise ft x 60 ft 18.3 m x 18.3 m ft x 70 ft 21.3 m x 21.3 m ft X 15 ft 4.5 m x 4.5 m ft X 30 ft 9.1 m x 9.1 m Installation Reference 102 mm octagonal box 38 mm deep minimum by others mount reference even with final or with up to 1 4 mm maximum recess mount reference 119 mm plate supplied mm detector assembly alarm indicator temperature sensing thermistor Refer to Installation Instructions 574 686 for additional information 1 2015 Applications Reference following table provides a reference for the rectangular area covered for detectors rated the given spacing For additional information consideration of ceiling height refer to 72 the National Fire Alarm Code Rectangular Area Dimensions For Single Detector Coverage ft Rated Spacing ft Rated Spacing ft Rated Spacing ft Rated Spacing m ft x 15 ft m x 4.5 m ft x 18.7 ft m x 5.7 m ft x 20.6 ft m x 6.2 m ft x 21.19 ft m x 6.4 m m ft x 30 ft m x 9.1 m ft x 34.2 ft m x 10.4 m ft x 37.4 ft m x 11.4 m ft x 39.7 ft m x 12.1 m ft x 41.2 ft m x 12.5 m ft x 42.1 ft m x 12.8 m ft x 42.4 ft m x 12.9 m 18.3 m ft x 60 ft m x 18.3 m ft x 64.6 ft m x 19.7 m ft x 68.5 ft m x 20.8 m ft x 72 ft m x 21.9 m ft x 74.8 ft m x 22.8 m ft x 77.3 ft m x 23.5 m ft x 79.3 ft m x 24.1 m ft x 81 ft m x 24.7 m ft x 82.4 ft m x 25.1 m ft x 83.5 ft m x 25.4 m ft x 84.2 ft m x 25.6 m ft x 84.7 ft m x 25.8 ft x 84.85 ft m x 25.8 m m ft x 70 ft m x 21.3 m ft x 74.6 ft m x 22.7 m ft x 78.7 ft m x 24 m ft x 82.3 ft m x 25 m ft x 85.4 ft m x 26 m ft x 88.1 ft m x 26.8 m ft x 90.5 ft m x 27.5 m ft x 92.6 ft m x 28.2 m ft x 94.3 ft m x 28.7 m ft x 95.7 ft m x 29.1 m ft x 96.9 ft m x 29.5 m ft x 97.8 ft m x 29.8 m ft x 98.4 ft m x 30 m ft x 98.8 ft m x 30.1 m ft x 99 ft m x 30.2 m 1 2015 SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Code are registered trademarks of the National Fire Protection Association NFPA Fire Protection Products Westminster MA 01441 0001 USA 1 2015 2015 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice

Related Files