Simplex ES Network ES Net Network Applications, Communications, Options and Specifications

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet ES Network Net Network Applications Communications Options and Specifications ULC CSFM Listed Net features Network ES Net is a high bandwidth 100 Mbps IP based fire alarm that supports up to 99 nodes and uses industry standard technology and infrastructure for greater design and installation wide system upgrades from a single point Net allows for software updates to be applied to all network nodes a single download The high bandwidth ES Net network can software updates to all 99 nodes from a single location at node on the network in minutes increasing system up time and business interruptions 4120 fire network migrations the TrueSite Workstation to integrate ES Net installations with 4120 networks This allows a phased migration path for existing In some cases existing network infrastructure and cabling be reused to lower the migration cost of ES Net migrations appliance synchronization the Network Sync feature to synchronize all notification appliances a single loop of up to 99 nodes Network Sync requires a network topology where all sync nodes be within a maximum distance of 30 nodes from the designated Sync Node MSN if using Ethernet or Fiber and 10 nodes if DSL Refer to your control unit s programmer manual for further diagnostics Net provides advanced network diagnostic tools and reports that easy to read Detailed information about network communication and status is available allowing technicians to pinpoint problems reduce the time required to troubleshoot network communication increased bandwidth and traffic speeds compared to fire networks Net is an IP based network which has greatly increased bandwidth to traditional fire networks Every node that is part of a can be notified about network events cable 1 Typical ES Net traffic speeds traffic rate megabits per second Mbps or better Mbps single mode or multi fiber media Mbps to 12 Mbps depending on with 18 AWG cabling 2 Mbps in ULC mode 1 ES Net example Net overview Net fire alarm control units FACUs provide extensive installation and service features with point and module capacities suitable a wide range of system applications and large multi site installations FACUs and devices 4100ES 4010ES and 4007ES series FACUs 4100ES network display units NDU 4190 series TrueSite Workstations and Incident Commanders Net network configuration Net supports multiple Class X loops and or Class B linear network See ES Net network multi topology support ES Net node requires an ES Net Network Interface Card NIC to and receive data on the network in some cases optional network cards may be required You can configure the network to share and control functions between nodes ES NICs on each node connect in a point to point arrangement security and fault tolerance to the network This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 0026 0323 7165 0026 0251 7165 0026 0369 and 7165 0026 0378 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable your local Simplex product supplier for the latest status Refer to Product Selection tables for specific UL and ULC listing details Listings and approvals under Simplex Time Recorder Co are the of Tyco Fire Protection Products S4100 0076 Rev 12 2 2022 Net Network Applications Communications Options and Specifications Error reporting and historical data on some error conditions is available network diagnostics tool diagnoses the following errors on the ES from an ES control unit or TSW Link down Mis wired links Ground fault Version control mismatch between nodes Extra node in network Duplicate node in network Missing node Non sync nodes Net and 4120 network comparison Table 2 to determine when to select ES Net versus 4120 network alarm products based on the key features of each network For 4120 network equipment reference refer to datasheet and associated network product datasheets see 2 ES Net and 4120 network feature comparison Net bandwidth IP based network 100 Mbps speed download to all nodes network diagnostics connection download to all nodes 4100ES 4010ES 4007ES and NSI node support node support appliance synchronization over the appliance synchronization within a unit number of ES Net versus 4120 network for each TSW TrueSite Workstation supports up to seven ES loops or up to seven 4120 loops or up to seven total in any combination of ES Net and 4120 X network communications B network communications no T tapping B network communications with T tapping support bridge support fiber modem support supports both dedicated fire alarm LAN and LAN connections redundant CPU support traffic support For ES Net networks the maximum number of nodes between MSN and a sync node must not exceed 30 nodes if using Ethernet Fiber and 10 nodes if using DSL Refer to your control unit s pro manual for further information resilience Net is resilient to failures and can detect degraded and non paths between any two connected nodes network options Support for multiple Class X loops or multiple Class B linear network m or less Ethernet communications with Cat 5e cable or better for runs of 328 ft Fiber media communications with multi mode or single mode fiber providing increased noise immunity and longer distances runs of up to 82,000 ft 25 km with single mode fiber Wired communications with a single wire pair between nodes using bandwidth DSL media cards for existing installations where or fiber are not available up to 15,000 ft 4572 m with 18 unshielded twisted pair wire Workstation and Incident Commander nodes TrueSite Workstation or Incident Commander supports multiple ES Net of up to 99 nodes TrueSite Workstation node can attach to seven network loops in any of ES Net and 4120 loops Incident Commander node can attach to seven network loops up to ES Net loops and two 4120 loops information UL 864 Fire Detection and Control UOJZ Smoke Control Service Releasing Device Service SYZV UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 UL 1610 as Central Station Burglar Alarm Control Unit AMCX Net software features Programmer Net communications allows technicians to build and download a job from one location to all FACUs on the network in a single Typical download time to a full ring of 99 nodes is 5 minutes less and requires ethernet or fiber optics media file transfer and firmware updates are critically important on a FACU The IP file transfer tool automatically discovers ES Net NIC connected to the ES Net network and suggests executive and updates where applicable You can update ES FACU runtime and secondary cards from anywhere on the network diagnostics advanced network diagnostic tool allows simple and accurate of network communication issues performance issues and connections from any node on the ES network You can run test for any control unit from any point on the network network diagnostic tool supports multiple remote terminal sessions ES control unit nodes and provides information on network status topology and attendance in the ES network Historical port statistics as operational parameters and errors for each port are stored for 2 S4100 0076 Rev 12 2 2022

Related Files